Publisher: Hindawi Limited
Date: 28-12-2012
DOI: 10.1111/ANE.12063
Abstract: Infusion tests are used to diagnose and select patients with idiopathic normal pressure hydrocephalus (INPH) for shunt surgery. The test characterizes cerebrospinal fluid dynamics and estimates parameters of the cerebrospinal fluid system, the pressure-volume index (PVI) and the outflow conductance (Cout). The Oscillating Pressure Infusion (OPI) method was developed to improve the test and reduce the investigation time. The aim of this study was to evaluate the new OPI method by comparing it with an established reference method. Forty-seven patients (age 71.2 ± 8.9 years) with communicating hydrocephalus underwent a preoperative lumbar infusion investigation with two consecutive infusion protocols, reference (42 min) and new (20 min), that is, 94 infusion tests in total. The OPI method estimated Cout and PVI simultaneously. A real-time analysis of reliability was applied to investigate the possibility of infusion time reduction. The difference in Cout between the methods was 1.2 ± 1.8 μl/s/kPa (ΔRout = -0.8 ± 3.5 mmHg/ml/min), P < 0.05, n = 47. With the reliability analysis, the preset 20 min of active infusion could have been even further reduced for 19 patients to between 10 and 19 min. PVI was estimated to 16.1 ± 6.9 ml, n = 47. The novel Oscillating Pressure Infusion method produced real-time estimates of Cout including estimates of reliability that was in good agreement with the reference method and allows for a reduced and in idualized investigation time.
Publisher: IEEE
Date: 08-2007
Publisher: Springer Science and Business Media LLC
Date: 06-08-2010
DOI: 10.1007/S11517-010-0670-6
Abstract: Hydrocephalus is related to a disturbed cerebrospinal fluid (CSF) system. For diagnosis, lumbar infusion test are performed to estimate outflow conductance, C (out), and pressure volume index, PVI, of the CSF system. Infusion patterns and analysis methods used in current clinical practice are not optimized. Minimizing the investigation time with sufficient accuracy is of major clinical relevance. The aim of this study was to propose and experimentally evaluate a new method, the oscillating pressure infusion (OPI). The non-linear model of the CSF system was transformed into a linear time invariant system. Using an oscillating pressure pattern and linear system identification methods, C (out) and PVI with confidence intervals, were estimated in real-time. Forty-two OPI and constant pressure infusion (CPI) investigations were performed on an experimental CSF system, designed with PVI = 25.5 ml and variable C (out). The ARX model robustly estimated C (out) (mean C (out,OPI) - C (out,CPI) = 0.08 μl/(s kPa), n = 42, P = 0.68). The Box-Jenkins model proved most reliable for PVI (23.7 ± 2.0 ml, n = 42). The OPI method, with its oscillating pressure pattern and new parameter estimation methods, efficiently estimated C (out) and PVI as well as their confidence intervals in real-time. The results from this experimental study show potential for the OPI method and supports further evaluation in a clinical setting.
Publisher: IOP Publishing
Date: 05-10-2007
DOI: 10.1088/0967-3334/28/11/003
Abstract: Idiopathic normal pressure hydrocephalus (INPH) patients have a disturbance in the dynamics of the cerebrospinal fluid (CSF) system. The outflow conductance, C, of the CSF system has been suggested to be prognostic for positive outcome after treatment with a CSF shunt. All current methods for estimation of C have drawbacks these include lack of information on the accuracy and relatively long investigation times. Thus, there is a need for improved methods. To accomplish this, the theoretical framework for a new adaptive observer (OBS) was developed which provides real-time estimation of C. The aim of this study was to evaluate the OBS method and to compare it with the constant pressure infusion (CPI) method. The OBS method was applied to data from infusion investigations performed with the CPI method. These consisted of repeated measurements on an experimental set-up and 30 patients with suspected INPH. There was no significant difference in C between the CPI and the OBS method for the experimental set-up. For the patients there was a significant difference, -0.84+/-1.25 microl (s kPa)(-1), mean +/- SD (paired s le t-test, p<0.05). However, such a difference is within clinically acceptable limits. This encourages further development of this new real-time approach for estimation of the outflow conductance.