ORCID Profile
0000-0003-0650-5889
Current Organisation
ETH Zurich
Does something not look right? The information on this page has been harvested from data sources that may not be up to date. We continue to work with information providers to improve coverage and quality. To report an issue, use the Feedback Form.
Publisher: Wiley
Date: 02-2009
DOI: 10.1002/JOR.20747
Abstract: Soft tissue damage has been observed in hip joints with pathological geometries. Our primary goal was to study the relationship between morphological variations of the bony components of the hip and resultant stresses within the soft tissues of the joint during routine daily activities. The secondary goal was to find the range of morphological parameters in which stresses are minimized. Computational models of normal and pathological joints were developed based on variations of morphological parameters of the femoral head (Alpha angle) and acetabulum (CE angle). The Alpha angle was varied between 40 degrees (normal joint) and 80 degrees (cam joint). The CE angle was varied between 0 degrees (dysplastic joint) and 40 degrees (pincer joint). Dynamic loads and motions for walking and standing to sitting were applied to all joint configurations. Contact pressures and stresses were calculated and crosscompared to evaluate the influence of morphology. The stresses in the soft tissues depended strongly on the head and acetabular geometry. For the dysplastic joint, walking produced high acetabular rim stresses. Conversely, for impinging joints, standing-to-sitting activities that involved extensive motion were critical, inducing excessive distortion and shearing of the tissue-bone interface. Zones with high von Mises stresses corresponded with clinically observed damage zones in the acetabular cartilage and labrum. Hip joint morphological parameters that minimized were 20 degrees <or= CE <or= 30 degrees and alpha <or= 50 degrees .
Publisher: Springer Science and Business Media LLC
Date: 27-11-2017
DOI: 10.1007/S10439-017-1952-Z
Abstract: The limitations of areal bone mineral density measurements for identifying at-risk in iduals have led to the development of alternative screening methods for hip fracture risk including the use of geometrical measurements from the proximal femur and subject specific finite element analysis (FEA) for predicting femoral strength, based on quantitative CT data (qCT). However, these methods need more development to gain widespread clinical applications. This study had three aims: To investigate whether proximal femur geometrical parameters correlate with obtained femur peak force during the impact testing to examine whether or not failure of the proximal femur initiates in the cancellous (trabecular) bone and finally, to examine whether or not surface fracture initiates in the places where holes perforate the cortex of the proximal femur. We found that cortical thickness around the trochanteric-fossa is significantly correlated to the peak force obtained from simulated sideways falling (R
Publisher: Elsevier BV
Date: 02-2018
DOI: 10.1016/J.JMBBM.2017.10.033
Abstract: Sideways falls are largely responsible for the highly prevalent osteoporotic hip fractures in today's society. These injuries are dynamic events, therefore dynamic FE models validated with dynamic ex vivo experiments provide a more realistic simulation than simple quasi-static analysis. Drop tower experiments using cadaveric specimens were used to identify the material mapping strategy that provided the most realistic mechanical response under impact loading. The present study tested the addition of compression-tension asymmetry, tensile bone damage, and cortical-specific strain rate dependency to the material mapping strategy of fifteen dynamic FE models of the proximal femur, and found improved correlations and reduced error for whole bone stiffness (R
Publisher: Springer Science and Business Media LLC
Date: 02-07-2018
DOI: 10.1007/S00586-018-5688-8
Abstract: Prolonged bed rest and microgravity in space cause intervertebral disc (IVD) degeneration. However, the underlying molecular mechanisms are not completely understood. Transient receptor potential canonical (TRPC) channels are implicated in mechanosensing of several tissues, but are poorly explored in IVDs. Primary human IVD cells from surgical biopsies composed of both annulus fibrosus and nucleus pulposus (passage 1-2) were exposed to simulated microgravity and to the TRPC channel inhibitor SKF-96365 (SKF) for up to 5 days. Proliferative capacity, cell cycle distribution, senescence and TRPC channel expression were analyzed. Both simulated microgravity and TRPC channel antagonism reduced the proliferative capacity of IVD cells and induced senescence. While significant changes in cell cycle distributions (reduction in G1 and accumulation in G2/M) were observed upon SKF treatment, the effect was small upon 3 days of simulated microgravity. Finally, downregulation of TRPC6 was shown under simulated microgravity. Simulated microgravity and TRPC channel inhibition both led to reduced proliferation and increased senescence. Furthermore, simulated microgravity reduced TRPC6 expression. IVD cell senescence and mechanotransduction may hence potentially be regulated by TRPC6 expression. This study thus reveals promising targets for future studies. These slides can be retrieved under Electronic Supplementary Material.
