ORCID Profile
0000-0002-0099-3343
Current Organisation
Royal Brisbane and Women's Hospital
Does something not look right? The information on this page has been harvested from data sources that may not be up to date. We continue to work with information providers to improve coverage and quality. To report an issue, use the Feedback Form.
Publisher: Elsevier BV
Date: 2021
Publisher: Public Library of Science (PLoS)
Date: 12-02-2021
DOI: 10.1371/JOURNAL.PONE.0247056
Abstract: Older adults are at increased risk of pneumococcal disease. This work aims to evaluate whether there is any decrease in serum IgG against variants of the antigens Pneumococcal surface protein A (PspA) and Pneumococcal surface protein C (PspC) in healthy adults with increasing age. Levels of IgG against PspA and PspC variants were determined by ELISA in serum s les comparing volunteers 18–30 years of age with volunteers who were 50–70+ before and after an experimental pneumococcal colonization challenge. The serotype 6B strain used in the challenge belongs to a minor group of pneumococcal isolates expressing two PspC variants. There was a decrease in levels of IgG with increasing age for the most common PspA variants and for all PspC variants analyzed. No correlation was found between basal levels of IgG against these antigens and protection against colonization. There was an increase in levels of IgG against PspA variants that are more cross-reactive with the variant expressed by the challenge strain post challenge in younger in iduals who became colonized. Since the challenge strain used in our study expresses two different PspC variants, an increase in serum IgG against all PspC variants tested was observed in younger in iduals who became colonized. For some of the antigen variants tested, a decrease in serum IgG was observed in young volunteers who were challenged but did not become colonized. Serum IgG antibodies against PspA and PspC variants thus decrease with age in healthy adults, but there is no correlation between levels of IgG against these antigens and protection against human experimental colonization. Though no correlation between naturally induced serum IgG antibodies against PspA and PspC and protection against colonization was observed, these results do not rule out the protective potential of these antigens as vaccines against pneumococcal infections.
Publisher: Ovid Technologies (Wolters Kluwer Health)
Date: 03-2020
Publisher: Elsevier BV
Date: 04-2020
DOI: 10.1016/J.HRTHM.2019.10.025
Abstract: To facilitate catheter ablation of ventricular tachycardia (VT), we previously developed an automated method to identify sources of left ventricular (LV) activation in real time using 12-lead electrocardiography (ECG), the accuracy of which depends on acquisition of a complete electroanatomic (EA) map. The purpose of this study was to assess the feasibility of using a registered cardiac computed tomogram (CT) rather than an EA map to permit real-time localization and avoid errors introduced by incomplete maps. Before LV VT ablation, 10 patients underwent CT imaging and 3-dimensional reconstruction of the cardiac surface to create a triangle mesh surface, which was registered to the EA map during the procedure and imported into custom localization software. The software uses QRS integrals from leads III, V The VT exit site was identified for 20 VTs using activation and entrainment mapping, supplemented by pace-mapping at the scar margin. The automated localization software achieved incremental accuracy with additional pacing sites and had a mean localization error of 6.9 ± 5.7 mm for the 20 VTs. Patient-specific CT geometry is feasible for use in real-time automated localization of ventricular activation and may avoid reliance on a complete EA map.
Publisher: Oxford University Press (OUP)
Date: 20-02-2021
Abstract: Cardiac implantable electronic devices with device advisories have the potential of device malfunction. Remote monitoring (RM) of devices has been suggested to allow the identification of abnormal device performance and permit early intervention. We sought to describe the outcomes of patients with and without RM in devices subject to the Abbott Premature Battery Depletion (PBD) advisory with data from a Canadian registry. Patients with an Abbott device subject to the PBD advisory from nine implantable cardioverter defibrillator (ICD) implanting centres in Canada were included in the registry. The use of RM was identified from baseline and follow-up data in the registry. The primary outcome was detection of PBD and all-cause mortality. A total of 2666 patients were identified with a device subject to the advisory. In all, 1687 patients (63.2%) had RM at baseline. There were 487 deaths during follow-up. At a mean follow-up of 5.7 ± 0.7 years, mortality was higher in those without a remote monitor compared with RM at baseline (24.7% vs. 14.5% P & 0.001). Pre-mature battery depletion was identified in 36 patients (2.1%) with RM vs. 7 (0.7%) without RM (P = 0.004). Time to battery replacement was significantly reduced in patients on RM (median 5 vs. 13 days, P = 0.001). The use of RM in patients with ICD and cardiac resynchronization therapy under advisory improved detection of PBD, time to device replacement, and was associated with a reduction in all-cause mortality. The factors influencing the association with mortality are unknown and deserve further study.
Publisher: Elsevier BV
Date: 11-2020
No related grants have been discovered for Jason Davis.