ORCID Profile
0000-0002-1148-179X
Current Organisations
University of Oxford
,
University College London
Does something not look right? The information on this page has been harvested from data sources that may not be up to date. We continue to work with information providers to improve coverage and quality. To report an issue, use the Feedback Form.
Publisher: Wiley
Date: 11-06-2018
Publisher: IOP Publishing
Date: 24-02-2017
Abstract: The aim of this study was to characterize the behaviour of superparamagnetic particles in magnetic drug targeting (MDT) schemes. A 3-dimensional mathematical model was developed, based on the analytical derivation of the trajectory of a magnetized particle suspended inside a fluid channel carrying laminar flow and in the vicinity of an external source of magnetic force. Semi-analytical expressions to quantify the proportion of captured particles, and their relative accumulation (concentration) as a function of distance along the wall of the channel were also derived. These were expressed in terms of a non-dimensional ratio of the relevant physical and physiological parameters corresponding to a given MDT protocol. The ability of the analytical model to assess magnetic targeting schemes was tested against numerical simulations of particle trajectories. The semi-analytical expressions were found to provide good first-order approximations for the performance of MDT systems in which the magnetic force is relatively constant over a large spatial range. The numerical model was then used to test the suitability of a range of different designs of permanent magnet assemblies for MDT. The results indicated that magnetic arrays that emit a strong magnetic force that varies rapidly over a confined spatial range are the most suitable for concentrating magnetic particles in a localized region. By comparison, commonly used magnet geometries such as button magnets and linear Halbach arrays result in distributions of accumulated particles that are less efficient for delivery. The trajectories predicted by the numerical model were verified experimentally by acoustically focusing magnetic microbeads flowing in a glass capillary channel, and optically tracking their path past a high field gradient Halbach array.
Publisher: Wiley
Date: 07-08-2019
Publisher: IOP Publishing
Date: 04-05-2016
Publisher: IOP Publishing
Date: 05-09-2017
Abstract: Ultrasound and microbubbles have been shown to accelerate the breakdown of blood clots both in vitro and in vivo. Clinical translation of this technology is still limited, however, in part by inefficient microbubble delivery to the thrombus. This study examines the obstacles to delivery posed by fluid dynamic conditions in occluded vasculature and investigates whether magnetic targeting can improve microbubble delivery. A 2D computational fluid dynamic model of a fully occluded Y-shaped microarterial bifurcation was developed to determine: (i) the fluid dynamic field in the vessel with inlet velocities from 1-100 mm s
Publisher: IOP Publishing
Date: 12-10-2015
DOI: 10.1088/0031-9155/60/21/8303
Abstract: A key challenge in the development of magnetic drug targeting (MDT) as a clinically relevant technique is designing systems that can apply sufficient magnetic force to actuate magnetic drug carriers at useful tissue depths. In this study an optimisation routine was developed to generate designs of Halbach arrays consisting of multiple layers of high grade, cubic, permanent magnet elements, configured to deliver the maximum pull or push force at a position of interest between 5 and 50 mm from the array, resulting in arrays capable of delivering useful magnetic forces to depths past 20 mm. The optimisation routine utilises a numerical model of the magnetic field and force generated by an arbitrary configuration of magnetic elements. Simulated field and force profiles of optimised arrays were evaluated, also taking into account the forces required for assembling the array in practice. The resultant selection for the array, consisting of two layers, was then constructed and characterised to verify the simulations. Finally the array was utilised in a set of in vitro experiments to demonstrate its capacity to separate and retain microbubbles loaded with magnetic nanoparticles against a constant flow. The optimised designs are presented as light-weight, inexpensive options for applying high-gradient, external magnetic fields in MDT applications.
Publisher: Elsevier BV
Date: 05-2019
DOI: 10.1016/J.ULTRASMEDBIO.2018.12.014
Abstract: Microbubble-enhanced sonothrombolysis is a promising approach to increasing the tolerability and efficacy of current pharmacological treatments for ischemic stroke. Maintaining therapeutic concentrations of microbubbles and drugs at the clot site, however, poses a challenge. The objective of this study was to investigate the effect of magnetic microbubble targeting upon clot lysis rates in vitro. Retracted whole porcine blood clots were placed in a flow phantom of a partially occluded middle cerebral artery. The clots were treated with a combination of tissue plasminogen activator (0.75 µg/mL), magnetic microbubbles (∼10
Location: United Kingdom of Great Britain and Northern Ireland
Location: United Kingdom of Great Britain and Northern Ireland
No related grants have been discovered for Dario Carugo.