Mechanical Engineering | Mechanical Engineering | Cardiology (Incl. Cardiovascular Diseases) | Electrical Engineering
Appliances and electrical machinery and equipment | Scientific instrumentation | Machinery and equipment not elsewhere classified |
Publisher: Emerald
Date: 29-03-2021
Abstract: Additive manufacturing (AM) techniques have been developed to rapidly produce custom designs from a multitude of materials. Bonded permanent magnets (PMs) have been produced via several AM techniques to allow for rapid manufacture of complex geometries. These magnets, however, tend to suffer from lower residual induction than the industry standard of injection moulding primarily due to the lower packing density of the magnetic particles and secondly due to the feedstock consisting of neodymium-iron-boron (Nd-Fe-B) powder with isotropic magnetic properties. As there is no compaction during most AM processes, increasing the packing density is very difficult and therefore the purpose of this study was to increase the magnetic properties of the PMs without increasing the part density. Accordingly, this research investigates the use of anisotropic NdFeB feedstock coupled with an in-situ alignment fixture into an AM process known as selective laser sintering (SLS) to increase the magnetic properties of AM magnets. A Helmholtz coil array was added to an SLS machine and used to expose each powder layer during part fabrication to a near-uniform magnetic field of 20.4 mT prior to consolidation by the laser. Permeagraph measurements of the parts showed that the alignment field introduced residual induction anisotropy of up to 46.4 ± 2.2% when measured in directions parallel and perpendicular to the alignment field. X-ray diffraction measurements also demonstrated a convergence of the orientation of the crystals when the magnets were processed in the presence of the alignment field. A novel active alignment fixture for SLS was introduced and was experimentally shown to induce anisotropy in bonded PMs. Thus demonstrating a new method for the enhancement in energy density of PMs produced via AM methods.
Publisher: Wiley
Date: 10-2008
DOI: 10.1111/J.1525-1594.2008.00629.X
Abstract: The purpose of this investigation was to design a novel magnetic drive and bearing system for a new centrifugal rotary blood pump (CRBP). The drive system consists of two components: (i) permanent magnets within the impeller of the CRBP and (ii) the driving electromagnets. Orientation of the magnets varies from axial through to 60 degrees included out-lean (conical configuration). Permanent magnets replace the electromagnet drive to allow easier characterization. The performance characteristics tested were the axial force of attraction between the stator and rotor at angles of rotational alignment, Ø, and the corresponding torque at those angles. The drive components were tested for various magnetic cone angles, theta. The test was repeated for three backing conditions: (i) non-backed (ii) steel-cupped and (iii) steel plate back-iron, performed on an Instron tensile testing machine. Experimental results were expanded upon through finite element and boundary element analysis (BEM). The force/torque characteristics were maximal for a 12-magnet configuration at 0 degree cone angle with steel-back iron (axial force = 60 N, torque = 0.375 Nm). BEM showed how introducing a cone angle increases the radial restoring force threefold while not compromising axial bearing force. Magnets in the drive system may be orientated not only to provide adequate coupling to drive the CRBP, but to provide significant axial and radial bearing forces capable of withstanding over 100 m/s(2) shock excitation on the impeller. Although the 12 magnet 0 degree (theta) configuration yielded the greatest force/torque characteristic, this was seen as potentially unattractive as this magnetic cone angle yielded poor radial restoring force characteristics.
Publisher: Trans Tech Publications, Ltd.
Date: 02-2011
DOI: 10.4028/WWW.SCIENTIFIC.NET/AMR.189-193.3672
Abstract: Pulsed Nd:YAG has been adopted successfully in welding process of thin (0.7 mm) Ti6Al4V. Laser welding of such thin sheet requires a small focal spot, good laser beam quality and fast travel speed, since too much heat generation can cause distortion for thin sheet weld. The microstructures of Ti6Al4V were complex and strongly affected the mechanical properties. These structures include: α´ martensite, metastable β, Widmanstätten, bimodal, lamellar and equiaxed microstructure. Bimodal and Widmanstätten structures exhibit a good-balance between strength and ductility. The microstructure of pulsed Nd:YAG welded Ti6Al4V was primarily α´ martensite, which showed the lowest ductility but not significantly high strength. A heat treatment at 950 followed by furnace cooling can transform the microstructure in the weld from α´ martensite structure into Widmanstätten structure.
Publisher: SAGE Publications
Date: 23-06-2010
Abstract: Various micro-radial compressor configurations were investigated using one-dimensional meanline and computational fluid dynamics (CFD) techniques for use in a micro gas turbine (MGT) domestic combined heat and power (DCHP) application. Blade backsweep, shaft speed, and blade height were varied at a constant pressure ratio. Shaft speeds were limited to 220 000 r/min, to enable the use of a turbocharger bearing platform. Off-design compressor performance was established and used to determine the MGT performance envelope this in turn was used to assess potential cost and environmental savings in a heat-led DCHP operating scenario within the target market of a detached family home. A low target-stage pressure ratio provided an opportunity to reduce diffusion within the impeller. Critically for DCHP, this produced very regular flow, which improved impeller performance for a wider operating envelope. The best performing impeller was a low-speed, 170 000 r/min, low-backsweep, 15° configuration producing 71.76 per cent stage efficiency at a pressure ratio of 2.20. This produced an MGT design point system efficiency of 14.85 per cent at 993 W, matching prime movers in the latest commercial DCHP units. Cost and CO 2 savings were 10.7 per cent and 6.3 per cent, respectively, for annual power demands of 17.4 MWht and 6.1 MWhe compared to a standard condensing boiler (with grid) installation. The maximum cost saving (on design point) was 14.2 per cent for annual power demands of 22.62 MWht and 6.1 MWhe corresponding to an 8.1 per cent CO 2 saving. When sizing, maximum savings were found with larger heat demands. When sized, maximum savings could be made by encouraging more electricity export either by reducing household electricity consumption or by increasing machine efficiency.
