ORCID Profile
0000-0001-6050-0195
Current Organisation
Universiti Malaya
Does something not look right? The information on this page has been harvested from data sources that may not be up to date. We continue to work with information providers to improve coverage and quality. To report an issue, use the Feedback Form.
Publisher: Elsevier BV
Date: 04-2015
Publisher: Springer Science and Business Media LLC
Date: 27-02-2013
DOI: 10.1007/S00216-013-6782-8
Abstract: A displacement immunoassay involves having a labelled analogue of the analyte (the epitope) already bound to the antibody. The presence of the analyte causes a competition for antibodies, and some of the antibodies dissociates from the epitope so that it can bind with the analyte. Herein, the influence of the affinity of the surface-bound epitope for the antibody on the sensitivity and selectivity of a displacement immunosensor is explored both theoretically and experimentally. An electrochemical immunosensor described previously, where the dissociation of antibodies from an electrode surface causes an increase in current from surface-bound ferrocene species, is used for this purpose. As expected, the ease and effectiveness of the bound antibody being displaced is inversely related to the affinity of the antibody to the surface-bound epitope relative to the analyte in solution as expected. However, if the affinity constant is too low, selectivity and/or sensitivity are compromised. Experimental results are qualitatively compared with a simple mass-action model.
Publisher: Elsevier BV
Date: 08-2017
Publisher: Elsevier BV
Date: 02-2018
Publisher: Wiley
Date: 26-12-2022
Abstract: Increasing public awareness of food quality and safety has prompted a rapid increase in food authentication of halal food, which covers the production method, technical processing, identification of undeclared components, and species substitution in halal food products. This urges for extensive research into analytical methods to obtain accurate and reliable results for monitoring and controlling the authenticity of halal food. Nonetheless, authentication of halal food is often challenging because of the complex nature of food and the increasing number of food adulterants that cause detection difficulties. This review provides a comprehensive and impartial overview of recent studies on the analytical techniques used in the analysis of halal food authenticity (from 1980 to the present, but there has been no significant trend in the choice of techniques for authentication of halal food during this period). Additionally, this review highlights the classification of different methodologies based on validity measures that provide valuable information for future developments in advanced technology. In addition, methodological developments, and novel emerging techniques as well as their implementations have been explored in the evaluation of halal food authentication. This includes food categories that require halal authentication, illustrating the advantages and disadvantages as well as shortcomings during the use of all approaches in the halal food industry.
Publisher: Springer Science and Business Media LLC
Date: 29-05-2023
Publisher: IEEE
Date: 2003
Publisher: Elsevier BV
Date: 10-2020
Publisher: Elsevier BV
Date: 03-2016
Publisher: The Electrochemical Society
Date: 19-12-2016
DOI: 10.1149/2.0471603JES
Publisher: Elsevier BV
Date: 2015
DOI: 10.1016/J.CCA.2014.10.019
Abstract: Type 2 diabetes mellitus (T2DM) is a pressing health issue that threatens global health and the productivity of populations worldwide. Despite its long-recognized role in diabetes management, glycated hemoglobin (HbA1c) only received WHO endorsement as a T2DM diagnostic tool in 2011. Although conventional plasma-specific tests have long been utilized to diagnose T2DM, the public should be informed that plasma-specific tests are not markedly better than HbA1c tests, particularly in terms of variability and convenience for diagnosing diabetes. In the midst of the debates associated with establishing HbA1c as the preeminent diabetes diagnostic tool, unceasing efforts to standardize HbA1c tests have played an integral part in achieving more efficient communication from laboratory to clinical practice and thus better diabetes care. This review discusses the current status of HbA1c tests in the diagnosis, prevention, treatment and management of T2DM across the globe, focusing on increasing the recognition of glycated hemoglobin variants with effective utilization of different HbA1c methods, updating the current status of HbA1c standardization programs, tapping into the potential of POC analyzers to establish a cost-effective HbA1c test for diabetes care, and inspiring the advancement of HbA1c biosensors for future clinical usage.
