Dynamic In Vivo Size & Shape Measurement Of The Human Upper Airway Using Endoscopic Long-range Optical Coherence Tomogra
Funder
National Health and Medical Research Council
Funding Amount
$184,250.00
Summary
This project will fund the construction of a clinically deployable prototype device to measure changes in upper airway size and shape in patients with obstructive sleep apnoea. We have recently developed and validated a technique based on endoscopic optical coherence tomography (OCT). Preliminary in vivo studies have been performed in the human upper airway and the results published. To our knowledge, this is the only such system world-wide capable of making these important measurements. The tec ....This project will fund the construction of a clinically deployable prototype device to measure changes in upper airway size and shape in patients with obstructive sleep apnoea. We have recently developed and validated a technique based on endoscopic optical coherence tomography (OCT). Preliminary in vivo studies have been performed in the human upper airway and the results published. To our knowledge, this is the only such system world-wide capable of making these important measurements. The technique has wide commercially applicability as it can be used to measure the internal dimensions of any hollow organ system.Read moreRead less
Development Of Quantitative Tools For Assessment Of Regional Cardiac Function By Echocardiography
Funder
National Health and Medical Research Council
Funding Amount
$209,430.00
Summary
The application of ultrasound imaging to the assessment of cardiac function (echocardiography) is an invaluable tool for the assessment of patients with known or suspected cardiac problems. The assessment of contraction in each region of the heart is probably the most important of the reasons for doing this test, as regional function is disturbed in patients with coronary artery disease, which is one of the most common causes of death in Australia. The problem is that this analysis is currently ....The application of ultrasound imaging to the assessment of cardiac function (echocardiography) is an invaluable tool for the assessment of patients with known or suspected cardiac problems. The assessment of contraction in each region of the heart is probably the most important of the reasons for doing this test, as regional function is disturbed in patients with coronary artery disease, which is one of the most common causes of death in Australia. The problem is that this analysis is currently completely subjective, and the reliability of the tool is based upon the availability of an experienced observer. This is particularly a problem in rural Australia, as most specialists with expertise in this modality work in the capital cities, and especially a problem in Queensland, where fewer than half of the population live in the capital. The cardiac imaging group at the University of Queensland have been working in collaboration with GE-Vingmed Ultrasound to develop a quantitative technique for the assessment of regional cardiac function since 1997. This collaboration has been the source of a number of published papers and presentations at international meetings. Our group is considered to be a world leader in the field and our industry partner is clearly the most focused of its competitors in addressing this problem. This submission seeks to address several remaining problems. The data thus far addressed function during stress, when the condition of most patients is similar. Tissue velocities are more variable at rest, and a more sophisticated approach is required to accurately measure the lower velocities in the resting state. This research plan seeks support for the development of a new, high frame-rate acquisition that would facilitate the examination of velocities relative to each other, so that translational motion of the heart does not influence the reading. This new method would then be validated against other techniques for assessing function and disease.Read moreRead less
Commercial Testing Of A Physiologically Based Theory Of Oscillatory Brain Electrical Activity In Anaesthesia Monitoring
Funder
National Health and Medical Research Council
Funding Amount
$191,165.00
Summary
While the mechanisms of local anaesthesia are comparatively well known, the mechanisms whereby anaesthetics impair consciousness remain unresolved. This lack of understanding has implications in our ability to monitor the level of anaesthesia while anaesthetic consumption and side effects are minimized. Despite this a number of devices have been developed that attempt to monitor the depth of anaesthesia by quantifying the brains electrical activity. All monitors analyse the activity using a set ....While the mechanisms of local anaesthesia are comparatively well known, the mechanisms whereby anaesthetics impair consciousness remain unresolved. This lack of understanding has implications in our ability to monitor the level of anaesthesia while anaesthetic consumption and side effects are minimized. Despite this a number of devices have been developed that attempt to monitor the depth of anaesthesia by quantifying the brains electrical activity. All monitors analyse the activity using a set of criteria that have been developed by trial and error. The research of Dr David Liley and his team, at Swinburne University of Technology, has resulted in a detailed understanding of the physiological mechanisms that generate brain electrical activity. The outcome is a practical means to