ORCID Profile
0000-0002-6780-0059
Current Organisations
Fatima College of Health Sciences
,
Jordan University of Science and Technology
Does something not look right? The information on this page has been harvested from data sources that may not be up to date. We continue to work with information providers to improve coverage and quality. To report an issue, use the Feedback Form.
Publisher: Briefland
Date: 17-06-2018
Publisher: SAGE Publications
Date: 17-05-2018
Abstract: The study aims to assess the level of patients’ awareness and knowledge regarding radiation and dosage along with the associated risks from computed tomography (CT) scan. This cross-sectional study used questionnaires, which were distributed to the diagnostic imaging departments of six large local hospitals in Jordan between September 2014 and March 2015. A total of 600 patients completed the questionnaire, out of which, 52.33% of respondents were female and 47.6% male. The findings show insignificant effects of gender on patient’s knowledge ( P = .596) and significant effect of employment and profession on positive scores ( P = .000). Similarly, no statistical differences were found between gender and correct answers ( P = .707). This cohort of patients demonstrated a lack of awareness and knowledge about the use of ionizing radiation for diagnostic imaging. Thus, there may exist a similar lack of information that will require imaging professionals to raise patients’ awareness and offer them the appropriate information.
Publisher: Ovid Technologies (Wolters Kluwer Health)
Date: 09-2018
DOI: 10.1097/HP.0000000000000886
Abstract: Background: Radiologists are at higher risk of adverse health effects due to their occupational radiation exposure therefore, applying protection techniques is imperative. Studies on radiologists’ compliance in this regard are scarce. We aimed to assess compliance with radiation safety practices among radiologists. Methods: Questionnaires were distributed to radiologists in tertiary hospitals. The questionnaire was designed to assess compliance in three domains: using personal protective devices, using exposure-reduction techniques during fluoroscopic exposures, and using personal dose-monitoring devices. Descriptive analysis of the compliance was performed. Results: Sixty-two radiologists were included in the analysis. Use of leaded aprons and thyroid shields was commonplace, whereas only 3.2% ever use leaded eyeglasses. About half of the radiologists always considered reducing the time of exposure and avoided exposure by the primary beam, and the other half did that sometimes. Most of the radiologists (66.1%) always complied with reducing the number of unnecessary exposures, and the rest only complied sometimes. Most of the radiologists (93.5%) always used single personal dose-monitoring devices, most commonly at the neck level over the collar. There was no difference in compliance between different sexes, position descriptions, hospital types, hospital sizes, or years of experience. Conclusion: Future compliance improvement strategies for radiologists should focus on use of thyroid shields and leaded eyeglasses and use of exposure-reduction techniques during fluoroscopic operations.
Publisher: Elsevier BV
Date: 11-2017
DOI: 10.1016/J.RADI.2017.07.005
Abstract: Nosocomial infections add health-related and financial burdens on health systems. This study aims to evaluate the radiographers' knowledge of nosocomial infection control practices in Jordan. A cross-sectional questionnaire-based assessment was conducted. The main domains of the knowledge based test were the nature of nosocomial infections, standard precautions, and infection control practices specific to the radiology department. Comparison of knowledge among radiographers was assessed using the Student t-test and ANOVA. Multiple linear regression was used to find predictors of the knowledge score. The final analysis included 100 radiographers from educational, private, and public hospitals. Mean knowledge score was 66.2% (SD: 20.3%, range: 25.0-100%). Questions with the lowest correctly scored were about the main source of infections (17%), recapping used needles (27%), gloves use (27%), the necessity of using overshoes (26%) and a cap (26%) when there is a risk of biological fluid splashes, the necessity of using sterile gloves (7%) and protective masks (5%) during all invasive procedures, the manoeuvrability around a sterile field (54%), and the safety of passing the imaging plate to the scrub nurse in order to place it under the radiographer's direction (37%). Predictors of knowledge score were the academic degree and training status (R Knowledge of infection control practices among Jordanian radiographers was moderate. Future training should focus on handling used needles, the use of protective barriers, and the manoeuvrability around sterile fields. Improved academic curriculum and on-site training could enhance knowledge in infection control practices.