Publisher: Elsevier BV
Date: 08-2019
Publisher: MDPI AG
Date: 04-07-2020
DOI: 10.3390/PROSTHESIS2030014
Abstract: Nerve prostheses are widely utilized to reconstruct segmental (gap) defects in peripheral nerves as an alternative to nerve grafting. However, with increasing gap length, the effectiveness of a nerve prosthesis becomes sub-optimal, which subsequently has made repairing larger gaps in peripheral nerves a significant challenge in the field of regenerative medicine. Recently, the structure of nerve prostheses has been significantly revised, which interestingly, has provided a promising avenue for the housing and proliferation of supportive cells. In this systematic review, cell implantation in synthetic nerve prostheses to enhance the regenerative capability of an injured nerve with a focus on identifying the cell type and mode of cell delivery is discussed. Of interest are the studies employing supportive cells to bridge gaps greater than 10 mm without the aid of nerve growth factors. The results have shown that cell therapy in conjunction with nerve prostheses becomes inevitable and has dramatically boosted the ability of these prostheses to maintain sustainable nerve regeneration across larger gaps and helped to attain functional recovery, which is the ultimate goal. The statistical analysis supports the use of differentiated bone-marrow-derived mesenchymal stem cells suspended in oxygen-carrying hydrogels in chitosan prostheses for bridging gaps of up to 40 mm however, based on the imperfect repair outcomes, nerve grafting should not yet be replaced altogether.
Publisher: Wiley
Date: 16-06-2017
DOI: 10.1111/AOR.12919
Abstract: Rotary blood pumps (RBPs) are used for mechanical circulatory support in heart failure patients but exhibit a reduced response to preload changes, which can lead to ventricular suction events. A passive control system, in the form of a compliant inflow cannula (IC), has been developed to mitigate suction, although this device may cause significant hemolysis. This study compared the incidence of mechanically induced hemolysis of two compliant IC designs (strutted and nonstrutted) with a rigid IC (control) in a blood circulation loop over 90 min. The nonstrutted compliant IC introduced high frequency and high litude oscillations in RBP inlet pressure and RBP IC resistance. These oscillations were correlated with a significant increase in plasma-free hemoglobin (pfHb) and hemolysis: pfHb increased to 2.005 ± 0.665 g/L, while normalized index of hemolysis (NIH) and modified index of hemolysis (MIH) increased to 0.04945 ± 0.01276 g/100 L and 4.0505 ± 0.6589 after 90 min (P < 0.05). In contrast, the strutted compliant IC performed similar to the clinically utilized rigid IC and did not increase pfHb (0.300 ± 0.090 and 0.320 ± 0.171 g/L, respectively) and rate of hemolysis (NIH 0.00435 ± 0.00155 and 0.00543 ± 0.00371 g/100 L MIH 0.3896 ± 0.1749 and 0.4261 ± 0.2792, respectively) within the RBP circuit. These data indicated that strutted, compliant ICs meet the hemocompatibility of clinically used rigid ICs while also offering a potential solution to prevent ventricular suction events.
Publisher: Emerald
Date: 02-1998
Publisher: Elsevier BV
Date: 1995
DOI: 10.1016/0142-9612(95)92124-O
Abstract: This paper reports some of the ways in which biomaterial considerations have influenced the design, development and construction methods for a prototype conduit valve prosthesis in which the valve body is made from alumina. This material is used principally for its ability to grow and support a thin (< 0.1 mm) tissue covering on the surfaces in contact with the blood. This non-vascular covering does not interfere with the operation of the valve, but is thick enough to camouflage the underlying surface from any further interaction with the blood. This is important for any conduit valve because of the large internal surface area, but would be especially beneficial for children if it could obviate the need for chronic anticoagulation.
Publisher: Wiley
Date: 03-2004
Publisher: Wiley
Date: 25-08-2020
DOI: 10.1111/MICC.12652
Publisher: Wiley
Date: 06-09-2017
DOI: 10.1111/AOR.12997
Abstract: Patients receiving mechanical circulatory support often present with heightened inflammation and free radical production associated with pre-existing conditions in addition to that which is due to blood interactions with nonbiological surfaces. The aim of this experimental laboratory study was to assess the deformability of red blood cells (RBC) previously exposed to oxygen free radicals and determine the susceptibility of these cells to mechanical forces. In the present study, RBC from 15 healthy donors were washed and incubated for 60 min at 37°C with 50 µM phenazine methosulfate (PMS an agent that generates superoxide within RBC). Incubated RBC and negative controls were assessed for their deformability and susceptibility to mechanical damage (using ektacytometry) prior to the application of shear stress, and also following exposure to 25 different shear conditions of varied magnitudes (shear stress 1, 4, 16, 32, 64 Pa) and durations (1, 4, 16, 32, 64 s). The salient findings demonstrate that incubation with PMS impaired important indices of RBC deformability indicating altered cell mechanics by ∼19% in all conditions (pre- and postexposure to shear stress). The typical trends in shear-mediated changes in RBC susceptibility to mechanical damage, following conditioning shear stresses, were maintained for PMS incubated and control conditions. We demonstrated that free radicals hinder the ability of RBC to deform however, RBC retained their typical mechanical response to shear stress, albeit at a decreased level compared with control following exposure to PMS. Our findings also indicate that low shear exposure may decrease cell sensitivity to mechanical damage upon subsequent shear stress exposures. As patients receiving mechanical circulatory support have elevated exposure to free radicals (which limits RBC deformability), concomitant exposure to high shear environments needs to be minimized.
Publisher: Wiley
Date: 19-11-2004
DOI: 10.1111/J.1525-1594.2004.07348.X
Abstract: The VentrAssist implantable rotary blood pump, intended for long-term ventricular assist, is under development and is currently being tested for its rotor-dynamic stability. The pump consists of a shaftless impeller, which also acts as the rotor of the brushless DC motor. The impeller remains passively suspended in the pump cavity by hydrodynamic forces, which result from the small clearances between the outside surfaces of the impeller and the pump cavity. These small clearances range from approximately 50 microm to 230 microm in size in the version of pump reported here. This article presents experimental investigation into the dynamic characteristics of the impeller-bearing-pump housing system of the rotary blood pump for increasing pump speeds at different flow rates. The pump was mounted on a suspension system consisting of a platform and springs, where the natural frequency and d ing ratio for the suspension system were determined. Real-time measurements of the impeller's displacement were performed using Hall effect sensors. A vertical disturbance force was exerted onto the pump housing, causing the impeller to be displaced in vertical direction from its dynamic equilibrium position within the pump cavity. The impeller displacement was represented by a decaying sine wave, which indicated the impeller restoring to its equilibrium position. From the decaying sine wave the natural frequency and stiffness coefficient of the system were determined. Furthermore, the logarithmic decrement method was used to determine the d ing ratio and eventually the d ing coefficient of the system. Results indicate that stiffness and d ing coefficients increased as flow rate and pump speed increased, representing an increase in stability with these changing conditions. However, pump speed had a greater influence on the stiffness and d ing coefficients than flow rate did, which was evident through dynamic analysis. Overall the experimental method presented in this article was successful in determining the dynamic characteristics of the system.
