ORCID Profile
0000-0002-1680-4287
Current Organisation
The University of Auckland
Does something not look right? The information on this page has been harvested from data sources that may not be up to date. We continue to work with information providers to improve coverage and quality. To report an issue, use the Feedback Form.
Publisher: Elsevier BV
Date: 2019
DOI: 10.1016/J.JBIOMECH.2018.10.027
Abstract: Achilles tendon material properties and geometry are altered in Achilles tendinopathy. The purpose of this study was to determine the relative contributions of altered material properties and geometry to free Achilles tendon stress distribution during a sub-maximal contraction in tendinopathic relative to healthy tendons. Tendinopathic (n = 8) and healthy tendons (n = 8) were imaged at rest and during a sub-maximal voluntary isometric contraction using three-dimensional freehand ultrasound. Images were manually segmented and used to create subject-specific finite element models. The resting cross-sectional area of the free tendon was on average 31% greater for the tendinopathic compared to healthy tendons. Material properties for each tendon were determined using a numerical parameter optimisation approach that minimised the difference in experimentally measured longitudinal strain and the strain predicted by the finite element model under submaximal loading conditions for each tendon. The mean Young's modulus for tendinopathic tendons was 53% lower than the corresponding control value. Finite element analyses revealed that tendinopathic tendons experience 24% less stress under the same submaximal external loading conditions compared to healthy tendons. The lower tendon stress in tendinopathy was due to a greater influence of tendon cross-sectional area, which alone reduced tendon stress by 30%, compared to a lower Young's modulus, which alone increased tendon stress by 8%. These findings suggest that the greater tendon cross-sectional area observed in tendinopathy compensates for the substantially lower Young's modulus, thereby protecting pathological tendon against excessive stress.
Publisher: ASME International
Date: 24-09-2014
DOI: 10.1115/1.4028522
Abstract: Periprosthetic osteolysis in the retroacetabular region with cancellous bone loss is a recognized phenomenon in the long-term follow-up of total hip replacement. The effects on load transfer in the presence of defects are less well known. A validated, patient-specific, 3D finite element (FE) model of the pelvis was used to assess changes in load transfer associated with periprosthetic osteolysis adjacent to a cementless total hip arthroplasty (THA) component. The presence of a cancellous defect significantly increased (p 0.05) von Mises stress in the cortical bone of the pelvis during walking and a fall onto the side. At loads consistent with single leg stance, this was still less than the predicted yield stress for cortical bone. During higher loads associated with a fall onto the side, highest stress concentrations occurred in the superior and inferior pubic rami and in the anterior column of the acetabulum with larger cancellous defects.
Publisher: Springer Science and Business Media LLC
Date: 10-04-2015
DOI: 10.1007/S10237-015-0668-Y
Abstract: This study presents an evaluation of the role that cartilage fibre 'split line' orientation plays in informing femoral cartilage stress patterns. A two-stage model is presented consisting of a whole knee joint coupled to a tissue-level cartilage model for computational efficiency. The whole joint model may be easily customised to any MRI or CT geometry using free-form deformation. Three 'split line' patterns (medial-lateral, anterior-posterior and random) were implemented in a finite element model with constitutive properties referring to this 'split line' orientation as a finite element fibre field. The medial-lateral orientation was similar to anatomy and was derived from imaging studies. Model predictions showed that 'split lines' are formed along the line of maximum principal strains and may have a biomechanical role of protecting the cartilage by limiting the cartilage deformation to the area of higher cartilage thickness.
Publisher: Human Kinetics
Date: 10-2023
Abstract: In this narrative review, we explore developments in the field of computational musculoskeletal model personalization using the Physiome and Musculoskeletal Atlas Projects. Model geometry personalization statistical shape modeling and its impact on segmentation, classification, and model creation are explored. Ex les include the trapeziometacarpal and tibiofemoral joints, Achilles tendon, gastrocnemius muscle, and pediatric lower limb bones. Finally, a more general approach to model personalization is discussed based on the idea of multiscale personalization called scaffolds.
