Radiostereometric Analysis Of The Effect Of A Large Articulation On Prosthetic Wear And Migration After Hip Replacement
Funder
National Health and Medical Research Council
Funding Amount
$192,186.00
Summary
At total hip replacement, there has been a recent trend to use prostheses with a larger ball and liner in the socket. This may decrease the risk of post-operative dislocation, but may also increase the amount of wear, leading to bone loss and loosening of prostheses, which may then require replacement. This project will use a special type of x-ray to determine whether wear and movement of these new prostheses is clinically acceptable, so that they can be used with confidence in patients.
The Risks And Benefits Of Contemporary Total Hip Replacement
Funder
National Health and Medical Research Council
Funding Amount
$493,530.00
Summary
The number of hip replacements undertaken in Australia is steadily increasing. The most common complications of hip replacements are dislocation and loosening due to bone loss around the implant, requiring complex and expensive revision surgery. This study will investigate the incidence of dislocation and, using a new diagnostic imaging technique, the incidence and amount of bone loss around a relatively new prosthetic material, the outcomes of which are not known despite its increasing use.
We will seek to address an important clinical problem in orthpaedics, namely the bone loss that commonly occurs around joint replacement prostheses. Termed peri-prosthetic osteolysis (PO), this bone loss can result in the loosening and ultimate failure and need for revision of the artificial joint components. PO is thought to be caused by the body's reaction to wear particles generated from the articulating surface of the prosthesis. However, it has not previously been possible to accurately exp ....We will seek to address an important clinical problem in orthpaedics, namely the bone loss that commonly occurs around joint replacement prostheses. Termed peri-prosthetic osteolysis (PO), this bone loss can result in the loosening and ultimate failure and need for revision of the artificial joint components. PO is thought to be caused by the body's reaction to wear particles generated from the articulating surface of the prosthesis. However, it has not previously been possible to accurately explore the relationship between prothesis wear and PO, or the progression of PO, because of a lack of techniques to image and measure the volume of PO around metal prosthesis components. We have developed a means to accurately and reproducibly measure the volume of bone loss, using CT, and will do so longitudinally in joint replacement patients to obtain the first information about the progression of PO. New computer based methods will be used concurrently to relate prosthesis wear and migration parameters to PO. Patients who come to surgery for replacement of failed prostheses will be investigated further by analysis of the tissues involved in the bone loss around prostheses. Basic science experiments will seek to understand the underlying causes of PO and the findings will be important in interpreting the clinical results. An animal model will be used to seek approaches to inhibiting the pathological response to wear particles. The significance of these studies is that they will lead to improved outcomes for joint replacement patients, increasing the interval to revision surgery, which is both extremely costly and brings an attendant morbidity and mortality.Read moreRead less
Synchrotron X-ray Assessment Of Airway Surface Physiology For Cystic Fibrosis
Funder
National Health and Medical Research Council
Funding Amount
$778,228.00
Summary
We seek a cure or long-lasting therapy for the fatal airway disease in cystic fibrosis. Disease is caused by a shallow and dehydrated airway surface liquid (ASL), allowing bacteria to infect the lung. We can introduce a corrective gene into mouse airways where it can be effective for over 1 yr, but no fast, accurate and non-invasive measurement exists to test if treatments are successful. We will develop methods using synchrotron light to directly measure ASL depth changes in live mouse airways.