carry out a System Based Analysis of Brain Electrical Response (SABER). In 2004, Dr Liley began working with Cortical Dynamics, a company involved in the commercialisation of medical devices. This collaboration incorporated the SABER system into a new prototype device called the Brain Anaesthesia Response (BAR) monitor. In 2004 Dr Liley and Associate Professor Kate Leslie collaborated in a trial, at the Royal Melbourne Hospital to test the sensitivity of the SABER system in quantifying the effect that various levels of nitrous oxide have on measures of anaesthetic depth. The Australian and New Zealand College of Anaesthetists supported this study. Initial results obtained with sevoflurane and 3 levels of nitrous oxide showed the ability to differentiate between conscious and unconscious states of patients based on two physiological characterizations of higher brain dynamic state. The next step requires commercial product validation (ie scale up) and further clinical efficacy in testing beta stage depth of anaesthesia BAR units. Completion of this will help the technology move away from a low volume prototype system into a commercially applicable device.Read moreRead less
Se015: A Developmental Drug For The Treatment Of Brain Tumours
Funder
National Health and Medical Research Council
Funding Amount
$304,206.00
Summary
Primary malignant brain tumors are amongst the most lethal forms of human cancers with median survival for these patients being only around 1 year. In spite of the advent of new targeted therapies for some cancers the prognosis for these patients remains dismal. Worldwide, more than 95% of all people who contract the disease will die of it. This is because there are no effective therapies and all current treatments are only palliative, seeking to lesson the distressing suffering associated with ....Primary malignant brain tumors are amongst the most lethal forms of human cancers with median survival for these patients being only around 1 year. In spite of the advent of new targeted therapies for some cancers the prognosis for these patients remains dismal. Worldwide, more than 95% of all people who contract the disease will die of it. This is because there are no effective therapies and all current treatments are only palliative, seeking to lesson the distressing suffering associated with disease progression. Nearly all therapies that have shown some efficacy in treating cancer, such as chemotherapy and radiation have a mode of action whereby they attempt to kill cancer cells by inflicting enough damage to the cancer cells that they induce them to commit cell suicide, a process called apoptosis. Unfortunately, cancer cells can become resistant to these therapies by activating the cells' own signaling pathways that normally block apoptosis. One of the key pathways that has been implicated in resistance to apoptosis in human cancers is the PI3K-Akt pathway. This pathway is overactivated in many advanced human tumors, particularly in glioblastoma. We have discovered a compound, Se015, which can effecitively block this pathway in brain cancer cells and is able to dramatically improve the effectiveness of both chemotherapy and radiation in killing these cells. We have confirmed the efectiveness of Se015 in preliminary animal models of brain cancer, where we have shown that Se015 demonstrated no noticeable toxicity and was active when taken orally. We now need to explore further the molecular mode of action of Se015, as well as complete our animal studies with the eventual aim of initiating a small trial of Se015 in glioblastoma patients in the forseeable future.Read moreRead less
Newborn babies are at risk of becoming short of oxygen during delivery and sustaining brain damage. Seizures may cause further damage to the brain because they release damaging chemicals or make extra energy demands on the brain that cannot be met. To detect seizures, it is necessary to measure the EEG, the tiny electrical signals from the brain. We are proposing to automatically detect and count seizures, building upon 8 years of fundamental EEG signal processing research work we have undertake ....Newborn babies are at risk of becoming short of oxygen during delivery and sustaining brain damage. Seizures may cause further damage to the brain because they release damaging chemicals or make extra energy demands on the brain that cannot be met. To detect seizures, it is necessary to measure the EEG, the tiny electrical signals from the brain. We are proposing to automatically detect and count seizures, building upon 8 years of fundamental EEG signal processing research work we have undertaken. We anticipate that the product will be of major commercial interest. We will further explore what is a rapidly expanding marketplace and ensure we maximize the commercial return on this product.Read moreRead less
A Motion Correction Technique For Accurate PET/CT Brain Imaging In Paediatric And Dementia Patients
Funder
National Health and Medical Research Council
Funding Amount
$190,450.00
Summary
PET-CT imaging is a vital tool in the diagnosis and management of patients with brain disorders including dementia, epilepsy and cancer. However images are often distorted by patient motion, particularly in demented and paediatric patients. The CI has recently developed a motion tracking and correction method to derive images nearly free of motion effects. This aim of this project is to evaluate its impact on image quality in a variety of patients referred for PET- CT brain investigations.