Publisher: Wiley
Date: 10-2018
DOI: 10.1111/AOR.13361
Publisher: Wiley
Date: 09-2014
DOI: 10.1111/AOR.12395
Abstract: It has been shown that left ventricular assist devices (LVADs) increase the survival rate in end-stage heart failure patients. However, there is an ongoing demand for an increased quality of life, fewer adverse events, and more physiological devices. These challenges necessitate new approaches during the design process. In this study, computational fluid dynamics (CFD), lumped parameter (LP) modeling, mock circulatory loops (MCLs), and particle image velocimetry (PIV) are combined to develop a numerical Pump Testing Framework (nPTF) capable of analyzing local flow patterns and the systemic response of LVADs. The nPTF was created by connecting a CFD model of the aortic arch, including an LVAD outflow graft to an LP model of the circulatory system. Based on the same geometry, a three-dimensional silicone model was crafted using rapid prototyping and connected to an MCL. PIV studies of this setup were performed to validate the local flow fields (PIV) and the systemic response (MCL) of the nPTF. After validation, different outflow graft positions were compared using the nPTF. Both the numerical and the experimental setup were able to generate physiological responses by adjusting resistances and systemic compliance, with mean aortic pressures of 72.2-132.6 mm Hg for rotational speeds of 2200-3050 rpm. During LVAD support, an average flow to the distal branches (cerebral and subclavian) of 24% was found in the experiments and the nPTF. The flow fields from PIV and CFD were in good agreement. Numerical and experimental tools were combined to develop and validate the nPTF, which can be used to analyze local flow fields and the systemic response of LVADs during the design process. This allows analysis of physiological control parameters at early development stages and may, therefore, help to improve patient outcomes.
Publisher: Medknow
Date: 2019
Publisher: Walter de Gruyter GmbH
Date: 12-2006
DOI: 10.1515/JIB-2006-39
Abstract: Bioinformatics blossomed with research developments in molecular biology. But as the focus of research moves back up the physical scale to the biology of whole multicellular organisms, there are new integration challenges. Data integration is a perennial theme that will not be explored here. Rather, we outline a survey of the types of data generated in whole organisms, putting particular emphasis on complex image capture, management and analysis, bio-systems modelling techniques at this higher scale, and approaches to integrating models across these physical scales. This change in biological focus raises certain challenges, one of which may be the need to retrain bioinformaticians in sciences pertaining to whole plants and animals.
Publisher: IEEE
Date: 07-2018
Publisher: Elsevier BV
Date: 11-2018
DOI: 10.1016/J.MVR.2018.05.008
Abstract: Circulation of blood depends, in part, on the ability of red blood cells (RBCs) to aggregate, disaggregate, and deform. The primary intrinsic disaggregating force of RBCs is derived from their electronegativity, which is largely determined by sialylated glycoproteins on the plasma membrane. Given supraphysiological shear exposure - even at levels below those which induce hemolysis - alters cell morphology, we hypothesized that exposure to supraphysiological and subhemolytic shear would cleave membrane-bound sialic acid, altering the electrochemical and physical properties of RBCs, and thus increase RBC aggregation. Isolated RBCs from healthy donors (n = 20) were suspended in polyvinylpyrrolidinone. Using a Poiseuille shearing system, RBC suspensions were exposed to 125 Pa for 1.5 s for three duty-cycles. Following the first and third shear duty-cycle, s les were assessed for: RBC aggregation the ability of RBCs to aggregate independent of plasma ("aggregability") disaggregation shear rate membrane-bound sialic acid content, and cell electrophoretic mobility. Initial shear exposure significantly increased RBC aggregation, aggregability, and the shear required for rouleaux dispersion. Sialic acid concentration significantly decreased on isolated RBC membranes ghosts, and increased in the supernatant following shear. Initial shear exposure decreased the electrophoretic mobility of RBCs, decreasing the electronegative charge from -15.78 ± 0.31 to -7.55 ± 0.21 mV. Three exposures to the shear duty-cycle did not further compound altered RBC measures. A single exposure to supraphysiological and subhemolytic shear significantly decreased the electrochemical charge of the RBC membrane, concurrently increasing cell aggregation/aggregability. The cascading implications of hyperaggregation appears to potentially explain the ischemia-associated complications commonly reported following mechanical circulatory support.
Publisher: Wiley
Date: 09-2016
DOI: 10.1111/AOR.12827
Abstract: Unlike the earlier reciprocating volume displacement-type pumps, rotary blood pumps (RBPs) typically operate at a constant rotational speed and produce continuous outflow. When RBP technology is used in constructing a total artificial heart (TAH), the pressure waveform that the TAH produces is flat, without the rise and fall associated with a normal arterial pulse. Several studies have suggested that pulseless circulation may impair microcirculatory perfusion and the autoregulatory response and may contribute to adverse events such as gastrointestinal bleeding, arteriovenous malformations, and pump thrombosis. It may therefore be beneficial to attempt to reproduce pulsatile output, similar to that generated by the native heart, by rapidly modulating the speed of an RBP impeller. The choice of an appropriate speed profile and control strategy to generate physiologic waveforms while minimizing power consumption and blood trauma becomes a challenge. In this study, pump operation modes with six different speed profiles using the BiVACOR TAH were evaluated in vitro. These modes were compared with respect to: hemodynamic pulsatility, which was quantified as surplus hemodynamic energy (SHE) maximum rate of change of pressure (dP/dt) pulse power index and motor power consumption as a function of pulse pressure. The results showed that the evaluated variables underwent different trends in response to changes in the speed profile shape. The findings indicated a possible trade-off between SHE levels and flow rate pulsatility related to the relative systolic duration in the speed profile. Furthermore, none of the evaluated measures was sufficient to fully characterize hemodynamic pulsatility.