Publisher: Elsevier BV
Date: 02-2016
DOI: 10.1016/J.CHROMA.2015.12.087
Abstract: This paper reports the application of hexamethyldisilazane-trimethylsilyl trifluoromethanesulfonate (HMDS-TMSOTf) for the simultaneous silylation of 3-monochloro-1,2-propanediol (3-MCPD) and 1,3-dicholoropropanol (1,3-DCP) in solid and liquid food s les. 3-MCPD and 1,3-DCP are chloropropanols that have been established as Group 2B carcinogens in clinical testing. They can be found in heat-processed food, especially when an extended high-temperature treatment is required. However, the current AOAC detection method is time-consuming and expensive. Thus, HMDS-TMSOTf was used in this study to provide a safer, and cost-effective alternative to the HFBI method. Three important steps are involved in the quantification of 3-MCPD and 1,3-DCP: extraction, derivatization and quantification. The optimization of the derivatization process, which involved focusing on the catalyst volume, derivatization temperature, and derivatization time was performed based on the findings obtained from both the Box-Behnken modeling and a real experimental set up. With the optimized conditions, the newly developed method was used for actual food s le quantification and the results were compared with those obtained via the standard AOAC method. The developed method required less s les and reagents but it could be used to achieve lower limits of quantification (0.0043mgL(-1) for 1,3-DCP and 0.0011mgL(-1) for 3-MCPD) and detection (0.0028mgL(-1) for 1,3-DCP and 0.0008mgL(-1) for 3-MCPD). All the detected concentrations are below the maximum tolerable limit of 0.02mgL(-1). The percentage of recovery obtained from food s le analysis was between 83% and 96%. The new procedure was validated with the AOAC method and showed a comparable performance. The HMDS-TMSOTf derivatization strategy is capable of simultaneously derivatizing 1,3-DCP and 3-MCPD at room temperature, and it also serves as a rapid, sensitive, and accurate analytical method for food s les analysis.
Publisher: Springer Science and Business Media LLC
Date: 18-05-2023
Publisher: Springer International Publishing
Date: 2022
Publisher: Wiley
Date: 12-12-2015
Publisher: Elsevier BV
Date: 06-2023
Publisher: Elsevier BV
Date: 03-2016
DOI: 10.1016/J.JCHROMB.2016.01.059
Abstract: An immunosensor that operates based on the principles of lateral flow was developed for direct detection of hemoglobin A1c (HbA1c) in whole blood. We utilized colloidal gold-functionalized antibodies to transduce the specific signal generated when sandwich immuno-complexes were formed on the strip in the presence of HbA1c. The number and intensity of the test lines on the strips indicate normal, under control, and elevated levels of HbA1c. In addition, a linear relationship between HbA1c levels and immunosensor signal intensity was confirmed, with a dynamic range of 4-14% (20-130 mmol mol(-1)) HbA1c. Using this linear relationship, we determined the HbA1c levels in blood as a function of the signal intensity on the strips. Measurements were validated using the Bio-Rad Variant II HPLC and DCA Vantage tests. Moreover, the immunosensor was verified to be highly selective for detection of HbA1c against HbA0, glycated species of HbA0, and HbA2. The limit of detection was found to be 42.5 μg mL(-1) (1.35 mmol mol(-1)) HbA1c, which is reasonably sensitive compared to the values reported for microarray immunoassays. The shelf life of the immunosensor was estimated to be 1.4 months when stored at ambient temperature, indicating that the immunoassay is stable. Thus, the lateral flow immunosensor developed here was shown to be capable of performing selective, accurate, rapid, and stable detection of HbA1c in human blood s les.
