ORCID Profile
0000-0002-1260-0535
Current Organisations
International Islamic University Malaysia
,
UNSW Sydney
Does something not look right? The information on this page has been harvested from data sources that may not be up to date. We continue to work with information providers to improve coverage and quality. To report an issue, use the Feedback Form.
Publisher: Ovid Technologies (Wolters Kluwer Health)
Date: 02-2017
DOI: 10.1097/OPX.0000000000001012
Abstract: To observe the emission intensity profile of sodium fluorescein in the human tear film as a function of time and concentration. Twenty-two participants with no dry eye signs or symptoms were randomly allocated to receive 1 μL of either a 2 or 10% concentration of fluorescein to one eye. Images of the inferior tear meniscus were captured at regular intervals over 30 minutes and the process repeated for the other eye with the alternate concentration. Fluorescence intensity was quantified on the basis of the grayscale pixel values in the tear meniscus images. The fluorescein-decay profile over time and between concentrations was determined. Peak fluorescence intensity was reached in 3.9 ± 3.0 and 8.7 ± 4.4 minutes after instillation for the 2 and 10% concentrations, respectively. The 10% concentration of fluorescein maintained its peak fluorescence intensity longer than the 2% concentration (about 9 and 2 minutes, respectively). The peak fluorescence intensity was not significantly different between the higher and lower concentrations (44 ± 37 vs. 38 ± 32 units, P = .22). For both concentrations, the observed intensity did not return to baseline levels by the end of the 30-minute observation time. The fluorescence intensity of fluorescein in a clinical setting varies with time such that both the onset and duration of maximum brightness are concentration dependent. At low concentration (2%), maximum brightness occurs almost immediately after instillation and lasts about 2 minutes. With a higher concentration (10%), the effective working window is delayed for about 7 to 8 minutes. Irrespective of initial concentration, observable fluorescence remains in the tear film beyond 30 minutes post-instillation.
Publisher: Ovid Technologies (Wolters Kluwer Health)
Date: 09-2019
DOI: 10.1097/OPX.0000000000001422
Abstract: Prominent ocular surface dryness and poor tear film quality among electronic cigarette (e-cigarette) smokers (or vapers) indicate potential harm to the eyes from vaping. These findings may serve as precautionary signs for e-cigarette users and exposed bystanders. Little is known about the effect of e-cigarettes on the eyes except for reported eye irritation among in iduals who were exposed to e-cigarette vapors and e-liquids. This study aims to investigate the effect of vaping on ocular surface health of long-term vapers. Twenty-one vapers and 21 healthy nonsmokers who are all male underwent measurements of the Ocular Surface Disease Index, noninvasive tear breakup time, fluorescein breakup time, ocular surface staining, tear meniscus height, and the Schirmer test. The effect of voltage used during vaping was also evaluated against the measurements. Vapers experienced moderate-to-severe eye dryness (25.0 [interquartile range, 14.6 to 43.7]) as indicated by the Ocular Surface Disease Index. Significant reductions of noninvasive tear breakup time (3.13 ± 0.97 vs. 6.57 ± 2.31 seconds P .0001), fluorescein breakup time (2.68 [interquartile range, 2.33 to 3.18] vs. 4.12 [3.56 to 5.07] seconds P .0001), and tear meniscus height (203.0 [193.0 to 225.5] vs. 235.0 [210.0 to 253.50] μm P = .002) were noted in vapers, but the Schirmer test showed higher results (14.5 [12.0 to 17.0] vs. 8.0 [7.0 to 11.0] mm P = .001) compared with nonsmokers. Increase in vaping voltage aggravated the dry eye symptoms and tear instability ( P .05). Higher Schirmer test result was also noted as voltage increases. Vapers showed moderate-to-severe symptomatic dry eye and poorer tear film quality compared with nonsmokers. High vaping voltage may have aggravated the dry eye syndrome because of hazardous by-products from pyrolysis of the e-liquid constituents. Investigation of the ocular surface health at cellular and molecular levels is warranted to gain a deeper understanding on the effect of e-cigarette to the eyes.
Publisher: Wiley
Date: 23-09-2023
DOI: 10.1111/HEAD.14630
Location: No location found
No related grants have been discovered for nur amalina md isa.