Publisher: ASME International
Date: 17-01-2018
DOI: 10.1115/1.4038429
Abstract: Rotary blood pumps (RBPs) used for mechanical circulatory support of heart failure patients cannot passively change pump flow sufficiently in response to frequent variations in preload induced by active postural changes. A physiological control system that mimics the response of the healthy heart is needed to adjust pump flow according to patient demand. Thus, baseline data are required on how the healthy heart and circulatory system (i.e., heart rate (HR) and cardiac output (CO)) respond. This study investigated the response times of the healthy heart during active postural changes (supine-standing-supine) in 50 healthy subjects (27 male/23 female). Early response times (te) and settling times (ts) were calculated for HR and CO from data continuously collected with impedance cardiography. The initial circulatory response of HR and CO resulted in te of 9.0–11.7 s when standing up and te of 4.7–5.7 s when lying back down. Heart rate and CO settled in ts of 50.0–53.6 s and 46.3–58.2 s when standing up and lying down, respectively. In conclusion, when compared to active stand up, HR and CO responded significant faster initially when subjects were lying down (p 0.05) there were no significant differences in response times between male and female subjects. These data will be used during evaluation of physiological control systems for RBPs, which may improve patient outcomes for end-stage heart failure patients.
Publisher: Informa UK Limited
Date: 08-1994
Publisher: IEEE
Date: 05-2011
Publisher: IEEE
Date: 08-2014
Publisher: American Scientific Publishers
Date: 12-2013
Publisher: Elsevier BV
Date: 10-2020
Publisher: Wiley
Date: 25-07-2019
DOI: 10.1111/AOR.13510
Abstract: Rotary ventricular assist devices (VADs) operated clinically under constant speed control (CSC) cannot respond adequately to changes in patient cardiac demand, resulting in sub-optimal VAD flow regulation. Starling-like control (SLC) of VADs mimics the healthy ventricular flow regulation and automatically adjusts VAD speed to meet varying patient cardiac demand. The use of a fixed control line (CL - the relationship between ventricular preload and VAD flow) limits the flow regulating capability of the controller, especially in the case of exercise. Adaptive SLC (ASLC) overcomes this limitation by allowing the controller to adapt the CL to meet a erse range of circulatory conditions. This study evaluated ASLC, SLC and CSC in a biventricular supported mock circulation loop under the simulated conditions of exercise, sleep, fluid loading and systemic hypertension. Each controller was evaluated on its ability to remain within predefined limits of VAD flow, preload, and afterload. The ASLC produced superior cardiac output (CO) during exercise (10.1 L/min) compared to SLC (7.3 L/min) and CSC (6.3 L/min). The ASLC produced favourable haemodynamics during sleep, fluid loading and systemic hypertension and could remain within a predefined haemodynamic range in three out of four simulations, suggesting improved haemodynamic performance over SLC and CSC.
Publisher: MDPI AG
Date: 30-07-2020
DOI: 10.3390/EN13153907
Abstract: Power quality and energy efficiency are of great importance in motor control. The motor of any medical device needs to have a smooth torque and minimal vibration in order to maximise its energy efficiency and patient comfort. Furthermore, in rotary blood pumps, excessive energy wasted due to vibration is converted into uncontrolled movement of the mechanical parts and thus could reduce the life of the motor-pump. Besides mechanical or hydraulic origin, one of the causes of vibration in any pump is torque ripple resulting from motor phase commutation. In this paper, using relevant equipment, two extreme scenarios were examined for vibration and electrical efficiency comparison due to power quality in a blood pump: one trapezoidal control with a trapezoidal phase current output the other a field oriented control (FOC) with a non-distorted sinusoidal phase current. The test motor-pump was the Arteriovenous Fistula Eligibility (AFE) System that is used prior to haemodialysis. The trapezoidal technique was implemented utilising the Allegro a4941 fan driver (Allegro Microsystem, 2012), and the FOC technique was implemented using the Texas Instrument digital signal processor (TMS320F28335). The aim was to reduce the energy wasted over vibration, and to achieve smooth operation of the AFE System. Vibration was measured with a one-axis accelerometer results showed considerably lower vibration due to less current ripple associated with the FOC control as well as lower power consumption.
Publisher: Springer Netherlands
Date: 1999
Publisher: Wiley
Date: 29-12-2020
DOI: 10.1111/AOR.13877
Abstract: Despite technological advances in ventricular assist devices (VADs) to treat end‐stage heart failure, hemocompatibility remains a constant concern, with supraphysiological shear stresses an unavoidable reality with clinical use. Given that impeller rotational speed is related to the instantaneous shear within the pump housing, it is plausible that the modulation of pump speed may regulate peak mechanical shear stresses and thus ameliorate blood damage. The present study investigated the hemocompatibility of the HeartWare HVAD in three configurations typical of clinical applications: standard systemic support left VAD (LVAD), pediatric support LVAD, and pulmonary support right VAD (RVAD) conditions. Two ex vivo mock circulation blood loops were constructed using explanted HVADs, in which pump speed and external loop resistance were manipulated to reflect the flow rates and differential pressures reported in configurations for standard adult LVAD (at 3150 rev⸱min −1 ), pediatric LVAD (at 2400 rev⸱min −1 ), and adult RVAD (at 1900 rev⸱min −1 ). Using bovine blood, the mock circulation blood loops were tested at 37°C over a period of 6 hours (consistent with ASTM F1841‐97) and compared with static control. Hemocompatibility assessments were conducted for each test condition, examining hematology, hemolysis (absolute and normalized index), osmotic fragility, and blood viscosity. Regardless of configuration, continuous exposure of blood to the VAD over the 6‐hour period significantly altered hematological and rheological blood parameters, and induced increased hemolysis when compared with a static control s le. Comparison of the three operational VAD configurations identified that the adult LVAD condition—associated with the highest pump speed, flow rate, and differential pressure across the pump—resulted in increased normalized hemolysis index (NIH 0.07) when compared with the lower pump speed “off‐label” counterparts (NIH of 0.04 in pediatric LVAD and 0.01 in adult RVAD configurations). After normalizing blood residence times between configurations, pump speed was identified as the primary determinant of accumulated blood damage plausibly, blood damage could be limited by restricting pump speed to the minimum required to support matched cardiac output, but not beyond.