Publisher: Elsevier BV
Date: 05-2022
DOI: 10.1016/J.TALANTA.2022.123271
Abstract: Oil and grease content in wastewater is used as an environmental monitoring parameter in the oil and gas industry to prevent serious pollution. Conventional oil and grease laboratory testing is time-consuming and necessitates the use of a hazardous chemical solvent, resulting in non-real-time test data and unnecessary chemical waste. On-site or real-time analysis can enable monitoring of oil and grease in wastewater before discharge to the environment from an operating plant, allowing immediate action to be taken to mitigate environmental impact before contamination spirals out of control. Bioluminescent whole-cell biosensors have been reported to have high sensitivity and selectivity in environmental s les, but only for a few traces of organic compounds such as polycyclic aromatics and naphthalene, allowing for faster analysis times. However, no evaluation of biosensor application for oil and grease (a mixture of hydrocarbons) detection in wastewater, which is critical in the oil and gas industry, has been published to date. Herein, the advantages, disadvantages, challenges, and limitations of using a whole-cell bioluminescent biosensor technology to measure oil and grease content in wastewater are carefully reviewed. This review attempts to bridge the knowledge gap between conventional laboratory methods and biosensor technology in terms of analytical challenges, identifying areas for improvement as well as real-world applications for oil and grease content detection in wastewater.
Publisher: Springer Nature Singapore
Date: 2022
Publisher: Springer Science and Business Media LLC
Date: 20-11-2019
DOI: 10.1007/S11356-019-06718-2
Abstract: Human health is threatened by significant emissions of heavy metals into the urban environment due to various activities. Various studies describing health risk analyses on soil and dust have been conducted previously. However, there are limited studies that have been carried out regarding the potential health risk assessment of heavy metals in urban road dust of < 63-μm diameter, via incidental ingestion, dermal contact, and inhalation exposure routes by children and adults in developing countries. Therefore, this study evaluated the health risks of heavy metal exposure via ingestion, dermal contact, and inhalation of urban dust particles in Petaling Jaya, Malaysia. Heavy metals such as lead (Pb), chromium (Cr), zinc (Zn), copper (Cu), and manganese (Mn) were measured using dust s les obtained from industrial, high-traffic, commercial, and residential areas by using inductively coupled plasma mass spectrometry (ICP-MS). The principal component and hierarchical cluster analysis showed the dominance of these metal concentrations at sites associated with anthropogenic activities. This was suggestive of industrial, traffic emissions, atmospheric depositions, and wind as the significant contributors towards urban dust contamination in the study sites. Further exploratory analysis underlined Cr, Pb, Cu, and Zn as the most representative metals in the dust s les. In accommodating the uncertainties associated with health risk calculations and simulating the reasonable maximum exposure of these metals, the related health risks were estimated at the 75th and 95th percentiles. Furthermore, assessing the exposure to carcinogenic and non-carcinogenic metals in the dust revealed that ingestion was the primary route of consumption. Children who ingested dust particles in Petaling Jaya could be more vulnerable to carcinogenic and non-carcinogenic risks, but the exposure for both children and adults showed no potential health effects. Therefore, this study serves as an important premise for a review and reformation of the existing environmental quality standards for human health safety.
Publisher: Elsevier BV
Date: 08-2017
Publisher: Elsevier
Date: 2022
Publisher: Elsevier BV
Date: 2015
Publisher: Royal Society of Chemistry (RSC)
Date: 2015
DOI: 10.1039/C5AY00518C
Abstract: We developed an immunosensor that operates based on the lateral flow principle designed to detect haemoglobin A1c (HbA1c), a biomarker for type 2 diabetes mellitus in human blood s les.
