Regulation Of Key Pathways Causing Peri-implant Bone Loss.
Funder
National Health and Medical Research Council
Funding Amount
$403,639.00
Summary
The failure of bone prostheses is becoming a major health problem in our aging population. Despite the impressive success of joint replacement surgery, a significant number of arthroplasties fail. It is now apparent that most implants fail due to bone loss around them which leads to loosening. This project aims to obtain a better understanding of the causes of implant failure and find ways to extend the life of these implants .
Determination Of Irradiation Dose Efficacy For Use In Impaction Grafting At Revision Joint Replacement
Funder
National Health and Medical Research Council
Funding Amount
$411,517.00
Summary
Primary hip replacement is a successful intervention for hip disease, but 10-15% of hip prostheses fail and require revision surgery within 10-15 years. At the time of revision, significant bone loss around the failed prosthesis is not uncommon. A bone reconstruction procedure, called impaction grafting, where donor bone is minced and placed in the areas of deficient bone before implanting the new prosthesis, has shown to give good results at more than ten years in some centres. A high incidence ....Primary hip replacement is a successful intervention for hip disease, but 10-15% of hip prostheses fail and require revision surgery within 10-15 years. At the time of revision, significant bone loss around the failed prosthesis is not uncommon. A bone reconstruction procedure, called impaction grafting, where donor bone is minced and placed in the areas of deficient bone before implanting the new prosthesis, has shown to give good results at more than ten years in some centres. A high incidence of early complications of this procedure have included loss of fixation within the bone. Fracture of the bone around prostheses has also reported in some centres. These events require more surgery, putting the patient at higher risk greater complications and longer rehabilitations. Recent improvements in surgical technique and donor bone preparation have improved results. A current debate questions whether the dose of irradiation can be reduced from 25 kGy, while maintaining sterility of allografts. The risk of bacterial contamination in allografts is low, and irradiation reduces the mechanical strength of the graft, contributing to complications when irradiated bone is used. The benefits of decontaminating the bone may be outweighed by the higher risk for failure due to poor bone quality and resulting prosthesis instability. We will use ISO standards to test the validity of radiation dose for sterilising bone ex vivo. In the absence of controlled human studies, our aim is also to compare the results of impaction grafting with non-irradiated bone versus bone irradiated at current doses used by Australian bone banks, and lower doses indicated by ex vivo testing. We will use a large animal model of revision hip replacement, with precise measures of prosthesis stability. The results of this study will guide clinical decisions regarding the efficacy of current bone graft preparation procedures and the use of irradiated bone in human hip replacement surgery.Read moreRead less
The Role Of Osteocytes In Particle Induced Osteolysis
Funder
National Health and Medical Research Council
Funding Amount
$457,196.00
Summary
Hip replacements often fail due to the loss of adjacent bone. Metal or polyethylene particles are produced as the prosthesis bearing surface wears but how do these particles lead to bone loss? Our work suggests involvement of osteocytes within the bone mineral, which are increasingly understood to drive bone physiology and pathology. We will explore the role of the osteocytes by examining their response to particles, which may identify a new target to prevent particle-induced bone loss.
The Risks And Benefits Of Contemporary Total Hip Replacement
Funder
National Health and Medical Research Council
Funding Amount
$493,530.00
Summary
The number of hip replacements undertaken in Australia is steadily increasing. The most common complications of hip replacements are dislocation and loosening due to bone loss around the implant, requiring complex and expensive revision surgery. This study will investigate the incidence of dislocation and, using a new diagnostic imaging technique, the incidence and amount of bone loss around a relatively new prosthetic material, the outcomes of which are not known despite its increasing use.
Maximum Acceptable Risk Of Complication In Total Knee Arthroplasty (MARKA) Study: Using Discreet Choice Experiments To Elicit Patient And Surgeon Perception Of Acceptable Risk In Total Knee Arthroplasty
Funder
National Health and Medical Research Council
Funding Amount
$465,199.00
Summary
Patient expectation is the strongest predictor of satisfaction following total knee replacement. Dissatisfaction with surgery is reported in approximately 1 in 5 patients undergoing knee replacement. Unrealistic patient expectations and uninformed perceptions of potential benefits, risks and limitations of surgery lead to dissatisfaction in many cases. This study will examine the “risk-benefit” preferences in patients and surgeons considering total knee replacement as a treatment option for end- ....Patient expectation is the strongest predictor of satisfaction following total knee replacement. Dissatisfaction with surgery is reported in approximately 1 in 5 patients undergoing knee replacement. Unrealistic patient expectations and uninformed perceptions of potential benefits, risks and limitations of surgery lead to dissatisfaction in many cases. This study will examine the “risk-benefit” preferences in patients and surgeons considering total knee replacement as a treatment option for end-stage osteoarthritis.Read moreRead less
A Randomised Controlled Trial Examining Stability Of New Types Of Highly Porous Surfaced Acetabular Components In Total Hip Replacement
Funder
National Health and Medical Research Council
Funding Amount
$216,490.00
Summary
Numbers of total hip replacements are steadily increasing. The most common complication of hip replacement is late implant loosening, which can be predicted by early migration. We will examine early migration of a trabecular metal acetabular cup without screws, compared to a titanium fibre metal acetabular cup fixed with screws. Ideally, an acetabular cup would achieve a level of initial stability by press-fit alone without screws, as screws increase the risk of bone loss around the prosthesis.
Impaired Bone Remodelling Leads To Failure Of Orthopaedic Prostheses
Funder
National Health and Medical Research Council
Funding Amount
$515,917.00
Summary
The failure of bone prostheses is becoming a major health problem. More than 26,000 hip, and an equal number of knee, replacements were performed in Australia in 2002 with the number increasing between 5%-10% each year for the previous 10 years. Disturbingly, the incidence of revision hip surgery in Australia is now more than 15%, meaning that, despite the impressive success of joint replacement surgery, a significant number of arthroplasties fail. It is becoming more common for young, active in ....The failure of bone prostheses is becoming a major health problem. More than 26,000 hip, and an equal number of knee, replacements were performed in Australia in 2002 with the number increasing between 5%-10% each year for the previous 10 years. Disturbingly, the incidence of revision hip surgery in Australia is now more than 15%, meaning that, despite the impressive success of joint replacement surgery, a significant number of arthroplasties fail. It is becoming more common for young, active individuals to receive joint replacement surgery to improve their quality of life. This, combined with increasing life expectancy, and the known higher rate of failure of joint replacements in younger patients, means that the morbidity of a failed replacement, and the mobidity and associated mortality of revision surgery, will become an increasingly important health issue, with a major impact upon health budgets. The overwhelming majority of hip and knee prostheses have metal or ceramic on polyethylene bearing surfaces. It is now apparent that most implants fail due to bone loss around them leading to loosening, and evidence is accumulating that polyethylene wear particles are a major contributing factor to this process. It is therefore vital that we obtain better understanding of the causes of implant failure in order to extend the life of these implants and this project is designed to do so.Read moreRead less
The Role Of Stem-progenitor Cells In Regeneration Of Mouse Endometrium.
Funder
National Health and Medical Research Council
Funding Amount
$311,938.00
Summary
The endometrium (lining of the uterus) undergoes breakdown and re-growth each month as part of the menstrual cycle. This restorative process is not well understood. For the first time stem cells have been identified within human endometrium that are likely to be responsible for its remarkable regeneration. The aim of this project is to identify stem cells within the mouse endometrium, to use as a model to understand how the endometrium restores each month after menstruation.