Publisher: IEEE
Date: 11-2019
Publisher: Wiley
Date: 03-02-2020
DOI: 10.1111/AOR.13636
Abstract: Controlled and repeatable in vitro evaluation of cardiovascular devices using a mock circulation loop (MCL) is essential prior to in vivo or clinical trials. MCLs often consist of only a systemic circulation with no autoregulatory responses and limited validation. This study aimed to develop, and validate against human data, an advanced MCL with systemic, pulmonary, cerebral, and coronary circulations with autoregulatory responses. The biventricular MCL was constructed with pneumatically controlled hydraulic circulations with Starling responsive ventricles and autoregulatory cerebral and coronary circulations. Hemodynamic repeatability was assessed and complemented by validation using impedance cardiography data from 50 healthy humans. The MCL successfully simulated patient scenarios including rest, exercise, and left heart failure with and without cardiovascular device support. End-systolic pressure-volume relationships for respective healthy and heart failure conditions had slopes of 1.27 and 0.54 mm Hg mL
Publisher: SAGE Publications
Date: 18-05-2016
Abstract: The high velocity jet from aortic arterial cannulae used during cardiopulmonary bypass potentially causes a “sandblasting” injury to the aorta, increasing the possibility of embolisation of atheromatous plaque. We investigated a range of commonly available dispersion and non-dispersion cannulae, using particle image velocimetry. The maximum velocity of the exit jet was assessed 20 and 40 mm from the cannula tip at flow rates of 3 and 5 L/min. The dispersion cannulae had lower maximum velocities compared to the non-dispersion cannulae. Dispersion cannulae had fan-shaped exit profiles and maximum velocities ranged from 0.63 to 1.52 m/s when measured at 20 mm and 5 L/min. Non-dispersion cannulae had maximum velocities ranging from 1.52 to 3.06 m/s at 20 mm and 5 L/min, with corresponding narrow velocity profiles. This study highlights the importance of understanding the hydrodynamic performance of these cannulae as it may help in selecting the most appropriate cannula to minimize the risk of thromboembolic events or aortic injury.
Publisher: Elsevier BV
Date: 10-2011
Publisher: IEEE
Date: 07-2019
Publisher: Informa UK Limited
Date: 2009
DOI: 10.1080/03091900802184072
Abstract: Mock circulation loops are used to evaluate the performance of cardiac assist devices prior to animal and clinical testing. A compressible, translucent silicone ventricle chamber that mimics the exact size, shape and motion of a failing heart is desired to assist in flow visualization studies around inflow cannulae during VAD support. The aim of this study was therefore to design and construct a naturally shaped flexible left ventricle and evaluate its performance in a mock circulation loop. The ventricle shape was constructed by the use of CT images taken from a patient experiencing cardiomyopathic heart failure and used to create a 3D image and subsequent mould to produce a silicone ventricle. Different cardiac conditions were successfully simulated to validate the ventricle performance, including rest, left heart failure and VAD support.
Publisher: Ovid Technologies (Wolters Kluwer Health)
Date: 03-2000
Publisher: IEEE
Date: 07-2018
Publisher: Springer Science and Business Media LLC
Date: 30-05-2009
Publisher: Springer Science and Business Media LLC
Date: 25-03-2021
Publisher: Elsevier BV
Date: 12-2020
Publisher: SAGE Publications
Date: 12-1998
DOI: 10.1177/00220345980770120601
Abstract: Many factors influence the extent and rate at which enamel wears. Clinical studies in humans are limited by difficulties in the accurate quantification of intra-oral wear and by a lack of control over the oral environment. The purpose of this study was to determine the wear characteristics of human dental enamel under controlled experimental conditions. An electro-mechanical tooth wear machine, in which opposing enamel surfaces of sectioned, extracted teeth were worn under various conditions, was used to simulate tooth grinding or bruxism. Enamel surface wear was quantified by weight to an accuracy of 0.1 mg, with water uptake and loss controlled. The variables considered included the structure and hardness of enamel, facet area, duration of tooth contact, relative speed of opposing surfaces, temperature, load, pH, and the nature of the lubricant. Enamel wear under non-lubricated conditions increased with increasing load over the range of 1.7 to 16.2 kg. The addition of a liquid lubricant (pH = 7) reduced enamel wear up to 6.7 kg, but when the load increased above this threshold, the rate of wear increased dramatically. With the viscosity of the lubricant constant and pH = 3, the rate of wear was further reduced to less than 10% of the non-lubricated rate at 9.95 kg, after which the rate again increased substantially. Under more extreme conditions (pH = 1.2, simulating gastric acids), the wear was excessive under all experimental loads. When saliva was used as a lubricant, the amount of wear was relatively low at 9.95 kg, but rapid wear occurred at 14.2 kg and above. These results indicate that under non-lubricated conditions, enamel wear remains low at high loads due to the dry-lubricating capabilities of fine enamel powder. Under lubricated conditions, low loads with an acidic lubricant lead to little enamel wear, whereas very low pH results in a high rate of wear under all loads.
Publisher: Ovid Technologies (Wolters Kluwer Health)
Date: 03-2000
Publisher: Elsevier BV
Date: 10-2020
Publisher: Wiley
Date: 06-2000
DOI: 10.1046/J.1525-1594.2000.06584.X
Abstract: The VentrAssist pump has no shaft or seal, and the device is unique in design because the rotor is suspended passively by hydrodynamic forces, and urging is accomplished by an integrated direct current motor rotor that also acts as the pump impeller. This device has led to many challenges in its fluidic design, namely large flow-blockage from impeller blades, low stiffness of bearings with concomitant impeller displacement under pulsatile load conditions, and very small running clearances. Low specific speed and radial blade off-flow were selected in order to minimize the hemolysis. Pulsatile and steady-flow tests show the impeller is stable under normal operating conditions. Computational fluid dynamics (CFD) has been used to optimize flow paths and reduce net axial force imbalance to acceptably small values. The latest design of the pump achieved a system efficiency of 18% (in 30% hematocrit of red blood cells suspended in phosphate-buffered saline), and efficiency was optimized over the range of operating conditions. Parameters critical to improving pump efficiency were investigated.