Publisher: Springer Nature Singapore
Date: 2022
Publisher: Elsevier BV
Date: 05-2019
Publisher: Informa UK Limited
Date: 15-10-2019
Publisher: Springer International Publishing
Date: 2022
Publisher: Elsevier BV
Date: 2011
DOI: 10.1016/J.BIOS.2010.08.082
Abstract: An immuno-biosensing interface comprising a mixed layer of an oligo(ethylene glycol) (OEG) component, and an oligo(phenylethynylene) molecular wire (MW) is described. The OEG controls the interaction of proteins and electroactive interferences with the surface and the MW allows electrochemical communication to the underlying glassy carbon electrode. The layers are formed from in situ generated-aryl diazonium cations. To the distal end of the MW, a redox probe 1,1'-di(aminomethyl)ferrocene is attached followed by the surface bound epitope (the structural feature the antibody selectively recognizes) to which an antibody would bind. Association or disassociation of the antibody with the sensing interface causes a modulation of the ferrocene electrochemistry. X-ray photoelectron spectroscopy, cyclic voltammetry, and square wave voltammetry have been used to characterize the step-wise fabrication of the sensing interface. The influence of the molar ratio of the MW and OEG deposited onto the sensor interface was explored relative to the final sensor sensitivity. Five combinations of MW/OEG 1:0, 1:20, 1:50, 1:75 and 1:100 were tested on sensor sensitivity detection for a model analyte (biotin) free in solution, via a displacement assay. The ratio of 1:50 was found to give the highest sensitivity. At this ratio, good reproducibility (RSD 6.8%) and repeatability (RSD 9.6%) was achieved. This immuno-biosensor provides an intervention free immuno-biosensing platform for agriculture and biomedical s les.
Publisher: Elsevier BV
Date: 12-2017
DOI: 10.1016/J.FOODCHEM.2017.06.029
Abstract: Butylated hydroxyanisole (BHA), butylated hydroxytoluene (BHT), and tert-butylhydroquinone (TBHQ) are synthetic antioxidants used in the food industry. Herein, we describe the development of a novel graphite nanocomposite-based electrochemical sensor for the multiplex detection and measurement of BHA, BHT, and TBHQ levels in complex food s les using a linear sweep voltammetry technique. Moreover, our newly established analytical method exhibited good sensitivity, limit of detection, limit of quantitation, and selectivity. The accuracy and reliability of analytical results were challenged by method validation and comparison with the results of the liquid chromatography method, where a linear correlation of more than 0.99 was achieved. The addition of sodium dodecyl sulfate as supporting additive further enhanced the LSV response (anodic peak current, I
Publisher: Royal Society of Chemistry (RSC)
Date: 2023
DOI: 10.1039/D3AY00647F
Abstract: Unpredictable natural disasters, disease outbreaks, climate change, pollution, and war constantly threaten food crop production.
Publisher: Elsevier BV
Date: 11-2023
Publisher: American Chemical Society (ACS)
Date: 03-11-2021
Publisher: Elsevier BV
Date: 08-2017
DOI: 10.1016/J.JCHROMB.2017.06.040
Abstract: Clinicians, working in the health-care diagnostic systems of developing countries, currently face the challenges of rising costs, increased number of patient visits, and limited resources. A significant trend is using low-cost substrates to develop microfluidic devices for diagnostic purposes. Various fabrication techniques, materials, and detection methods have been explored to develop these devices. Microfluidic paper-based analytical devices (μPADs) have gained attention for sensing multiplex analytes, confirming diagnostic test results, rapid s le analysis, and reducing the volume of s les and analytical reagents. μPADs, which can provide accurate and reliable direct measurement without s le pretreatment, can reduce patient medical burden and yield rapid test results, aiding physicians in choosing appropriate treatment. The objectives of this review are to provide an overview of the strategies used for developing paper-based sensors with enhanced analytical performances and to discuss the current challenges, limitations, advantages, disadvantages, and future prospects of paper-based microfluidic platforms in clinical diagnostics. μPADs, with validated and justified analytical performances, can potentially improve the quality of life by providing inexpensive, rapid, portable, biodegradable, and reliable diagnostics.