Publisher: Elsevier BV
Date: 07-2023
Publisher: Elsevier BV
Date: 11-2016
DOI: 10.1016/J.MEDENGPHY.2016.08.010
Abstract: Finite element analysis (FEA) of bones scanned with Quantitative Computed Tomography (QCT) can improve early detection of osteoporosis. The accuracy of these models partially depends on the assigned material properties, but anisotropy of the trabecular bone cannot be fully captured due to insufficient resolution of QCT. The inclusion of anisotropy measured from high resolution peripheral QCT (HR-pQCT) could potentially improve QCT-based FEA of the femur, although no improvements have yet been demonstrated in previous experimental studies. This study analyzed the effects of adding anisotropy to clinical resolution femur models by constructing six sets of FE models (two isotropic and four anisotropic) for each specimen from a set of sixteen femurs that were experimentally tested in sideways fall loading with a strain gauge on the superior femoral neck. Two different modulus-density relationships were tested, both with and without anisotropy derived from mean intercept length analysis of HR-pQCT scans. Comparing iso- and anisotropic models to the experimental data resulted in nearly identical correlation and highly similar linear regressions for both whole bone stiffness and strain gauge measurements. Anisotropic models contained consistently greater principal compressive strains, approximately 14% in magnitude, in certain internal elements located in the femoral neck, greater trochanter, and femoral head. In summary, anisotropy had minimal impact on macroscopic measurements, but did alter internal strain behavior. This suggests that organ level QCT-based FE models measuring femoral stiffness have little to gain from the addition of anisotropy, but studies considering failure of internal structures should consider including anisotropy to their models.
Publisher: Elsevier BV
Date: 2017
DOI: 10.1016/J.JMBBM.2016.10.002
Abstract: The purpose of this study was to load cadaveric vertebral bodies (n=6) in compression and compare the response, measured with digital image correlation (DIC) on the cortex, with the predicted response from specimen-specific vertebral finite element (FE) models. Five modulus-density relationships were evaluated, and for the strongest modulus-density relationship, the correlation between the DIC and FE displacements had R
Publisher: Elsevier BV
Date: 2015
DOI: 10.1016/J.JBIOMECH.2014.11.042
Abstract: Current screening techniques based on areal bone mineral density (aBMD) measurements are unable to identify the majority of people who sustain hip fractures. Biomechanical examination of such events may help determine what predisposes a hip to be susceptible to fracture. Recently, drop-tower simulations of in-vitro sideways falls have allowed the study of the mechanical response of the proximal human femur at realistic impact speeds. This technique has created an opportunity to validate explicit finite element (FE) models against dynamic test data. This study compared the outcomes of 15 human femoral specimens fractured using a drop tower with complementary specimen-specific explicit FE analysis. Correlation coefficient and root mean square error (RMSE) were found to be moderate for whole bone stiffness comparison (R(2)=0.3476 and 22.85% respectively). No correlation was found between experimentally and computationally predicted peak force, however, energy absorption comparison produced moderate correlation and RMSE (R(2)=0.4781 and 29.14% respectively). By comparing predicted strain maps to high speed video data we demonstrated the ability of the FE models to detect vulnerable portions of the bones. Based on our observations, we conclude that there exists a need to extend the current apparent level material models for bone to cover higher strain rates than previously tested experimentally.
Publisher: Elsevier BV
Date: 07-2016
DOI: 10.1016/J.MEDENGPHY.2016.03.006
Abstract: Contributing to slow advance of finite element (FE) simulations for hip fracture risk prediction, into clinical practice, could be a lack of consensus in the biomechanics community on how to map properties to the models. Thus, the aim of the present study was first, to systematically quantify the influence of the modulus-density relationship (E-ρ) and the material mapping method (MMM) on the predicted mechanical response of the proximal femur in a side-ways fall (SWF) loading configuration and second, to perform a model-to-model comparison of the predicted mechanical response within the femoral neck for all the specimens tested in the present study, using three different modelling techniques that have yielded good validation outcome in terms of surface strain prediction and whole bone response according to the literature. We found the outcome to be highly dependent on both the E-ρ relationship and the MMM. In addition, we found that the three modelling techniques that have resulted in good validation outcome in the literature yielded different principal strain prediction both on the surface as well as internally in the femoral neck region of the specimens modelled in the present study. We conclude that there exists a need to carry out a more comprehensive validation study for the SWF loading mode to identify which combination of MMMs and E-ρ relationship leads to the best match for whole bone and local mechanical response. The MMMs tested in the present study have been made publicly available at ome/mitk-gem.
No related grants have been discovered for Stephen Ferguson.