Publisher: Institute of Electrical and Electronics Engineers (IEEE)
Date: 10-2010
Publisher: Science Alert
Date: 15-09-2009
Publisher: Institute of Advanced Engineering and Science
Date: 06-2017
DOI: 10.11591/IJEECS.V6.I3.PP528-536
Abstract: FACTS devices like the Static synchronous Compensator (STATCOM), are mostly used to enhance the maximum power transfer capability of the transmission Line (TL) system. A Matlab simulation model of Distance Relay protection of TL, with connected STATCOM at the mid-point for optimum power transfer is presented. The STATCOM’s impact on the operation of the relay is assessed with the effects on the relay misoperation in the third zone of protection coverage, during fault conditions, in four different locations.The wrong measured fault impedance by relay resulted to misoperation in zone 3 (under reach phenomena). The simulation result indicates a slight increase in the measured impedance of 1.33 Ω over the actually expected impedance setting (72.02 Ω) of the relay at 220 km protection coverage of zone 3 along the TL. This variation is about 4 km distance outside the expected distance protection coverage for fault in zone 3 as proven.
Publisher: IEEE
Date: 12-2015
Publisher: IEEE
Date: 2009
Publisher: MDPI AG
Date: 04-12-2019
DOI: 10.3390/SU11246908
Abstract: This paper proposes a new population-based hybrid particle swarm optimized-gravitational search algorithm (PSO-GSA) for tuning the parameters of the proportional-integral-derivative (PID) controller of a two-area interconnected dynamic power system with the presence of nonlinearities such as generator rate constraints (GRC) and governor dead-band (GDB). The tuning of controller parameters such as Kp, Ki, and Kd are obtained by minimizing the objective function formulated using the steady-state performance indices like Integral absolute error (IAE) of tie-line power and frequency deviation of interconnected system. To test the robustness of the propounded controller, the system is studied with system uncertainties, such as change in load demand, synchronizing power coefficient and inertia constant. The two-area interconnected power system (TAIPS) is modeled and simulated using Matlab/Simulink. The results exhibit that the steady-state and transient performance indices such as IAE, settling time, and control effort are impressively enhanced by an amount of 87.65%, 15.39%, and 91.17% in area-1 and 86.46%, 41.35%, and 91.04% in area-2, respectively, by the proposed method compared to other techniques presented. The minimum control effort of PSO-GSA-tuned PID controller depicts the robust performance of the controller compared to other non-meta-heuristic and meta-heuristic methods presented. The proffered method is also validated using the hardware-in-the-loop (HIL) real-time digital simulation to study the effectiveness of the controller.
Publisher: UK Simulation Society
Date: 15-01-2019
Publisher: Institute of Electrical and Electronics Engineers (IEEE)
Date: 2021
Publisher: Elsevier BV
Date: 10-2011
Publisher: Institute of Electrical and Electronics Engineers (IEEE)
Date: 2022
Publisher: SAGE Publications
Date: 19-05-2014
Abstract: In the motivation of tapping the strong potential of computational intelligence in discovering knowledge of protective relay operations using data mining, modeling and simulation of an actual industrial numerical distance relay and its recording facility are a vital requisite. This is justified by the practicality and necessity of ulging the decision algorithm hidden in the recorded relay event report using computational intelligence-based data mining. Thus, this paper studies the detailed modeling and simulation of an industrial AREVA MiCOM P441 distance relay, accommodated together with its own simulated event report recording facility. The idea is to provide the flexibility of allowing the simulated event report to have sufficiently significant depth and breadth for data mining purposes. The modeled relay has operated correctly and discriminatively in deciding circuit breaker pole(s) to be tripped in stipulated assertion times as per the Malaysian licensee’s requirements for various faults and protected zones along a transmission line. It has subsequently been validated successfully by the performance of the real field AREVA MiCOM P441 distance relay belonging to the Malaysian licensee. With the successful modeling and simulation of the AREVA MiCOM P441 distance relay and its recording facility, such subsequent works as data extraction and preparation, computational intelligence-based data mining for relay decision algorithm discovery and finally a relay analysis expert system development can certainly be executed. These subsequent applications are briefly explored as a demonstration of the benefit offered after the successful modeling of the relay.