Publisher: Royal Society of Chemistry (RSC)
Date: 2012
DOI: 10.1039/C2AN16034J
Abstract: An electrochemical immuno-biosensor for detecting glycosylated haemoglobin (HbA1c) is reported based on glassy carbon (GC) electrodes with a mixed layer of an oligo(phenylethynylene) molecular wire (MW) and an oligo(ethylene glycol) (OEG). The mixed layer is formed from in situ-generated aryl diazonium cations. To the distal end of the MW, a redox probe 1,1'-di(aminomethyl)ferrocene (FDMA) was attached followed by the covalent attachment of an epitope N-glycosylated pentapeptide (GPP), an analogon to HbA1c, to which an anti-HbA1c monocolonal antibody IgG can selectively bind. HbA1c was detected by a competitive inhibition assay based on the competition for binding to anti-HbA1c IgG antibodies between the analyte in solution, HbA1c, and the surface bound epitope GPP. Exposure of the GPP modified sensing interface to the mixture of anti-HbA1c IgG antibody and HbA1c results in the attenuation of ferrocene electrochemistry due to free antibody binding to the interface. Higher concentrations of analyte led to higher Faradaic currents as less anti-HbA1c IgG is available to bind to the electrode surface. It was observed that there is a good linear relationship between the relative Faradaic current of FDMA and the concentration of HbA1c from 4.5% to 15.1% of total haemoglobin in serum without the need for washing or rinsing steps.
Publisher: Springer International Publishing
Date: 2022
Publisher: Elsevier BV
Date: 08-2021
Publisher: Springer International Publishing
Date: 2022
Publisher: Wiley
Date: 07-06-2011
Publisher: Springer Science and Business Media LLC
Date: 10-2015
Abstract: Graphite material is abundantly available from recyclable sources. It possesses a good electrical conductance property, which makes it an attractive material as a working electrode. However, due to a high activation overpotential it has limited applications as compared to other solid metal electrodes. In this present work, we obtained a graphite rod from a used battery, and carried out electrochemical improvements by electro-deposition with gold nanoparticles (AuNPs). The heterogeneous electron transfer rate and electron transfer resistance of the fabricated electrode were improved. The electrode overpotential has shown improvement by 50 mV, and the effective surface area has increased by 2 fold. To determine the practicability of the AuNPs/graphite electrode, we used the electrode in the analysis of myricetin. A square-wave voltammetry was used in the analysis, and the detection response increased by 2.5 fold, which suggested an improvement in the electrode sensitivity.
Publisher: Elsevier BV
Date: 03-2019
DOI: 10.1016/J.BIOS.2018.12.049
Abstract: The early detection of acute myocardial infarction (AMI) upon the onset of chest pain symptoms is crucial for patient survival. However, this detection is challenging, particularly without a persistent elevation of ST-segment reflected in an electrocardiogram or in blood tests. A majority of the available point-of-care testing devices allow accurate and rapid diagnosis of AMI. However, AMI diagnosis is reliable only at intermediate and later stages, with myocardial injury (> 6 h) and MI, based on the expression of specific cardiac biomarkers including troponin I or T (cTnI or cTnT), creatine kinase-MB (CK-MB), and myoglobin. Diagnosis at the early myocardial ischemia stage is not possible. To overcome this limitation, a sensitive and rapid microfluidic paper-based device (µPAD) was developed for the simultaneous detection of multiple cardiac biomarkers for the early and late diagnosis of AMI. The glycogen phosphorylase isoenzyme BB (GPBB) was detected during early (within first 4 h) ischemic myocardial injury. On the same µPAD platform, detection of prolonged elevation of levels of cTnT and CK-MB, which are only produced 6 h after the onset of chest pain in human serum, was possible. Sandwich immunoassay performed on the µPAD achieved reproducibility (RSD approximately 10% and intra-and inter-day precision (CV 10-20%, 99th percentile), as well as consistently stable test results for 28 days, with strong correlation (r
Publisher: Elsevier BV
Date: 03-2019
Publisher: Springer International Publishing
Date: 2022
Publisher: Springer Science and Business Media LLC
Date: 27-11-2022
DOI: 10.1007/S00216-021-03758-X
