ORCID Profile
0000-0002-6402-8315
Current Organisations
University of Granada
,
Max-Planck-Institut für Biochemie
Does something not look right? The information on this page has been harvested from data sources that may not be up to date. We continue to work with information providers to improve coverage and quality. To report an issue, use the Feedback Form.
Publisher: Springer Science and Business Media LLC
Date: 06-2018
DOI: 10.1038/S41586-018-0236-6
Abstract: The class A adenosine A
Publisher: Elsevier BV
Date: 11-2010
DOI: 10.1016/J.JSB.2010.02.011
Abstract: A principal limitation of cryo-transmission electron microscopy performed on cells or tissues is the accessible specimen thickness. This is exacerbated in tomography applications, where the aspect ratio (and thus the apparent specimen thickness) changes considerably during specimen tilting. Cryo-ultramicrotomy is the most obvious way of dealing with this problem however, frozen-hydrated sections suffer from potentially inconsistent compression that cannot be corrected with certainty, and furthermore, yields of sections that satisfy all of the conditions necessary for tomographic imaging are poor. An alternative approach that avoids mechanical deformations is the use of focused ion beam (FIB) instrumentation, where thinning of the frozen-hydrated specimen occurs through the process of sputtering with heavy ions, typically gallium. Here, we use correlative cryo-fluorescence microscopy to navigate large cellular volumes and to localize specific cellular targets. We show that the selected targets in frozen-hydrated specimens can be accessed directly by focused ion beam milling. We also introduce a novel cryo-planing procedure as a method that could facilitate thinning of large areas of vitreous ice prior to cryo-fluorescence, FIB thinning, and cryo-electron tomography.
Publisher: Oxford University Press (OUP)
Date: 07-2009
DOI: 10.1017/S1431927609096299
Abstract: Extended abstract of a paper presented at Microscopy and Microanalysis 2009 in Richmond, Virginia, USA, July 26 – July 30, 2009
Publisher: Cold Spring Harbor Laboratory
Date: 20-05-2021
DOI: 10.1101/2021.05.19.444745
Abstract: Lamella micromachining by focused ion beam milling at cryogenic temperature (cryo-FIB) has matured into a preparation method widely used for cellular cryo-electron tomography. Due to the limited ablation rates of low Ga + ion beam currents required to maintain the structural integrity of vitreous specimens, current preparation protocols are time-consuming and labor intensive. The improved stability of new generation cryo-FIB instruments now enables automated operations. Here, we present an open-source software tool, SerialFIB, for creating automated and customizable cryo-FIB preparation protocols. The software encompasses a graphical user interface for easy execution of routine lamellae preparations, a scripting module compatible with available python packages, and interfaces with 3-dimensional correlative light and electron microscopy (CLEM) tools. The software enables the streamlining of advanced cryo-FIB protocols such as multi-modal imaging, CLEM guided preparation and in situ lamella lift-out procedures. Our software therefore provides a foundation for further development of advanced cryogenic imaging and s le preparation protocols.
Publisher: Oxford University Press (OUP)
Date: 08-2005
Publisher: Proceedings of the National Academy of Sciences
Date: 11-03-2008
Abstract: The cell walls of mycobacteria form an exceptional permeability barrier, and they are essential for virulence. They contain extractable lipids and long-chain mycolic acids that are covalently linked to peptidoglycan via an arabinogalactan network. The lipids were thought to form an asymmetrical bilayer of considerable thickness, but this could never be proven directly by microscopy or other means. Cryo-electron tomography of unperturbed or detergent-treated cells of Mycobacterium smegmatis embedded in vitreous ice now reveals the native organization of the cell envelope and its delineation into several distinct layers. The 3D data and the investigation of ultrathin frozen-hydrated cryosections of M. smegmatis , Myobacterium bovis bacillus Calmette–Guérin, and Corynebacterium glutamicum identified the outermost layer as a morphologically symmetrical lipid bilayer. The structure of the mycobacterial outer membrane necessitates considerable revision of the current view of its architecture. Conceivable models are proposed and discussed. These results are crucial for the investigation and understanding of transport processes across the mycobacterial cell wall, and they are of particular medical relevance in the case of pathogenic mycobacteria.
Publisher: Springer Science and Business Media LLC
Date: 09-2018
Publisher: eLife Sciences Publications, Ltd
Date: 24-12-2021
DOI: 10.7554/ELIFE.70506
Abstract: Lamella micromachining by focused ion beam milling at cryogenic temperature (cryo-FIB) has matured into a preparation method widely used for cellular cryo-electron tomography. Due to the limited ablation rates of low Ga + ion beam currents required to maintain the structural integrity of vitreous specimens, common preparation protocols are time-consuming and labor intensive. The improved stability of new-generation cryo-FIB instruments now enables automated operations. Here, we present an open-source software tool, SerialFIB, for creating automated and customizable cryo-FIB preparation protocols. The software encompasses a graphical user interface for easy execution of routine lamellae preparations, a scripting module compatible with available Python packages, and interfaces with three-dimensional correlative light and electron microscopy (CLEM) tools. SerialFIB enables the streamlining of advanced cryo-FIB protocols such as multi-modal imaging, CLEM-guided lamella preparation and in situ lamella lift-out procedures. Our software therefore provides a foundation for further development of advanced cryogenic imaging and s le preparation protocols.
Publisher: eLife Sciences Publications, Ltd
Date: 30-11-2021
Publisher: Elsevier BV
Date: 02-2009
DOI: 10.1016/J.COPBIO.2009.03.008
Abstract: In cell biology, visual techniques such as light and electron microscopy provide the most intuitive means by which to study structure and function however, no single microscopy technique is capable of providing all of the desired information. As a consequence, many separate techniques have evolved, each with unique capabilities. The most informative approaches are global in the sense that they take advantage of multiple imaging modalities spanning a range of spatial scales and frequencies, preferably encompassing preservation of the hydrated nature of the cell. Correlative microscopy utilizes complementary visual techniques that allow the experimenter to capture significant proportions of a population of cells, to identify features of interest, and to then capture high-resolution snapshots that represent bona fide cellular events.
Publisher: Elsevier BV
Date: 2018
DOI: 10.1016/J.NUMECD.2017.10.004
Abstract: Inflammation may influence the cardio-metabolic profile which relates with the risk of chronic diseases. This study aimed to assess the inflammatory status by metabolic health (MH)/body mass index (BMI) category and to assess how inflammatory markers can predict the cardio-metabolic profile in European adolescents, considering BMI. A total of 659 adolescents (295 boys) from a cross-sectional European study were included. Adolescents were classified by metabolic health based on age- and sex-specific cut-off points for glucose, blood pressure, triglycerides, high density cholesterol and BMI. C-reactive protein (CRP), tumor necrosis factor alpha (TNF-α), interleukin (IL-6), complement factors (C3, C4) and cell adhesion molecules were assessed. Metabolically abnormal (MA) adolescents had higher values of C3 (p < 0.001) and C4 (p = 0.032) compared to those metabolically healthy (MHy). C3 concentrations significantly increased with the deterioration of the metabolic health and BMI (p < 0.001). Adolescents with higher values of CRP had higher probability of being in the overweight/obese-MH group than those allocated in other categories. Finally, high C3 and C4 concentrations increased the probability of having an unfavorable metabolic/BMI status. Metabolic/BMI status and inflammatory biomarkers are associated, being the CRP, C3 and C4 the most related inflammatory markers with this condition. C3 and C4 were associated with the cardio-metabolic health consistently.
Publisher: Elsevier BV
Date: 02-2016
Location: United States of America
No related grants have been discovered for Juergen Plitzko.