Publisher: Springer Science and Business Media LLC
Date: 14-09-2018
DOI: 10.1038/S41598-018-31587-Z
Abstract: The Achilles tendon (AT), the largest tendon in the human body has a unique structural feature, that is the fascicles in the AT display spiral twist. However, their functional and structural roles are still unclear. We used subject-specific computational models and tissue mechanical experiment to quantitatively characterize the role of fascicle twist in the Achilles tendon. Ten subject-specific finite element (FE) models of the Achilles tendon were developed from ultrasound images. Fascicle twist was implemented in these models using the material coordinate system available in our FE framework. Five different angles (0~60°) were implemented and material property optimization was performed for each of them (total 50 sets) using results from uniaxial stretch experiment. We showed that fascicle twist allows for even distribution of stress across the whole tendon, thus improving tissue strength. The predicted rupture load increased up to 40%. A number of connective tissues display similar fascicle twists in their structure. The resulting non-uniform strain distribution has been hypothesized as a primary factor in tissue degeneration and injuries. Therefore, our technique will be used to design biomechanically informed training and rehabilitation protocols for management of connective tissue injuries and degeneration.
Publisher: IEEE
Date: 08-2012
Publisher: BMJ
Date: 20-07-2019
Publisher: Institute of Electrical and Electronics Engineers (IEEE)
Date: 12-2011
Publisher: Springer International Publishing
Date: 21-06-2017
Publisher: Elsevier BV
Date: 05-2017
DOI: 10.1016/J.JBIOMECH.2017.02.031
Abstract: This study used subject-specific measures of three-dimensional (3D) free Achilles tendon geometry in conjunction with a finite element method to investigate the effect of variation in subject-specific geometry and subject-specific material properties on tendon stress during submaximal isometric loading. Achilles tendons of eight participants (Aged 25-35years) were scanned with freehand 3D ultrasound at rest and during a 70% maximum voluntary isometric contraction. Ultrasound images were segmented, volume rendered and transformed into subject-specific 3D finite element meshes. The mean (±SD) lengths, volumes and cross-sectional areas of the tendons at rest were 62±13mm, 3617±984mm
Publisher: British Editorial Society of Bone & Joint Surgery
Date: 11-2018
DOI: 10.1302/0301-620X.100B11.BJJ-2018-0092.R2
Abstract: Osteolysis, secondary to local and systemic physiological effects, is a major challenge in total hip arthroplasty (THA). While osteolytic defects are commonly observed in long-term follow-up, how such lesions alter the distribution of stress is unclear. The aim of this study was to quantitatively describe the biomechanical implication of such lesions by performing subject-specific finite-element (FE) analysis on patients with osteolysis after THA. A total of 22 hemipelvis FE models were constructed in order to assess the transfer of load in 11 patients with osteolysis around the acetabular component of a THA during slow walking and a fall onto the side. There were nine men and two women. Their mean age was 69 years (55 to 81) at final follow-up. Changes in peak stress values and loads to fracture in the presence of the osteolytic defects were measured. The von Mises stresses were increased in models of those with and those without defects for both loading scenarios. Although some regions showed increases in stress values of up to 100%, there was only a moderate 11.2% increase in von Mises stress in the series as a whole. The site of fracture changed in some models with lowering of the load to fracture by 500 N. The most common site of fracture was the pubic ramus. This was more frequent in models with larger defects. We conclude that cancellous defects cause increases in stress within cortical structures. However, these are likely to lead to a modest decrease in the load to fracture if the defect is large ( 20cm 3 ) or if the patient is small with thin cortical structures and low bone mineral density. Cite this article: Bone Joint J 2018 -B:1455–62.
Publisher: Wiley
Date: 25-08-2014
DOI: 10.1002/CNM.2586
Abstract: A modelling framework using the international Physiome Project is presented for evaluating the role of muscles on acetabular stress patterns in the natural hip. The novel developments include the following: (i) an efficient method for model generation with validation (ii) the inclusion of electromyography-estimated muscle forces from gait and (iii) the role that muscles play in the hip stress pattern. The 3D finite element hip model includes anatomically based muscle area attachments, material properties derived from Hounsfield units and validation against an Instron compression test. The primary outcome from this study is that hip loading applied as anatomically accurate muscle forces redistributes the stress pattern and reduces peak stress throughout the pelvis and within the acetabulum compared with applying the same net hip force without muscles through the femur. Muscle forces also increased stress where large muscles have small insertion sites. This has implications for the hip where bone stress and strain are key excitation variables used to initiate bone remodelling based on the strain-based bone remodelling theory. Inclusion of muscle forces reduces the predicted sites and degree of remodelling. The secondary outcome is that the key muscles that influenced remodelling in the acetabulum were the rectus femoris, adductor magnus and iliacus.
Publisher: Frontiers Media SA
Date: 12-08-2020
No related grants have been discovered for Vickie Bo Kyung Shim.