Abstract: A sensitive biosensor capable of detecting trace concentrations of several cancer biomarkers in clinical s les is critical for early detection of cancer because different cancer biomarkers may be expressed at different stages of cancer. Previous multiplex studies using microarrays or color-coded beads had limited multiplex detection in a single well, and difficulty in optimizing and unifying the incubation parameters for all tests made in different wells had posed challenges to small s le size and lengthened assay time. Herein, we proposed a novel approach to achieve multiplex analysis on a single three-dimensional porous calcium alginate bead. Because of the high surface area to volume ratio of the calcium alginate immuno-bead, the sensitivity and linear dynamic range of the as-proposed multiplex analysis method are significantly improved. Based on the direct sandwich immunoassay principle, dual-capturing antibodies were encapsulated into a single 3D porous calcium alginate bead as a proof-of-concept for multiplexity detection of serum-HER2 and serum-CA125 breast cancer biomarkers. High sensitivity was attained, with LODs of 0.004 ng mL
Publisher: MDPI AG
Date: 20-09-2021
DOI: 10.3390/MOLECULES26185696
Abstract: Protein-protein interaction plays an essential role in almost all cellular processes and biological functions. Coupling molecular dynamics (MD) simulations and nanoparticle tracking analysis (NTA) assay offered a simple, rapid, and direct approach in monitoring the protein-protein binding process and predicting the binding affinity. Our case study of designed ankyrin repeats proteins (DARPins)—AnkGAG1D4 and the single point mutated AnkGAG1D4-Y56A for HIV-1 capsid protein (CA) were investigated. As reported, AnkGAG1D4 bound with CA for inhibitory activity however, it lost its inhibitory strength when tyrosine at residue 56 AnkGAG1D4, the most key residue was replaced by alanine (AnkGAG1D4-Y56A). Through NTA, the binding of DARPins and CA was measured by monitoring the increment of the hydrodynamic radius of the AnkGAG1D4-gold conjugated nanoparticles (AnkGAG1D4-GNP) and AnkGAG1D4-Y56A-GNP upon interaction with CA in buffer solution. The size of the AnkGAG1D4-GNP increased when it interacted with CA but not AnkGAG1D4-Y56A-GNP. In addition, a much higher binding free energy (∆GB) of AnkGAG1D4-Y56A (−31 kcal/mol) obtained from MD further suggested affinity for CA completely reduced compared to AnkGAG1D4 (−60 kcal/mol). The possible mechanism of the protein-protein binding was explored in detail by decomposing the binding free energy for crucial residues identification and hydrogen bond analysis.
Publisher: IEEE
Date: 02-2010
Publisher: Wiley
Date: 20-04-2010
Publisher: American Chemical Society (ACS)
Date: 08-09-2017
DOI: 10.1021/ACS.ANALCHEM.7B02432
Abstract: Guanine (G), adenine (A), thymine (T), and cytosine (C) are the four basic constituents of DNA. Studies on DNA composition have focused especially on DNA damage and genotoxicity. However, the development of a rapid, simple, and multiplex method for the simultaneous measurement of the four DNA bases remains a challenge. In this study, we describe a graphite-based nanocomposite electrode (Au-rGO/MWCNT/graphite) that uses a simple electro-co-deposition approach. We successfully applied the developed sensor for multiplex detection of G, A, T, and C, using square-wave voltammetry. The sensor was tested using real animal and plant DNA s les in which the hydrolysis of T and C could be achieved with 8 mol L
Publisher: Elsevier BV
Date: 07-2022
DOI: 10.1016/J.ACA.2022.339989
Abstract: Since the invention of fully synthetic plastic in the 1900s, plastics have been extensively applied in various fields and represent a significant market due to their satisfactory properties. However, the non-biodegradable nature of most plastics has contributed to the accumulation of plastic waste, which poses a threat to both the environment and living beings. Given this, biodegradable polymers have emerged as eco-friendly substitutes for non-biodegradable polymers, and standard test methods have been established to evaluate polymer biodegradability. Technological advancement and the weaknesses of conventional test methods drive the invention of sensors that enable real-time monitoring of biodegradability. Besides, biodegradable polymers have been utilized to make sensors with different functionalities. Given this, the current paper is the first to compare and contrast sensors capable of identifying biodegradable polymers. The detection using sensors represents an innovative perspective for real-time monitoring of biodegradability. Besides, sensors made from biodegradable polymers are included, and these sensors are of different types and show various applications. Finally, the challenges associated with developing these sensors are described to advance future research.
