ORCID Profile
0000-0002-8115-0275
Current Organisations
University of Zurich
,
Balgrist University Hospital
,
ETH-Bereich Hochschulen
Does something not look right? The information on this page has been harvested from data sources that may not be up to date. We continue to work with information providers to improve coverage and quality. To report an issue, use the Feedback Form.
Publisher: Springer Science and Business Media LLC
Date: 09-02-2019
DOI: 10.1007/S00402-019-03137-3
Abstract: The purpose of this proof-of-concept study was to investigate the biomechanical performance of two surgical techniques, namely (1) the double Tight-Rope fixation with an additional acromioclavicular FiberTape fixation (DTRC) and (2) the fixation of the clavicle to the acromion and coracoid in a bipodal manner (Bipod) using a Poly-Tape and FiberTape. Both techniques intend to address vertical and horizontal instability after acromioclavicular dislocation. They were compared with the commonly used (3) double Tight-Rope (DTR) technique, which only stabilizes the clavicle to the coracoid. The acromioclavicular joint (ACJ) of 18 composite Sawbone shoulder specimens (6 per reconstruction group) were tested for posterosuperior elongation (70N cyclical load, 1500 cycles), load-to-failure and stiffness. After 1500 cycles, the DTRC, Bipod and DTR group showed an elongation of 0.45 mm (SD 0.14 mm), 1.19 mm (SD 0.54 mm), and 0.46 mm (SD 0.15 mm), respectively. Although the elongation of the Bipod group was increased when compared to the other two groups (Bipod versus DTRC p = 0.008 Bipod versus DTR p = 0.006), the difference was less than 0.7 mm. The DTRC showed a higher load-to-failure of 656.1N (SD 58.1 N) compared to the Bipod [531.1 N (SD 108.2N) (p = 0.039)] and DTR group [522.8 N (SD 32.8 N) (p = 0.033)]. The DTRC and the DTR group resulted in similar low elongation, while the elongation in the Bipod technique was slightly higher. Even though this difference of 0.7 mm shows statistical significance, it most likely has no clinical relevance. When testing in posterosuperior direction, which is the clinically relevant load vector, an additional fixation of the clavicle to the acromion did not reduce elongation in this study. It is, furthermore, questionable if the benefit of an increased load-to-failure in combination with no improvement in elongation and stiffness as seen in the DTRC group outweighs the possible risks and increased costs coming with the DTRC refixation.
Publisher: American Association for the Advancement of Science (AAAS)
Date: 24-02-2021
DOI: 10.1126/SCITRANSLMED.ABE5738
Abstract: The extracellular matrix protein SPARC modulates load sensing in tendons and is critical for tissue maturation and homeostasis.
Location: United States of America
No related grants have been discovered for Jess Snedeker.