Publisher: Wiley
Date: 08-2000
DOI: 10.1046/J.1525-1594.2000.06586.X
Abstract: Flow rate and pressure difference (or head) are key variables needed in the control of implantable rotary blood pumps. However, use of flow and/or pressure probes can decrease reliability and increase system power consumption and expense. For a given fluid viscosity, the flow state is determined by any 2 of the 4 pump variables: Flow, pressure difference, speed, and motor input power can be used. Thus, if viscosity is known or if its influence is sufficiently small, flow rate and pressure difference can be estimated from the motor speed and motor input power. For the VentrAssist centrifugal blood pump, which uses a hydrodynamic bearing, sensorless flow and pressure head estimation accuracy of 2 of our impeller designs were compared for a viscosity range of 1.2 to 4.5 mPas. This showed impeller design optimization can improve estimation accuracy. We also compared estimation accuracy using 2 blood analogues used in vitro, aqueous glycerol and red blood cells suspended in Haemaccel. The nature of the blood analogue and not only the viscosity of the fluid seems to influence estimation accuracy in our pump.
Publisher: Wiley
Date: 29-01-2013
DOI: 10.1111/J.1525-1594.2012.01561.X
Abstract: Cell exclusion is the phenomenon whereby the hematocrit and viscosity of blood decrease in areas of high stress. While this is well known in naturally occurring Poiseuille flow in the human body, it has never previously been shown in Couette flow, which occurs in implantable devices including blood pumps. The high-shear stresses that occur in the gap between the boundaries in Couette flow are known to cause hemolysis in erythrocytes. We propose to mitigate this damage by initiating cell exclusion through the use of a spiral-groove bearing (SGB) that will provide escape routes by which the cells may separate themselves from the plasma and the high stresses in the gap. The force between two bearings (one being the SGB) in Couette flow was measured. Stained erythrocytes, along with silver spheres of similar diameter to erythrocytes, were visualized across a transparent SGB at various gap heights. A reduction in the force across the bearing for human blood, compared with fluids of comparable viscosity, was found. This indicates a reduction in the viscosity of the fluid across the bearing due to a lowered hematocrit because of cell exclusion. The corresponding images clearly show both cells and spheres being excluded from the gap by entering the grooves. This is the first time the phenomenon of cell exclusion has been shown in Couette flow. It not only furthers our understanding of how blood responds to different flows but could also lead to improvements in the future design of medical devices.
Publisher: Wiley
Date: 08-01-2016
DOI: 10.1111/AOR.12654
Abstract: Preventing ventricular suction and venous congestion through balancing flow rates and circulatory volumes with dual rotary ventricular assist devices (VADs) configured for biventricular support is clinically challenging due to their low preload and high afterload sensitivities relative to the natural heart. This study presents the in vivo evaluation of several physiological control systems, which aim to prevent ventricular suction and venous congestion. The control systems included a sensor-based, master/slave (MS) controller that altered left and right VAD speed based on pressure and flow a sensor-less compliant inflow cannula (IC), which altered inlet resistance and, therefore, pump flow based on preload a sensor-less compliant outflow cannula (OC) on the right VAD, which altered outlet resistance and thus pump flow based on afterload and a combined controller, which incorporated the MS controller, compliant IC, and compliant OC. Each control system was evaluated in vivo under step increases in systemic (SVR ∼1400-2400 dyne/s/cm(5) ) and pulmonary (PVR ∼200-1000 dyne/s/cm(5) ) vascular resistances in four sheep supported by dual rotary VADs in a biventricular assist configuration. Constant speed support was also evaluated for comparison and resulted in suction events during all resistance increases and pulmonary congestion during SVR increases. The MS controller reduced suction events and prevented congestion through an initial sharp reduction in pump flow followed by a gradual return to baseline (5.0 L/min). The compliant IC prevented suction events however, reduced pump flows and pulmonary congestion were noted during the SVR increase. The compliant OC maintained pump flow close to baseline (5.0 L/min) and prevented suction and congestion during PVR increases. The combined controller responded similarly to the MS controller to prevent suction and congestion events in all cases while providing a backup system in the event of single controller failure.
Publisher: Wiley
Date: 09-07-2015
DOI: 10.1111/AOR.12338
Abstract: Biventricular support with dual rotary ventricular assist devices (VADs) has been implemented clinically with restriction of the right VAD (RVAD) outflow cannula to artificially increase afterload and, therefore, operate within recommended design speed ranges. However, the low preload and high afterload sensitivity of these devices increase the susceptibility of suction events. Active control systems are prone to sensor drift or inaccurate inferred (sensor-less) data, therefore an alternative solution may be of benefit. This study presents the in vitro evaluation of a compliant outflow cannula designed to passively decrease the afterload sensitivity of rotary RVADs and minimize left-sided suction events. A one-way fluid-structure interaction model was initially used to produce a design with suitable flow dynamics and radial deformation. The resultant geometry was cast with different initial cross-sectional restrictions and concentrations of a softening diluent before evaluation in a mock circulation loop. Pulmonary vascular resistance (PVR) was increased from 50 dyne s/cm(5) until left-sided suction events occurred with each compliant cannula and a rigid, 4.5 mm diameter outflow cannula for comparison. Early suction events (PVR ∼ 300 dyne s/cm(5) ) were observed with the rigid outflow cannula. Addition of the compliant section with an initial 3 mm diameter restriction and 10% diluent expanded the outflow restriction as PVR increased, thus increasing RVAD flow rate and preventing left-sided suction events at PVR levels beyond 1000 dyne s/cm(5) . Therefore, the compliant, restricted outflow cannula provided a passive control system to assist in the prevention of suction events with rotary biventricular support while maintaining pump speeds within normal ranges of operation.
