Dynamic In Vivo Size & Shape Measurement Of The Human Upper Airway Using Endoscopic Long-range Optical Coherence Tomogra
Funder
National Health and Medical Research Council
Funding Amount
$184,250.00
Summary
This project will fund the construction of a clinically deployable prototype device to measure changes in upper airway size and shape in patients with obstructive sleep apnoea. We have recently developed and validated a technique based on endoscopic optical coherence tomography (OCT). Preliminary in vivo studies have been performed in the human upper airway and the results published. To our knowledge, this is the only such system world-wide capable of making these important measurements. The tec ....This project will fund the construction of a clinically deployable prototype device to measure changes in upper airway size and shape in patients with obstructive sleep apnoea. We have recently developed and validated a technique based on endoscopic optical coherence tomography (OCT). Preliminary in vivo studies have been performed in the human upper airway and the results published. To our knowledge, this is the only such system world-wide capable of making these important measurements. The technique has wide commercially applicability as it can be used to measure the internal dimensions of any hollow organ system.Read moreRead less
Development Of Quantitative Tools For Assessment Of Regional Cardiac Function By Echocardiography
Funder
National Health and Medical Research Council
Funding Amount
$209,430.00
Summary
The application of ultrasound imaging to the assessment of cardiac function (echocardiography) is an invaluable tool for the assessment of patients with known or suspected cardiac problems. The assessment of contraction in each region of the heart is probably the most important of the reasons for doing this test, as regional function is disturbed in patients with coronary artery disease, which is one of the most common causes of death in Australia. The problem is that this analysis is currently ....The application of ultrasound imaging to the assessment of cardiac function (echocardiography) is an invaluable tool for the assessment of patients with known or suspected cardiac problems. The assessment of contraction in each region of the heart is probably the most important of the reasons for doing this test, as regional function is disturbed in patients with coronary artery disease, which is one of the most common causes of death in Australia. The problem is that this analysis is currently completely subjective, and the reliability of the tool is based upon the availability of an experienced observer. This is particularly a problem in rural Australia, as most specialists with expertise in this modality work in the capital cities, and especially a problem in Queensland, where fewer than half of the population live in the capital. The cardiac imaging group at the University of Queensland have been working in collaboration with GE-Vingmed Ultrasound to develop a quantitative technique for the assessment of regional cardiac function since 1997. This collaboration has been the source of a number of published papers and presentations at international meetings. Our group is considered to be a world leader in the field and our industry partner is clearly the most focused of its competitors in addressing this problem. This submission seeks to address several remaining problems. The data thus far addressed function during stress, when the condition of most patients is similar. Tissue velocities are more variable at rest, and a more sophisticated approach is required to accurately measure the lower velocities in the resting state. This research plan seeks support for the development of a new, high frame-rate acquisition that would facilitate the examination of velocities relative to each other, so that translational motion of the heart does not influence the reading. This new method would then be validated against other techniques for assessing function and disease.Read moreRead less
New Technologies For Hierarchial Shotgun Sequencing Of Recalcitrant And Repetitive DNA
Funder
National Health and Medical Research Council
Funding Amount
$79,750.00
Summary
Many repetitive regions of genomes are difficult to sequence and to assemble. �Sequencing Aided by Mutation� (SAM) is a new sequencing technology, which overcomes many of the difficulties that hinder current sequencing methods. SAM involves forming randomly mutated copies of the target DNA. These copies can then be sequenced and new mathematical tools permit the original target sequence to be revealed from the mutant copies. Here the technology will be developed to aid sequencing of long repetit ....Many repetitive regions of genomes are difficult to sequence and to assemble. �Sequencing Aided by Mutation� (SAM) is a new sequencing technology, which overcomes many of the difficulties that hinder current sequencing methods. SAM involves forming randomly mutated copies of the target DNA. These copies can then be sequenced and new mathematical tools permit the original target sequence to be revealed from the mutant copies. Here the technology will be developed to aid sequencing of long repetitive DNA fragments in genomes.Read moreRead less
Rapid HIV-1 Tropism Testing Using Novel, Soluble Mimics Of The HIV-1 Coreceptors CCR5 And CXCR4
Funder
National Health and Medical Research Council
Funding Amount
$163,426.00
Summary
This proposal seeks to develop an inexpensive assay to determine whether HIV patients will benefit from treatment with new drugs referred to as CCR5 antagonists. These are effective against HIV strains that use the CCR5 coreceptor, therefore a patient�s HIV coreceptor usage must be assessed before commencing therapy. Current assays are complicated, slow and expensive. Using novel, soluble mimics of the coreceptors we will develop an ELISA based test that can be operated using standard equipment.
