ORCID Profile
0000-0003-2470-1031
Current Organisation
University of Oxford
Does something not look right? The information on this page has been harvested from data sources that may not be up to date. We continue to work with information providers to improve coverage and quality. To report an issue, use the Feedback Form.
Publisher: Springer Science and Business Media LLC
Date: 24-03-2020
DOI: 10.1038/S41598-020-62492-Z
Abstract: An amendment to this paper has been published and can be accessed via a link at the top of the paper.
Publisher: Elsevier BV
Date: 11-2017
DOI: 10.1016/J.JSE.2017.06.035
Abstract: Retearing after rotator cuff surgery is a major clinical problem. Numerous scaffolds are being used to try to reduce retear rates. However, few have demonstrated clinical efficacy. We hypothesize that this lack of efficacy is due to insufficient mechanical properties. Therefore, we compared the macro and nano/micro mechanical properties of 7 commercially available scaffolds to those of the human supraspinatus tendons, whose function they seek to restore. The clinically approved scaffolds tested were X-Repair, LARS ligament, Poly-Tape, BioFiber, GraftJacket, Permacol, and Conexa. Fresh frozen cadaveric human supraspinatus tendon s les were used. Macro mechanical properties were determined through tensile testing and rheometry. Scanning probe microscopy and scanning electron microscopy were performed to assess properties of materials at the nano/microscale (morphology, Young modulus, loss tangent). None of the scaffolds tested adequately approximated both the macro and micro mechanical properties of human supraspinatus tendon. Macroscale mechanical properties were insufficient to restore load-bearing function. The best-performing scaffolds on the macroscale (X-Repair, LARS ligament) had poor nano/microscale properties. Scaffolds approximating tendon properties on the nano/microscale (BioFiber, biologic scaffolds) had poor macroscale properties. Existing scaffolds failed to adequately approximate the mechanical properties of human supraspinatus tendons. Combining the macroscopic mechanical properties of a synthetic scaffold with the micro mechanical properties of biologic scaffold could better achieve this goal. Future work should focus on advancing techniques to create new scaffolds with more desirable mechanical properties. This may help improve outcomes for rotator cuff surgery patients.
Publisher: Springer Science and Business Media LLC
Date: 30-01-2020
DOI: 10.1038/S41598-020-58362-3
Abstract: Endometriosis is a common gynaecological disease of women in reproductive age, and is thought to arise from retrograde menstruation and implantation of endometrial tissue, mostly into the peritoneal cavity. The condition is characterized by a chronic, unresolved inflammatory process thereby contributing to pain as cardinal symptom in endometriosis. Elevated reactive oxygen species (ROS) and oxidative stress have been postulated as factors in endometriosis pathogenesis. We here set out for a systematic study to identify novel mechanisms and pathways relating to oxidative stress in ectopic peritoneal lesions. Using combined proteomic and transcriptomic approaches, we identified novel targets including upregulated pro-oxidative enzymes, such as amine oxidase 3/vascular adhesion protein 1 (AOC3/VAP1) as well as downregulated protective factors, in particular alkenal reductase PTGR1 and methionine sulfoxide reductase. Consistent with an altered ROS landscape, we observed hemoglobin / iron overload, ROS production and lipid peroxidation in ectopic lesions. ROS-derived 4-hydroxy-2-nonenal induced interleukin IL-8 release from monocytes. Notably, AOC3 inhibitors provoked analgesic effects in inflammatory pain models in vivo , suggesting potential translational applicability.
Location: United Kingdom of Great Britain and Northern Ireland
Location: United Kingdom of Great Britain and Northern Ireland
Location: United Kingdom of Great Britain and Northern Ireland
No related grants have been discovered for Stephanie Georgina Dakin.