Publisher: Institute of Electrical and Electronics Engineers (IEEE)
Date: 05-2021
Publisher: American Astronomical Society
Date: 10-08-1999
DOI: 10.1086/307529
Publisher: Wiley
Date: 03-05-2018
DOI: 10.1111/AOR.13142
Abstract: Although rotary blood pumps (RBPs) sustain life, blood exposure to continuous supra-physiological shear stress induces adverse effects (e.g., thromboembolism) thus, pulsatile flow in RBPs represents a potential solution. The present study introduced pulsatile flow to the HeartWare HVAD using a custom-built controller and compared hemocompatibility biomarkers (i.e., platelet aggregation, concentrations for ADAMTS13, von Willebrand factor (vWf), and free-hemoglobin in plasma (pfHb), red blood cell (RBC) deformability, and RBC-nitric oxide synthase (NOS) activity) between continuous and pulsatile flow in a blood circulation loop over 5 h. The HeartWare HVAD was operated using a custom-built controller, at continuous speed (3282 rev/min) or in a pulsatile mode (mean speed = 3273 rev/min, litude = 430 rev/min, frequency = 1 Hz) to generate a blood flow rate of 5.0 L/min, HVAD differential pressure of 90 mm Hg for continuous flow and 92 mm Hg for pulsatile flow, and systolic and diastolic pressures of 121/80 mm Hg. For both flow regimes, the current study found (i) ADP- and collagen-induced platelet aggregation, and ADAMTS13 concentration significantly decreased after 5 h (P < 0.01 P < 0.05), (ii) ristocetin-induced platelet aggregation significantly increased after 45 min (P < 0.05), (iii) vWf concentration did not significantly differ at any time point, (iv) pfHb significantly increased after 5 h (P < 0.01), (v) RBC deformability improved during the continuous flow regime (P < 0.05) but not during pulsatile flow, and (vi) RBC-NOS activity significantly increased during continuous flow (15 min), and pulsatile flow (5 h P < 0.05). The current study demonstrated: (i) speed modulation does not improve hemocompatibility of the HeartWare HVAD based on no observable differences being detected for routine biomarkers, and (ii) the time-course for increased RBC-NOS activity observed during continuous flow may have improved RBC deformability.
Publisher: Wiley
Date: 15-08-2020
DOI: 10.1111/AOR.13783
Publisher: Springer Science and Business Media LLC
Date: 02-2016
DOI: 10.1007/S10439-016-1552-3
Abstract: Rotary left ventricular assist devices (LVADs) show weaker response to preload and greater response to afterload than the native heart. This may lead to ventricular suction or pulmonary congestion, which can be deleterious to the patient's recovery. A physiological control system which optimizes responsiveness of LVADs may reduce adverse events. This study compared eight physiological control systems for LVAD support against constant speed mode. Pulmonary (PVR) and systemic (SVR) vascular resistance changes, a passive postural change and exercise were simulated in a mock circulation loop to evaluate the controller's ability to prevent suction and congestion and to increase exercise capacity. Three active and one passive control systems prevented ventricular suction at high PVR (500 dyne s cm(-5)) and low SVR (600 dyne s cm(-5)) by decreasing LVAD speed (by 200-515 rpm) and by increasing LVAD inflow cannula resistance (up to 1000 dyne s cm(-5)) respectively. These controllers increased LVAD preload sensitivity (to 0.196-2.415 L min(-1) mmHg(-1)) compared to the other control systems and constant speed mode (0.039-0.069 L min(-1) mmHg(-1)). The same three active controllers increased pump speed (600-800 rpm) and thus LVAD flow by 4.5 L min(-1) during exercise which increased exercise capacity. Physiological control systems that prevent adverse events and/or increase exercise capacity may help improve LVAD patient conditions.
Publisher: Ovid Technologies (Wolters Kluwer Health)
Date: 07-2015
Publisher: Mary Ann Liebert Inc
Date: 06-2021
Publisher: Elsevier BV
Date: 11-2019
Publisher: Ovid Technologies (Wolters Kluwer Health)
Date: 15-07-2020
Publisher: Springer Science and Business Media LLC
Date: 18-08-2016
DOI: 10.1007/S10439-015-1425-1
Abstract: The low preload and high afterload sensitivities of rotary ventricular assist devices (VADs) may cause ventricular suction events or venous congestion. This is particularly problematic with rotary biventricular support (BiVAD), where the Starling response is diminished in both ventricles. Therefore, VADs may benefit from physiological control systems to prevent adverse events. This study compares active, passive and combined physiological controllers for rotary BiVAD support with constant speed mode. Systemic (SVR) and pulmonary (PVR) vascular resistance changes and exercise were simulated in a mock circulation loop to evaluate the capacity of each controller to prevent suction and congestion and increase exercise capacity. All controllers prevented suction and congestion at high levels of PVR (900 dynes s cm(-5)) and SVR (3000 dynes s cm(-5)), however these events occurred in constant speed mode. The controllers increased preload sensitivity (0.198-0.34 L min(-1) mmHg(-1)) and reduced afterload sensitivity (0.0001-0.008 L min(-1) mmHg(-1)) of the VADs when compared to constant speed mode (0.091 and 0.072 L min(-1) mmHg(-1) respectively). The active controller increased pump speeds (400-800 rpm) and pump flow by 2.8 L min(-1) during exercise, thus increasing exercise capacity. By reducing suction and congestion and by increasing exercise capacity, the control systems presented in this study may help increase quality of life of VAD patients.
Publisher: Springer Science and Business Media LLC
Date: 07-1993
DOI: 10.1007/BF02446661
Publisher: IEEE
Date: 26-11-2020
Publisher: Elsevier BV
Date: 04-2020
Publisher: Wiley
Date: 06-2000
DOI: 10.1046/J.1525-1594.2000.06600.X
Abstract: The ability of the VentrAssist blood pump to perform at its optimum design point is determined by a number of factors such as geometry of the pump, surface roughness, and fluid properties. Once the fluid properties are known, the performance characteristics of the pump can be optimized for that fluid. It is important to understand the effects of dynamic viscosity mu (called simply viscosity hereafter) on the performance characteristics and stability of the pump. The performance envelope of the pump and the needs of the patient must be matched. The VentrAssist pump has no shaft, seals, or fixed bearings and relies on the fluid-dynamic forces to maintain its effective performance. A number of different fluids have been tested to determine the effects of viscosity and density on pump performance. These include aqueous glycerol, red blood cells (RBCs) suspended in phosphate buffered saline solution (PBS), and Haemaccel. The effects of viscosity on the bearing stiffness, stage efficiency, and the pressure-flow rate (HQ) are characterized. The experimental results show a slight increase in the pressure rise across the pump shown as a positive upward shift of the H-Q curves with a decrease in viscosity however, this is relatively small. A paradox in system efficiency exists: for a given fluid asymptotic viscosity, the system efficiency (product of magnetic and stage efficiency) using Haemaccel or PBS is greater than for the same viscosity of aqueous glycerol.
