Abstract: Adverse neurological events associated with left ventricular assist devices (LVADs) have been suspected to be related to thrombosis. This study aimed to understand the risks of thrombosis with variations in the implanted device orientation. A severely dilated pulsatile patient-specific left ventricle, modelled with computational fluid dynamics, was utilised to identify the risk of thrombosis for five cannulation angles. With respect to the inflow cannula axis directed towards the mitral valve, the other angles were 25° and 20° towards the septum and 20° and 30° towards the free wall. Inflow cannula angulation towards the free wall resulted in longer blood residence time within the ventricle, slower ventricular washout and reduced pulsatility indices along the septal wall. Based on the model, the ideal inflow cannula alignment to reduce the risk of thrombosis was angulation towards the mitral valve and up to parallel to the septum, avoiding the premature clearance of incoming blood. This study indicates the potential effects of inflow cannulation angles and may guide optimised implantation configurations however, the ideal approach will be influenced by other patient factors and is suspected to change over the course of support.
Publisher: Wiley
Date: 08-07-2022
Abstract: Engineered tissues provide an alternative to graft material, circumventing the use of donor tissue such as autografts or allografts and non‐physiological synthetic implants. However, their lack of vasculature limits the growth of volumetric tissue more than several millimeters thick which limits their success post‐implantation. Perfused bioreactors enhance nutrient mass transport inside lab‐grown tissue but remain poorly customizable to support the culture of personalized implants. Here, a multiscale framework of computational fluid dynamics (CFD), additive manufacturing, and a perfusion bioreactor system are presented to engineer personalized volumetric tissue in the laboratory. First, microscale 3D printed scaffold pore geometries are designed and 3D printed to characterize media perfusion through CFD and experimental fluid testing rigs. Then, perfusion bioreactors are custom‐designed to combine 3D printed scaffolds with flow‐focusing inserts in patient‐specific shapes as simulated using macroscale CFD. Finally, these computationally optimized bioreactor‐scaffold assemblies are additively manufactured and cultured with pre‐osteoblast cells for 7, 20, and 24 days to achieve tissue growth in the shape of human calcaneus bones of 13 mL volume and 1 cm thickness. This framework enables an intelligent model‐based design of 3D printed scaffolds and perfusion bioreactors which enhances nutrient transport for long‐term volumetric tissue growth in personalized implant shapes. The novel methods described here are readily applicable for use with different cell types, biomaterials, and scaffold microstructures to research therapeutic solutions for a wide range of tissues.
Publisher: MDPI AG
Date: 03-05-2022
Abstract: Over the past decade, the use of AR has significantly increased over a wide range of applications. Although there are many good ex les of AR technology being used in engineering, retail, and for entertainment, the technology has not been widely adopted for teaching in university engineering departments. It is generally accepted that the use of AR can complement the students’ learning experience by improving engagement and by helping to visualise complex engineering physics however, several key challenges still have to be addressed to fully integrate the use of AR into a broader engineering curriculum. The presented paper reviews the uses of AR in engineering education, highlights the benefits of AR integration in engineering curriculums, as well as the barriers that are preventing its wider adoption.
Publisher: Elsevier BV
Date: 04-2018
DOI: 10.1016/J.JBIOMECH.2018.02.038
Abstract: Left ventricular assist devices are associated with thromboembolic events, which are potentially caused by altered intraventricular flow. Due to patient variability, differences in apical wall thickness affects cannula insertion lengths, potentially promoting unfavourable intraventricular flow patterns which are thought to be correlated to the risk of thrombosis. This study aimed to present a 3D multiscale computational fluid dynamic model of the left ventricle (LV) developed using a commercial software, Ansys, and evaluate the risk of thrombosis with varying inflow cannula insertion lengths in a severely dilated LV. Based on a HeartWare HVAD inflow cannula, insertion lengths of 5, 19, 24 and 50 mm represented cases of apical hypertrophy, typical ranges of apical thicknesses and an experimental length, respectively. The risk of thrombosis was evaluated based on blood washout, residence time, instantaneous blood stagnation and a pulsatility index. By introducing fresh blood to displace pre-existing blood in the LV, after 5 cardiac cycles, 46.7%, 45.7%, 45.1% and 41.8% of pre-existing blood remained for insertion lengths of 5, 19, 24 and 50 mm, respectively. Compared to the 50 mm insertion, blood residence time was at least 9%, 7% and 6% higher with the 5, 19 and 24 mm insertion lengths, respectively. No instantaneous stagnation at the apex was observed directly after the E-wave. Pulsatility indices adjacent to the cannula increased with shorter insertion lengths. For the specific scenario studied, a longer insertion length, relative to LV size, may be advantageous to minimise thrombosis by increasing LV washout and reducing blood residence time.
Publisher: Springer Science and Business Media LLC
Date: 12-2016
Publisher: Wiley
Date: 27-09-2018
DOI: 10.1111/AOR.13330
Abstract: Rotary left ventricular assist devices (LVADs) are commonly operated at a constant speed, attenuating blood flow pulsatility. Speed modulation of rotary LVADs has been demonstrated to improve vascular pulsatility and pump washout. The effect of LVAD speed modulation on intraventricular flow dynamics is not well understood, which may have an influence on thromboembolic events. This study aimed to numerically evaluate intraventricular flow characteristics with a speed modulated LVAD. A severely dilated anatomical left ventricle was supported by a HeartWare HVAD in a three-dimensional multiscale computational fluid dynamics model. Three LVAD operating scenarios were evaluated: constant speed and sinusoidal co- and counter-pulsation. In all operating scenarios, the mean pump speed was set to restore the cardiac output to 5.0 L/min. Co- and counter-pulsation was speed modulated with an litude of 750 rpm. The risk of thrombosis was evaluated based on blood residence time, ventricular washout, kinetic energy densities, and a pulsatility index map. Blood residence time for co-pulsation was on average 1.8 and 3.7% lower than constant speed and counter-pulsation mode, respectively. After introducing fresh blood to displace preexisting blood for 10 cardiac cycles, co-pulsation had 1.5% less old blood in comparison to counter-pulsation. Apical energy densities were 84 and 27% higher for co-pulsation in comparison to counter-pulsation and constant speed mode, respectively. Co-pulsation had an increased pulsatility index around the left ventricular outflow tract and mid-ventricle. Improved flow dynamics with co-pulsation was caused by increased E-wave velocities which minimized blood stasis. In the studied scenario and from the perspective of intraventricular flow dynamics, co-pulsation of rotary LVADs could minimize the risk of intraventricular thrombosis.
Location: United Kingdom of Great Britain and Northern Ireland
Location: United Kingdom of Great Britain and Northern Ireland
Location: United Kingdom of Great Britain and Northern Ireland