Publisher: Elsevier BV
Date: 05-2020
DOI: 10.1016/J.FOODCHEM.2019.126033
Abstract: Quantifiable levels of 3-chloropropane-1,2-diol (3-MCPD) and 1,3-dichloro-2-propanol (1,3-DCP) were found in domestically manufactured soy-based sauces. Selected commercial foods in the Malaysian market (n = 43) were analyzed for their 3-MCPD and 1,3-DCP contents using a validated gas chromatography-mass spectrometry technique. The 3-MCPD and 1,3-DCP contents of the analyzed food s les varied from not detectable levels to 0.1223 ± 0.0419 mg kg
Publisher: MDPI AG
Date: 10-01-2022
DOI: 10.3390/NANO12020221
Abstract: Recently, several studies have been conducted on wearable biosensors. Despite being skin-adhesive and mountable diagnostic devices, flexible biosensor patches cannot truly be considered wearable biosensors if they need to be connected to external instruments rocessors to provide meaningful data/readings. A realistic and usable wearable biosensor should be self-contained, with a fully integrated device framework carefully designed and configured to provide reliable and intelligent diagnostics. There are several major challenges to achieving continuous sweat monitoring in real time for the systematic and effective management of type II diabetes (e.g., prevention, screening, monitoring, and treatment) through wearable sweat glucose biosensors. Consequently, further in-depth research regarding the exact interrelationship between active or passive sweat glucose and blood glucose is required to assess the applicability of wearable glucose biosensors in functional health monitoring. This review provides some useful insights that can enable effective critical studies of these unresolved issues. In this review, we first classify wearable glucose biosensors based on their signal transduction, their respective challenges, and the advanced strategies required to overcome them. Subsequently, the challenges and limitations of enzymatic and non-enzymatic wearable glucose biosensors are discussed and compared. Ten basic criteria to be considered and fulfilled in the development of a suitable, workable, and wearable sweat-based glucose biosensor are listed, based on scientific reports from the last five years. We conclude with our outlook for the controllable, well-defined, and non-invasive monitoring of epidermal glucose for maximum diagnostic potential in the effective management of type II diabetes.
Publisher: Springer International Publishing
Date: 2022
Publisher: Elsevier BV
Date: 02-2018
DOI: 10.1016/J.JPBA.2017.11.064
Abstract: The sharp increase in incidence of dengue infection has necessitated the development of methods for the rapid diagnosis of this deadly disease. Here we report the design and development of a reliable, sensitive, and specific optical immunosensor for the detection of the dengue nonstructural protein 1 (NS1) biomarker in clinical s les obtained during early stages of infection. The present optical NS1 immunosensor comprises a biosensing surface consisting of specific monoclonal NS1 antibody for immunofluorescence-based NS1 antigen determination using fluorescein isothiocyanate (FITC) conjugated to IgG antibody. The linear range of the optical immunosensor was from 15-500ngmL
Publisher: Elsevier BV
Date: 09-2021
Publisher: Royal Society of Chemistry (RSC)
Date: 2019
DOI: 10.1039/C9AY01102A
Abstract: Displacement of an antibody enhanced by negative electro-pulsion.
Publisher: Elsevier BV
Date: 04-2016
DOI: 10.1016/J.BIOS.2015.11.045
Abstract: We describe a gold nanoparticle-based sandwich immunoassay for the dual detection and measurement of hemoglobin A1c (HbA1c) and total hemoglobin in the whole blood (without pretreatment) in a single step for personalized medicine. The optimized antibody-functionalized gold nanoparticles immunoreact simultaneously with HbA1c and total hemoglobin to form a sandwich at distinctive test lines to transduce visible signals. The applicability of this method as a personal management tool was demonstrated by establishing a calibration curve to relate % HbA1c, a useful value for type 2 diabetes management, to the signal ratio of captured HbA1c to all other forms of hemoglobin. The platform showed excellent selectivity (100%) toward HbA1c at distinctive test lines when challenged with HbA0, glycated HbA0 and HbA2. The reproducibility of the measurement was good (6.02%) owing to the dual measurement of HbA1c and total hemoglobin. A blood s le stability test revealed that the quantitative measurement of % HbA1c was consistent and no false-positive results were detected. Also, this method distinguished the blood s le with elevated HbF from the normal s les and the variants. The findings of this study highlight the potential of a lateral flow immunosensor as a simple, inexpensive, consistent, and convenient strategy for the dual measurement of HbA1c and total Hb to provide useful % HbA1c values for better on-site diabetes care.