Publisher: Springer Science and Business Media LLC
Date: 03-1988
DOI: 10.1007/BF02442261
Abstract: Fluid imbalance can arise due to hypovolemia, normovolemia with maldistribution of fluid, and hypervolemia. Trauma is among the most frequent causes of hypovolemia, with its often profuse attendant blood loss. Another common cause is dehydration, which primarily entails loss of plasma rather than whole blood. The consequences of hypovolemia include reduction in circulating blood volume, lower venous return and, in profound cases, arterial hypotension. Myocardial failure may result from increased myocardial oxygen demand in conjunction with reduced tissue perfusion. Finally, anaerobic metabolism due to reduced perfusion may produce acidosis and, together with myocardial dysfunction, precipitate multi-organ failure. The splanchnic organs are particularly susceptible to the deleterious effects of hypotension and hypovolemic shock, and these effects, depending upon their duration and severity, may be irreversible despite restoration of normovolemia by fluid administration. Patient monitoring in the intensive care unit typically relies upon central venous pressure devices, whereas the primary focus in the operating theater is blood volume deficit estimated from suction devices. However, estimates of intraoperative blood loss can be inaccurate, potentially leading to inappropriate fluid management. Normovolemia with maldistribution of fluid can be encountered in shock-specific microcirculatory disorders secondary to hypovolemia, as well as pain and stress. Consequent vasoconstriction and reduced tissue driving pressure, as well as leukocyte and platelet adhesion, and liberation of humoral and cellular mediators, may impair or abolish blood flow in certain areas. The localized perfusion deficit may contribute to multi-organ failure. Choice of resuscitation fluid may be important in this context, since some evidence suggests that at least certain colloids might be helpful in diminishing post-ischemic microvascular leukocyte adherence. Excessive volume administration may lead to fluid overload and associated impairment of pulmonary function. However, entry of fluid into the lungs may also be facilitated by increased vascular permeability in certain pathologic conditions, especially sepsis and endotoxemia, even in the absence of substantially rising hydrostatic pressure. Another condition associated with elevated vascular permeability is systemic capillary leak syndrome. The chief goal of fluid management, based upon current understanding of the pathophysiology of fluid imbalance, should be to ensure adequate oxygen delivery by optimizing blood oxygenation, perfusion pressure, and circulating volume.
Publisher: Elsevier BV
Date: 2022
Publisher: Wiley
Date: 20-10-2019
DOI: 10.1111/AOR.13570
Abstract: Due to improved durability and survival rates, rotary blood pumps (RBPs) are the preferred left ventricular assist device when compared to volume displacement pumps. However, when operated at constant speed, RBPs lack a volume balancing mechanism which may result in left ventricular suction and suboptimal ventricular unloading. Starling-like controllers have previously been developed to balance circulatory volumes however, they do not consider ventricular workload as a feedback and may have limited sensitivity to adjust RBP workload when ventricular function deteriorates or improves. To address this, we aimed to develop a Starling-like total work controller (SL-TWC) that matched the energy output of a healthy heart by adjusting RBP hydraulic work based on measured left ventricular stroke work and ventricular preload. In a mock circulatory loop, the SL-TWC was evaluated using a HeartWare HVAD in a range of simulated patient conditions. These conditions included changes in systemic hypertension and hypotension, pulmonary hypertension, blood circulatory volume, exercise, and improvement and deterioration of ventricular function by increasing and decreasing ventricular contractility. The SL-TWC was compared to constant speed control where RBP speed was set to restore cardiac output to 5.0 L/min at rest. Left ventricular suction occurred with constant speed control during pulmonary hypertension but was prevented with the SL-TWC. During simulated exercise, the SL-TWC demonstrated reduced LVSW (0.51 J) and greater RBP flow (9.2 L/min) compared to constant speed control (LVSW: 0.74 J and RBP flow: 6.4 L/min). In instances of increased ventricular contractility, the SL-TWC reduced RBP hydraulic work while maintaining cardiac output similar to the rest condition. In comparison, constant speed overworked and increased cardiac output. The SL-TWC balanced circulatory volumes by mimicking the Starling mechanism, while also considering changes in ventricular workload. Compared to constant speed control, the SL-TWC may reduce complications associated with volume imbalances, adapt to changes in ventricular function and improve patient quality of life.
Publisher: Trans Tech Publications, Ltd.
Date: 08-2011
DOI: 10.4028/WWW.SCIENTIFIC.NET/AMR.314-316.1889
Abstract: Distortion is one type of defect in the weld, which is troublesome for some reasons, especially in thin plate welding. Distortion was found in fibre laser welding processing for 0.7mm thickness Ti6Al4V plate. The purpose of this paper is to understand and evaluate the effect of distortion on stress level by FEA and tensile test. A group of 0.7mm Ti6Al4V plates welded using continuous wave fibre laser. FEA models were established for fibre laser welded Ti6Al4V in abaqus 6.7.
Publisher: Springer Science and Business Media LLC
Date: 16-06-2020
Publisher: Wiley
Date: 11-04-2019
DOI: 10.1111/AOR.13454
Abstract: The high cost of ventricular assist devices results in poor cost-effectiveness when used as a short-term bridging solution, thus a low-cost alternative is desirable. The present study aimed to develop an intraventricular balloon pump (IVBP) for short-term circulatory support, and to evaluate the effect of balloon actuation timing on the degree of cardiac support provided to a simulated in vitro severe heart failure (SHF) patient. A silicone IVBP was designed to avoid contact with internal left ventricular (LV) features (ie, papillary muscles, chordae, aortic, and mitral valves) based on LV computed tomography data of 10 SHF patients with dilated cardiomyopathy. The hemodynamic effects of varying balloon inflation and deflation timing parameters (inflation duty [D] and end-inflation point [σ]) were evaluated in a purpose-built systemic mock circulatory loop. Three IVBP actuation timing categories were defined: co-, transitional, and counterpulsation. Compared to the SHF baseline, co-pulsation increased aortic flow from 3.5 to 5.2 L/min, mean arterial pressure from 72.1 to 94.8 mmHg and ejection fraction from 14.4% to 21.5%, while mean left atrial pressure decreased from 14.6 to 10 mmHg. Transitional and counterpulsation resulted in a double ventricular pulse and extended the duration of increased ventricular pressure, potentially impeding diastolic filling and coronary perfusion. This in vitro study showed the IVBP could restore the hemodynamic balance of a simulated SHF patient with dilated cardiomyopathy to healthy levels.
Location: United Kingdom of Great Britain and Northern Ireland
Location: United Kingdom of Great Britain and Northern Ireland
Location: United Kingdom of Great Britain and Northern Ireland
Start Date: 06-2003
End Date: 12-2006
Amount: $69,099.00
Funder: Australian Research Council