ORCID Profile
0000-0002-6635-2303
Does something not look right? The information on this page has been harvested from data sources that may not be up to date. We continue to work with information providers to improve coverage and quality. To report an issue, use the Feedback Form.
Publisher: Springer Science and Business Media LLC
Date: 05-2014
DOI: 10.1038/JES.2013.20
Abstract: Personal activity patterns have often been suggested as a source of unexplained variability when comparing personal particulate matter (PM2.5) exposure to modeled data using central site or microenvironmental data. To characterize the effect of personal activity patterns on asthmatic children's personal PM2.5 exposure, data from the Windsor, Ontario Exposure Assessment Study were analyzed. The children spent on an average 67.1±12.7% (winter) and 72.3±22.6% (summer) of their time indoors at home where they received 51.7±14.8% and 66.3±19.0% of their PM2.5 exposure, respectively. In winter, 17.7±5.9% of their time was spent at school where they received 38.6±11.7% of their PM2.5 exposure. In summer, they spent 10.3±11.8% 'indoors away from home', which represented 23.4±18.3% of their PM2.5 exposure. Personal activity codes adapted from those of the National Human Activity Pattern Survey and the Canadian Human Activity Pattern Survey were assigned to the children's activities. Of the over 100 available activity codes, 19 activities collectively encompassed nearly 95% of their time. Generalized estimating equation (GEE) models found that, while indoors at home, relative to daytime periods when sedentary activities were conducted, several personal activities were associated with significantly elevated personal PM2.5 exposures. Indoor playing represented a mean increase in PM2.5 of 10.1 μg/m(3) (95% CI 6.3-13.8) and 11.6 μg/m(3) (95% CI 8.1-15.1) in winter and summer, respectively, as estimated by a personal nephelometer.
Publisher: Informa UK Limited
Date: 02-2011
DOI: 10.3155/1047-3289.61.2.142
Abstract: The Windsor, Ontario Exposure Assessment Study evaluated the contribution of ambient air pollutants to personal and indoor exposures of adults and asthmatic children living in Windsor, Ontario, Canada. In addition, the role of personal, indoor, and outdoor air pollution exposures upon asthmatic children's respiratory health was assessed. Several active and passive s ling methods were applied, or adapted, for personal, indoor, and outdoor residential monitoring of nitrogen dioxide, volatile organic compounds, particulate matter (PM PM ≤2.5 μm [PM
Publisher: Elsevier BV
Date: 12-2011
Publisher: Hindawi Limited
Date: 11-01-2014
DOI: 10.1111/INA.12084
Abstract: Indoor fine particles (FPs) are a combination of ambient particles that have infiltrated indoors, and particles that have been generated indoors from activities such as cooking. The objective of this paper was to estimate the infiltration factor (Finf ) and the ambient/non-ambient components of indoor FPs. To do this, continuous measurements were collected indoors and outdoors for seven consecutive days in 50 non-smoking homes in Halifax, Nova Scotia in both summer and winter using DustTrak (TSI Inc) photometers. Additionally, indoor and outdoor gravimetric measurements were made for each 24-h period in each home, using Harvard impactors (HI). A computerized algorithm was developed to remove (censor) peaks due to indoor sources. The censored indoor/outdoor ratio was then used to estimate daily Finfs and to determine the ambient and non-ambient components of total indoor concentrations. Finf estimates in Halifax (daily summer median = 0.80 daily winter median = 0.55) were higher than have been reported in other parts of Canada. In both winter and summer, the majority of FP was of ambient origin (daily winter median = 59% daily summer median = 84%). Predictors of the non-ambient component included various cooking variables, combustion sources, relative humidity, and factors influencing ventilation. This work highlights the fact that regional factors can influence the contribution of ambient particles to indoor residential concentrations. Ambient and non-ambient particles have different risk management approaches, composition, and likely toxicity. Therefore, a better understanding of their contribution to the indoor environment is important to manage the health risks associated with fine particles (FPs) effectively. As well, a better understanding of the factors Finf can help improve exposure assessment and contribute to reduced exposure misclassification in epidemiologic studies.
