ORCID Profile
0000-0001-6529-911X
Current Organisation
University of North Carolina at Chapel Hill
Does something not look right? The information on this page has been harvested from data sources that may not be up to date. We continue to work with information providers to improve coverage and quality. To report an issue, use the Feedback Form.
Publisher: IOP Publishing
Date: 10-04-2012
DOI: 10.1088/1741-2560/9/3/036001
Abstract: An implantable micromachined neural probe with multichannel electrode arrays for both neural signal recording and electrical stimulation was designed, simulated and experimentally validated for deep brain stimulation (DBS) applications. The developed probe has a rough three-dimensional microstructure on the electrode surface to maximize the electrode-tissue contact area. The flexible, polyimide-based microelectrode arrays were each composed of a long shaft (14.9 mm in length) and 16 electrodes (5 µm thick and with a diameter of 16 µm). The ability of these arrays to record and stimulate specific areas in a rat brain was evaluated. Moreover, we have developed a finite element model (FEM) applied to an electric field to evaluate the volume of tissue activated (VTA) by DBS as a function of the stimulation parameters. The signal-to-noise ratio ranged from 4.4 to 5 over a 50 day recording period, indicating that the laboratory-designed neural probe is reliable and may be used successfully for long-term recordings. The somatosensory evoked potential (SSEP) obtained by thalamic stimulations and in vivo electrode-electrolyte interface impedance measurements was stable for 50 days and demonstrated that the neural probe is feasible for long-term stimulation. A strongly linear (positive correlation) relationship was observed among the simulated VTA, the absolute value of the SSEP during the 200 ms post-stimulus period (ΣSSEP) and c-Fos expression, indicating that the simulated VTA has perfect sensitivity to predict the evoked responses (c-Fos expression). This laboratory-designed neural probe and its FEM simulation represent a simple, functionally effective technique for studying DBS and neural recordings in animal models.
Publisher: SAGE Publications
Date: 04-04-2012
Abstract: Optical imaging of changes in total hemoglobin concentration ( HbT), cerebral blood volume ( CBV), and hemoglobin oxygen saturation ( SO 2 ) provides a means to investigate brain hemodynamic regulation. However, high-resolution transcranial imaging remains challenging. In this study, we applied a novel functional photoacoustic microscopy technique to probe the responses of single cortical vessels to left forepaw electrical stimulation in mice with intact skulls. Functional changes in HbT, CBV, and SO 2 in the superior sagittal sinus and different-sized arterioles from the anterior cerebral artery system were bilaterally imaged with unambiguous 36 × 65- μm 2 spatial resolution. In addition, an early decrease of SO 2 in single blood vessels during activation (i.e., ‘the initial dip’) was observed. Our results indicate that the initial dip occurred specifically in small arterioles of activated regions but not in large veins. This technique complements other existing imaging approaches for the investigation of the hemodynamic responses in single cerebral blood vessels.
Publisher: SPIE-Intl Soc Optical Eng
Date: 07-05-2012
Publisher: Elsevier BV
Date: 15-08-2010
DOI: 10.1016/J.NEUROIMAGE.2010.03.065
Abstract: The present study reported the development of a novel functional photoacoustic microscopy (fPAM) system for investigating hemodynamic changes in rat cortical vessels associated with electrical forepaw stimulation. Imaging of blood optical absorption by fPAM at multiple appropriately-selected and distinct wavelengths can be used to probe changes in total hemoglobin concentration (HbT, i.e., cerebral blood volume [CBV]) and hemoglobin oxygen saturation (SO(2)). Changes in CBV were measured by images acquired at a wavelength of 570nm (lambda(570)), an isosbestic point of the molar extinction spectra of oxy- and deoxy-hemoglobin, whereas SO(2) changes were sensed by pixel-wise normalization of images acquired at lambda(560) or lambda(600) to those at lambda(570). We demonstrated the capacity of the fPAM system to image and quantify significant contralateral changes in both SO(2) and CBV driven by electrical forepaw stimulation. The fPAM system complements existing imaging techniques, with the potential to serve as a favorable tool for explicitly studying brain hemodynamics in animal models.
Location: United States of America
Location: United States of America
No related grants have been discovered for Yen-Yu Ian Shih.