Publisher: Elsevier BV
Date: 09-2022
DOI: 10.1016/J.TOXICON.2022.07.010
Abstract: Cobra (Naja spp.) envenoming is a life-threatening medical emergency, and a correct diagnosis is crucial to initiating timely and appropriate antivenom treatment. However, snakebite diagnostics remain unavailable in Southeast Asia. This study, therefore, developed an immunodetection assay with a potential diagnostic application for cobra envenoming. The cytotoxin of Naja kaouthia (Thai Monocled Cobra) (Nk-CTX) was purified from its venom to produce CTX-specific antibodies in rabbits and chickens. A double-antibody sandwich enzyme-linked immunosorbent assay was developed using the purified anti-Nk-CTX antibodies (immunoglobulin G and immunoglobulin Y), and its selectivity, specificity, and sensitivity for the venoms of five major cobra species in Southeast Asia (N. kaouthia, Naja sumatrana, Naja sputatrix, Naja siamensis, and Naja philippinensis) were studied. The results showed the immunoassay discriminates cobra venoms from other species commonly implicated in snakebites in Southeast Asia, i.e., the Malayan Krait, Many-banded Krait, King Cobra, Eastern Russell's Viper, Malayan Pit Viper and White-lipped Pit Viper. The immunoassay has a high sensitivity for the five cobra venoms, with detection limits (LoD) ranging from 0.6 to 2.6 ng/ml. Together, the findings suggest the potential diagnostic application of the cytotoxin immunoassay for cobra envenoming. The immunoassay was found to exhibit high immunoreactivity toward ten Asiatic cobra venoms (absorbance > 1.5), in contrast to African cobra venoms with low immunoreactivity (absorbance < 0.9). Considering the varying CTX antigenicity between Asiatic and African cobras, the immunoassay for African cobras should utilize antibodies produced specifically from the cytotoxins of African cobra venoms.
Publisher: Elsevier BV
Date: 2020
DOI: 10.1016/J.BIOS.2019.111792
Abstract: Recently, surface enhanced Raman scattering (SERS) has attracted much attention in medical diagnosis applications owing to better detection sensitivity and lower limit of detection (LOD) than colorimetric detection. In this paper, a novel calibration-free SERS-based μPAD with multi-reaction zones for simultaneous quantitative detection of multiple cardiac biomarkers - GPBB, CK-MB and cTnT for early diagnosis and prognosis of acute myocardial infarction (AMI) are presented. Three distinct Raman probes were synthesised, subsequently conjugated with respective detecting antibodies and used as SERS nanotags for cardiac biomarker detection. Using a conventional calibration curve, quantitative simultaneous measurement of multiple cardiac biomarkers on SERS-based μPAD was performed based on the characteristic Raman spectral features of each reporter used in different nanotags. However, a calibration free point-of-care testing device is required for fast screening to rule-in and rule-out AMI patients. Partial least squares predictive models were developed and incorporated into the immunosensing system, to accurately quantify the three unknown cardiac biomarkers levels in serum based on the previously obtained Raman spectral data. This method allows absolute quantitative measurement when conventional calibration curve fails to provide accurate estimation of cardiac biomarkers, especially at low and high concentration ranges. Under an optimised condition, the LOD of our SERS-based μPAD was identified at 8, 10, and 1 pg mL
Publisher: Informa UK Limited
Date: 18-08-2020
No related grants have been discovered for Dr. Sook Mei Khor.