Publisher: Elsevier BV
Date: 04-2011
Publisher: Hindawi Limited
Date: 31-12-2015
DOI: 10.1111/INA.12171
Publisher: Elsevier BV
Date: 09-2014
Publisher: Elsevier BV
Date: 12-2012
Publisher: Elsevier BV
Date: 12-2011
Publisher: Hindawi Limited
Date: 19-10-2015
DOI: 10.1111/INA.12252
Abstract: Traffic emissions have been associated with a wide range of adverse health effects. Many schools are situated close to major roads, and as children spend much of their day in school, methods to reduce traffic-related air pollutant concentrations in the school environment are warranted. One promising method to reduce pollutant concentrations in schools is to alter the timing of the ventilation so that high ventilation time periods do not correspond to rush hour traffic. Health Canada, in collaboration with the Ottawa-Carleton District School Board, tested the effect of this action by collecting traffic-related air pollution data from four schools in Ottawa, Canada, during October and November 2013. A baseline and intervention period was assessed in each school. There were statistically significant (P < 0.05) reductions in concentrations of most of the pollutants measured at the two late-start (9 AM start) schools, after adjusting for outdoor concentrations and the absolute indoor-outdoor temperature difference. The intervention at the early-start (8 AM start) schools did not have significant reductions in pollutant concentrations. Based on these findings, changing the timing of the ventilation may be a cost-effective mechanism of reducing traffic-related pollutants in late-start schools located near major roads.
Publisher: Hindawi Limited
Date: 20-09-2016
DOI: 10.1111/INA.12321
Abstract: Previous research has shown that indoor benzene levels in homes with attached garages are higher than homes without attached garages. Exhaust ventilation in attached garages is one possible intervention to reduce these concentrations. To evaluate the effectiveness of this intervention, a randomized crossover study was conducted in 33 Ottawa homes in winter 2014. VOCs including benzene, toluene, ethylbenzene, and xylenes, nitrogen dioxide, carbon monoxide, and air exchange rates were measured over four 48-hour periods when a garage exhaust fan was turned on or off. A blower door test conducted in each garage was used to determine the required exhaust fan flow rate to provide a depressurization of 5 Pa in each garage relative to the home. When corrected for ambient concentrations, the fan decreased geometric mean indoor benzene concentrations from 1.04 to 0.40 μg/m
Publisher: American Chemical Society (ACS)
Date: 10-10-2014
DOI: 10.1021/ES503144H
Abstract: Residential wood combustion is an important source of ambient air pollution, accounting for over 25% of fine particulate matter (PM2.5) emissions in Canada. In addition to these ambient contributions, wood smoke pollutants can enter the indoor environment directly when loading or stoking stoves, resulting in a high potential for human exposure. A study of the effectiveness of air cleaners at reducing wood smoke-associated PM2.5 of indoor and outdoor origin was conducted in 31 homes during winter 2009-10. Day 1, the residents' wood burning appliance operated as usual with no air cleaner. Days 2 and 3, the wood burning appliance was not operational and the air cleaner was randomly chosen to operate in "filtration" or "placebo filtration" mode. When the air cleaner was operating, total indoor PM2.5 levels were significantly lower than on placebo filtration days (p = 0.0001) resulting in a median reduction of 52%. There was also a reduction in the median PM2.5 infiltration factor from 0.56 to 0.26 between these 2 days, suggesting the air cleaner was responsible for increased PM2.5 deposition on filtration days. Our findings suggest that the use of an air cleaner reduces exposure to indoor PM2.5 resulting from both indoor and ambient wood smoke sources.
Publisher: MDPI AG
Date: 16-08-2010
Publisher: American Chemical Society (ACS)
Date: 06-11-2013
DOI: 10.1021/ES402580T
Abstract: Human exposure to particles depends on particle loss mechanisms such as deposition and filtration. Fine and ultrafine particles (FP and UFP) were measured continuously over seven consecutive days during summer and winter inside 74 homes in Edmonton, Canada. Daily average air exchange rates were also measured. FP were also measured outside each home and both FP and UFP were measured at a central monitoring station. A censoring algorithm was developed to identify indoor-generated concentrations, with the remainder representing particles infiltrating from outdoors. The resulting infiltration factors were employed to determine the continuously changing background of outdoor particles infiltrating the homes. Background-corrected indoor concentrations were then used to determine rates of removal of FP and UFP following peaks due to indoor sources. About 300 FP peaks and 400 UFP peaks had high-quality (median R(2) value >98%) exponential decay rates lasting from 30 min to 10 h. Median (interquartile range (IQR)) decay rates for UFP were 1.26 (0.82-1.83) h(-1) for FP 1.08 (0.62-1.75) h(-1). These total decay rates included, on average, about a 25% contribution from air exchange, suggesting that deposition and filtration accounted for the major portion of particle loss mechanisms in these homes. Models presented here identify and quantify effects of several factors on total decay rates, such as window opening behavior, home age, use of central furnace fans and kitchen and bathroom exhaust fans, use of air cleaners, use of air conditioners, and indoor-outdoor temperature differences. These findings will help identify ways to reduce exposure and risk.
