ORCID Profile
0000-0002-9264-3243
Current Organisation
Massachusetts General Hospital
Does something not look right? The information on this page has been harvested from data sources that may not be up to date. We continue to work with information providers to improve coverage and quality. To report an issue, use the Feedback Form.
Publisher: Ovid Technologies (Wolters Kluwer Health)
Date: 28-09-2021
DOI: 10.1161/CIRCULATIONAHA.120.046791
Abstract: Ischemia with no obstructive coronary artery disease (INOCA) is common and has an adverse prognosis. We set out to describe the natural history of symptoms and ischemia in INOCA. CIAO-ISCHEMIA (Changes in Ischemia and Angina over One Year in ISCHEMIA Trial Screen Failures With INOCA) was an international cohort study conducted from 2014 to 2019 involving angina assessments (Seattle Angina Questionnaire) and stress echocardiograms 1 year apart. This was an ancillary study that included patients with a history of angina who were not randomly assigned in the ISCHEMIA trial. Stress-induced wall motion abnormalities were determined by an echocardiographic core laboratory blinded to symptoms, coronary artery disease status, and test timing. Medical therapy was at the discretion of treating physicians. The primary outcome was the correlation between the changes in the Seattle Angina Questionnaire angina frequency score and changes in echocardiographic ischemia. We also analyzed predictors of 1-year changes in both angina and ischemia, and we compared CIAO participants with ISCHEMIA participants with obstructive coronary artery disease who had stress echocardiography before enrollment, as CIAO participants did. INOCA participants in CIAO were more often female (66% of 208 versus 26% of 865 ISCHEMIA participants with obstructive coronary artery disease, P .001), but the magnitude of ischemia was similar (median 4 ischemic segments [interquartile range, 3–5] both groups). Ischemia and angina were not significantly correlated at enrollment in CIAO ( P =0.46) or ISCHEMIA stress echocardiography participants ( P =0.35). At 1 year, the stress echocardiogram was normal in half of CIAO participants, and 23% had moderate or severe ischemia (≥3 ischemic segments). Angina improved in 43% and worsened in 14%. Change in ischemia over 1 year was not significantly correlated with change in angina (ρ=0.029). Improvement in ischemia and angina were common in INOCA but not correlated. Our INOCA cohort had a degree of inducible wall motion abnormalities similar to concurrently enrolled ISCHEMIA participants with obstructive coronary artery disease. Our results highlight the complex nature of INOCA pathophysiology and the multifactorial nature of angina. URL: www.clinicaltrials.gov . Unique identifier: NCT02347215.
Publisher: Massachusetts Medical Society
Date: 26-08-1999
Publisher: Elsevier BV
Date: 05-2006
Publisher: Elsevier BV
Date: 12-2002
Publisher: Springer Science and Business Media LLC
Date: 07-08-2023
Publisher: Elsevier BV
Date: 06-2014
Publisher: Wiley
Date: 11-2003
DOI: 10.1111/J.0742-2822.2003.02173.X
Abstract: Transcatheter techniques have evolved as alternatives to surgical closure of interatrial communications due to its less invasive nature and low morbidity. The technique may be limited by the inability to deploy the device and, thus, may be complicated by significant residual shunting. Mobile or redundant septal tissue has been implicated as a possible cause of unsuccessful closure. To determine if atrial septal hypermobility precludes successful transcatheter device closure of interatrial communications, 69 patients (mean age 46.4 +/- 17.5 years [male:female ratio 34:35]) with periprocedural transesophageal echocardiograms were reviewed. Septal excursion was defined as the maximal transit of the interatrial septum between either side of the plane connecting the superior and inferior attachment points. Unsuccessful closure was defined as subsequent cardiac surgery to close the defect, inability to deploy the device, recurrent attempts at closure, device malalignment, residual shunting greater than mild in degree on follow-up transthoracic study, and procedural complications. Reasons for closure were the following: embolic events (n = 48) platypnea/orthodeoxia (n = 15) atrial septal defect with right ventricular dilatation and paroxysmal atrial tachycardia (n = 2) atrial septal defect (n = 3) and prophylactic patent foramen ovale closure in a scuba er (n = 1). Successful closure occurred in 76% of patients (n = 53). Compared with those patients with successful transcatheter closure, the mean septal excursion in patients with failed closure was 0.66 +/- 0.56 cm versus 0.76 +/- 0.47 cm (P = not significant [NS]). Our results do not support the concern that exaggerated septal mobility compromises successful device closure of interatrial communications.
Publisher: Oxford University Press (OUP)
Date: 2009
DOI: 10.1093/EJECHOCARD/JEN321
Abstract: To determine if perfusion stress echocardiography (PSE) with Imagify (perflubutane polymer microspheres) is comparable to stress perfusion imaging using (99m)Tc single photon emission computed tomography (SPECT) for coronary artery disease (CAD) detection. PSE is a novel technique for evaluating myocardial perfusion. RAMP (real-time assessment of myocardial perfusion)-1 and -2 were international, Phase 3 trials that evaluated the ability of PSE with Imagify, to detect CAD. Chronic, stable, chest pain patients (n=662) underwent Imagify PSE and gated SPECT imaging at rest and during dipyridamole stress. Independent blinded cardiologists [three PSE readers per trial, and four SPECT readers (one for RAMP-1, three for RAMP-2)] interpreted images. CAD was defined by quantitative coronary angiography or 90-day outcome with clinical review. Accuracy, sensitivity, and specificity were evaluated using non-inferiority analysis (one-sided alpha=0.025) compared with SPECT. SPECT results for RAMP-1 and -2 were: accuracy (70%, 67%), sensitivity (78%, 61%), and specificity (64%, 76%). Accuracy of all six PSE readers was non-inferior to SPECT (66-71%, P<or=0.004). Four demonstrated non-inferior sensitivity (68-77%, P<or=0.002), three demonstrated non-inferior specificity (72-88%, P<or=0.013). Three PSE readers (RAMP-2) were superior for sensitivity. Two PSE readers (RAMP-1) were superior for specificity. Area under the multi-reader receiver operating characteristics curve (0.72) was equal for both modalities. Majority of adverse events followed dipyridamole dosing, and were mild, transient, and required no treatment. Imagify PSE was well-tolerated. Its diagnostic performance in chest pain patients is comparable with SPECT perfusion imaging.
Location: United States of America
No related grants have been discovered for Michael Picard.