Publisher: MDPI AG
Date: 03-01-2020
DOI: 10.3390/EN13010243
Abstract: This paper presents the methodology to detect and identify the type of fault that occurs in the shunt compensated static synchronous compensator (STATCOM) transmission line using a combination of Discrete Wavelet Transform (DWT) and Naive Bayes (NB) classifiers. To study this, the network model is designed using Matlab/Simulink. Different types of faults, such as Line to Ground (LG), Line to Line (LL), Double Line to Ground (LLG) and the three-phase (LLLG) fault, are applied at disparate zones of the system, with and without STATCOM, considering the effect of varying fault resistance. The three-phase fault current waveforms obtained are decomposed into several levels using Daubechies (db) mother wavelet of db4 to extract the features, such as the standard deviation (SD) and energy values. Then, the extracted features are used to train the classifiers, such as Multi-Layer Perceptron Neural Network (MLP), Bayes and the Naive Bayes (NB) classifier to classify the type of fault that occurs in the system. The results obtained reveal that the proposed NB classifier outperforms in terms of accuracy rate, misclassification rate, kappa statistics, mean absolute error (MAE), root mean square error (RMSE), percentage relative absolute error (% RAE) and percentage root relative square error (% RRSE) than both MLP and the Bayes classifier.
Publisher: Universitas Ahmad Dahlan
Date: 08-2018
Publisher: MDPI AG
Date: 10-08-2021
DOI: 10.3390/EN14164877
Abstract: Islanding detection needs are becoming a pivotal constituent of the power system, since the penetration of distributed generators in the utility power system is continually increasing. Accurate threshold setting is an integral part of the island detection scheme since an inappropriate threshold might cause a hazardous situation. This study looked at the islanding conditions as well as two transient faults, such as a single line to ground fault and a three-phase balance fault, to assess the event distinguishing ability of the proposed method. Therefore, the goal of this research was to determine the threshold of the island if the distributed generator (DG) capacity is greater than the connected feeder load, which is the over-frequency island condition, and if the DG capacity is less than the connected feeder load, which is the under-frequency island condition. The significance of this research work is to propose a new island detection threshold setting method using the slip angle and acceleration angle that comes from phasor measurement unit (PMU) voltage angle data. The proposed threshold setting method was simulated in the PowerWorld simulator on a modified IEEE 30 bus system equipped with DG. There are three different interconnection scenarios in the test system and the performance of the proposed method shows that getting the island threshold for all the scenarios requires a single time step or 20 mile seconds after incepting an island into the network. In addition, it can distinguish between the real islanding threshold and the transient faults threshold.
Publisher: American Scientific Publishers
Date: 10-2017
Publisher: Elsevier BV
Date: 08-2012
Publisher: MDPI AG
Date: 13-10-2019
DOI: 10.20944/PREPRINTS201910.0148.V1
Abstract: This paper presents the methodology to detect and identify the type of fault that occurs in shunt connected static synchronous compensator (STATCOM) transmission line using a combination of Discrete Wavelet Transform (DWT) and Naive Bayes classifier. To study this, the network model is designed using Mat-lab/Simulink. The different faults such as Line to Ground (LG), Line to Line (LL), Double Line to Ground (LLG) and three-phase (LLLG) fault are applied at different zones of system with and without STATCOM considering the effect of varying fault resistance. The three-phase fault current waveforms obtained are decomposed into several levels using daubechies mother wavelet of db4 to extract the features such as standard deviation and Energy values. The extracted features are used to train the classifiers such as Multi-Layer Perceptron Neural Network (MLP), Bayes and Naive Bayes (NB) classifier to classify the type of fault that occurs in the system. The results reveal that the proposed NB classifier outperforms in terms of accuracy rate, misclassification rate, kappa statistics, mean absolute error (MAE), root mean square error (RMSE), relative absolute error (RAE) and root-relative square error (RRSE) than MLP and Bayes classifier.
Publisher: MDPI AG
Date: 17-04-2019
DOI: 10.3390/EN12081466
Abstract: This paper presents an investigation on the resonant oscillations of an 11 kV layer-type winding transformer under standard and chopped lightning impulse overvoltage conditions based on calculated parameters. The resistances, inductances and capacitances were calculated in order to develop the transformer winding equivalent circuit. The impulse overvoltages were applied to the high voltage (HV) winding and the resonant oscillations were simulated for each of the layers based on different electrostatic shield placement configurations. It is found that the placement of grounded shields between layer 13 and layer 14 results in the highest resonant oscillation and non-linear initial voltage distribution. The oscillation and linear stress distributions are at the lowest for shield placement between the HV and low voltage (LV) windings.
Publisher: IEEE
Date: 12-2016
Publisher: IEEE
Date: 11-2018
Location: Malaysia
Location: Malaysia