Publisher: Informa UK Limited
Date: 12-05-2011
Publisher: American Chemical Society (ACS)
Date: 22-05-2015
Abstract: Exposure to submicron particles (PM1) is of interest due to their possible chronic and acute health effects. Seven consecutive 24-h PM1 s les were collected during winter and summer 2010 in a total of 74 nonsmoking homes in Edmonton, Canada. Median winter concentrations of PM1 were 2.2 μg/m(3) (interquartile range, IQR = 0.8-6.1 μg/m(3)) and 3.3 μg/m(3) (IQR = 1.5-6.9 μg/m(3)) for indoors and outdoors, respectively. In the summer, indoor (median 4.4 μg/m(3), IQR = 2.4-8.6 μg/m(3)) and outdoor (median 4.3 μg/m(3), IQR = 2.6-7.4 μg/m(3)) levels were similar. Positive matrix factorization (PMF) was applied to identify and apportion indoor and outdoor sources of elements in PM1 mass. Nine sources contributing to both indoor and outdoor PM1 concentrations were identified including secondary sulfate, soil, biomass smoke and environmental tobacco smoke (ETS), traffic, settled and mixed dust, coal combustion, road salt/road dust, and urban mixture. Three additional indoor sources were identified i.e., carpet dust, copper-rich, and silver-rich. Secondary sulfate, soil, biomass smoke and ETS contributed more than 70% (indoors: 0.29 μg/m(3), outdoors: 0.39 μg/m(3)) of measured elemental mass in PM1. These findings can aid understanding of relationships between submicron particles and health outcomes for indoor/outdoor sources.
Publisher: Elsevier BV
Date: 08-2015
Publisher: Springer Science and Business Media LLC
Date: 26-05-2010
DOI: 10.1038/JES.2010.15
Abstract: Continuous monitors can be used to supplement traditional filter-based methods of determining personal exposure to air pollutants. They have the advantages of being able to identify nearby sources and detect temporal changes on a time scale of a few minutes. The Windsor Ontario Exposure Assessment Study (WOEAS) adopted an approach of using multiple continuous monitors to measure indoor, outdoor (near-residential) and personal exposures to PM₂.₅, ultrafine particles and black carbon. About 48 adults and households were s led for five consecutive 24-h periods in summer and winter 2005, and another 48 asthmatic children for five consecutive 24-h periods in summer and winter 2006. This article addresses the laboratory and field validation of these continuous monitors. A companion article (Wheeler et al., 2010) provides similar analyses for the 24-h integrated methods, as well as providing an overview of the objectives and study design. The four continuous monitors were the DustTrak (Model 8520, TSI, St. Paul, MN, USA) and personal DataRAM (pDR) (ThermoScientific, Waltham, MA, USA) for PM₂.₅ the P-Trak (Model 8525, TSI) for ultrafine particles and the Aethalometer (AE-42, Magee Scientific, Berkeley, CA, USA) for black carbon (BC). All monitors were tested in multiple co-location studies involving as many as 16 monitors of a given type to determine their limits of detection as well as bias and precision. The effect of concentration and electronic drift on bias and precision were determined from both the collocated studies and the full field study. The effect of rapid changes in environmental conditions on switching an instrument from indoor to outdoor s ling was also studied. The use of multiple instruments for outdoor s ling was valuable in identifying occasional poor performance by one instrument and in better determining local contributions to the spatial variation of particulate pollution. Both the DustTrak and pDR were shown to be in reasonable agreement (R² of 90 and 70%, respectively) with the gravimetric PM₂.₅ method. Both instruments had limits of detection of about 5 μg/m³. The DustTrak and pDR had multiplicative biases of about 2.5 and 1.6, respectively, compared with the gravimetric s lers. However, their average bias-corrected precisions were <10%, indicating that a proper correction for bias would bring them into very good agreement with standard methods. Although no standard methods exist to establish the bias of the Aethalometer and P-Trak, the precision was within 20% for the Aethalometer and within 10% for the P-Trak. These findings suggest that all four instruments can supply useful information in environmental studies.
Publisher: Elsevier BV
Date: 08-2014
Publisher: Informa UK Limited
Date: 03-2011
DOI: 10.3155/1047-3289.61.3.324
Abstract: The Windsor, Ontario Exposure Assessment Study evaluated the contribution of ambient air pollutants to personal and indoor exposures of adults and asthmatic children living in Windsor, Ontario, Canada. In addition, the role of personal, indoor, and outdoor air pollution exposures upon asthmatic children's respiratory health was assessed. Several active and passive s ling methods were applied, or adapted, for personal, indoor, and outdoor residential monitoring of nitrogen dioxide, volatile organic compounds, particulate matter (PM PM ≤ 2.5 μm [PM
Location: United States of America
Location: United States of America
No related grants have been discovered for Lance Wallace.