NaviGAIT: New Software To Simplify Interpretation Of Gait Analysis Data
Funder
National Health and Medical Research Council
Funding Amount
$179,905.00
Summary
NaviGAIT is a new software package to support interpretation of gait analysis data. It is based upon Gait Profiling, a new technique to reduce the complexity of such data. At present data intepretation is restricted to a few expert clinicians. The new software will allow non-expert clinicians to interpret data and hence make gait analysis more accessible, cheaper and more clincally useful. A module of NaviGAIT specifically for children with cerebral palsy will be the first to be developed.
We will conduct a clinical trial of the effectiveness of a continuous auditory display of an anesthetized patient's respiratory status. Expired carbon dioxide monitoring has helped reduce respiratory incidents since its widespread introduction in the late 1980s, but a continuous auditory display of respiratory status may reduce incidents further. We will conduct a clinical trial with 10 anaesthetists of continuous auditory respiratory monitoring. Successful outcome may lead to commercial uptake.
Development Of A PET Detection System Prototype With Depth Of Interaction Capability
Funder
National Health and Medical Research Council
Funding Amount
$360,906.00
Summary
This development project invovles the development of a slim-line Positron Emission Tomogrphy (PET) detection sub-module, the crucial component of PET scanners, that is small and extremely flexible. It is planned to utilize this module in the design of customized new commercial PET scanners ideal for diagnosing human brain and breast disorders. The development will proceed in collaboration with Insight Oceania-ADAC, Sydney. Insight Oceania-ADAC are very excited by the potential applications and f ....This development project invovles the development of a slim-line Positron Emission Tomogrphy (PET) detection sub-module, the crucial component of PET scanners, that is small and extremely flexible. It is planned to utilize this module in the design of customized new commercial PET scanners ideal for diagnosing human brain and breast disorders. The development will proceed in collaboration with Insight Oceania-ADAC, Sydney. Insight Oceania-ADAC are very excited by the potential applications and future markets (Australia and overseas) of the newly developing PET detection sub-modules for dedicated PET scanners. Positron Emission Tomography (PET) is a functional imaging tool, which is able to quantify physiological and biochemical processes in vivo, using short-lived cyclotron-produced radiotracers. PET is emerging as an extremely important diagnostic procedure used in the early detection of cancers, neurological diseases and as an aid in treatment monitoring and drug development. The unique advantage of PET over anatomical imaging techniques, such as X-ray CT and MRI, arises from its ability to measure changes in tumour biology, at the molecular level, prior to anatomical changes in involved tissues, using trace amounts of a radiolabelled compound (radiotracer). The full potential of PET however, is not being completely utilized due to constraints within the current designs of PET scanners. When used to its full potential PET, in principle, would be an excellent diagnostic and treatment monitoring tool for breast cancer, brain tumours and other neurological conditions such as epilepsy, Alzheimer's, Parkinson's disease, post stress disorder, dementia, and depression. Lack of flexibility in current PET scanner designs to date has meant that no commercial human brain or breast imaging scanners exist. Pilot project data proved the feasibility of our new flexible PET detection module design.Read moreRead less