Rapid, Cost-effective, Diagnosis And Monitoring Of Multiple Sclerosis By Novel Multifocal Evoked Potential Methods
Funder
National Health and Medical Research Council
Funding Amount
$152,463.00
Summary
A new technology for concurrently stimulating both eyes, and recording thousands of responses from the brain, will be tested for its effectiveness in diagnosing and tracking progression in Multiple Sclerosis (MS), and the degree to which it complements Magnetic Resonance Imaging (MRI). Our understanding of MS has changed in recent years. It is now recognised to have two phases: an initial inflammatory phase, and a secondary progressive phase. The progressive phase produces the inexorable increas ....A new technology for concurrently stimulating both eyes, and recording thousands of responses from the brain, will be tested for its effectiveness in diagnosing and tracking progression in Multiple Sclerosis (MS), and the degree to which it complements Magnetic Resonance Imaging (MRI). Our understanding of MS has changed in recent years. It is now recognised to have two phases: an initial inflammatory phase, and a secondary progressive phase. The progressive phase produces the inexorable increasing disability of MS. MS only affects about 0.04% of Australians but the early onset of MS, the high cost of medication, and the prolonged period of disability, mean that the cost to Australia is about $2 billion pa. MRI quantifies the inflammatory phase well but is poorly correlated with the debilitating secondary progression. The common treatments for MS target the inflammatory phase but not the causes of secondary progression, which are unknown. Current diagnostic methods mean diagnosis can take years, meaning that patients can be denied treatment for some time. The applicants have published experiments on 50 MS patients and 27 normal subjects using a variant of the new method. Not only has it shown high diagnostic accuracy, but the new method seems to provide data on the progressive phase, suggesting strongly that it is complementary to MRI. The new method is also much cheaper to set up and run than MRI and so could provide cost-effective means for monitoring patient condition and testing new drugs that are effective against the progressive phase. The applicants have considerable experience commercialising diagnostic technologies, and are currently working with an Australian company developing new diagnostic hardware. That hardware has been adapted to perform the presently proposed experiments. Overall it is reasonable to assume that positive outcomes will be translated into economic and health benefits for Australians.Read moreRead less
A Device For Simultaneous Continuous Acquisition Of EEG And MRI
Funder
National Health and Medical Research Council
Funding Amount
$179,401.00
Summary
We aim to further develop a world-leading method we invented that facilitates the simultaneous, continuous acquisition of the electroencephalogram (EEG - electrical brain waves measured at the scalp) and functional Magnetic Resonance Imaging (fMRI - images the location of brain activity throughout the brain). Combining the two permits non-invasive imaging of human brain function with the exquisite temporal resolution of EEG and the high spatial resolution and brain coverage afforded by fMRI.
The NanoNautilus : A Breakthrough In The Successful Treatment Of Strokes And Other Cerebrovascular Diseases
Funder
National Health and Medical Research Council
Funding Amount
$187,212.00
Summary
Strokes are one of the biggest killers of Australians and are becoming increasingly so every year. Bleeding from the brain involves extremely delicate and dangerous medical treatments. The development of NanoNautilus [TM]---a remote-controlled steerable microcatheterusing world-first miniaturization technology---will revolutionise current practises and greatly reduce the current risk with medical intervention.
Development Of A PET Detection System Prototype With Depth Of Interaction Capability
Funder
National Health and Medical Research Council
Funding Amount
$360,906.00
Summary
This development project invovles the development of a slim-line Positron Emission Tomogrphy (PET) detection sub-module, the crucial component of PET scanners, that is small and extremely flexible. It is planned to utilize this module in the design of customized new commercial PET scanners ideal for diagnosing human brain and breast disorders. The development will proceed in collaboration with Insight Oceania-ADAC, Sydney. Insight Oceania-ADAC are very excited by the potential applications and f ....This development project invovles the development of a slim-line Positron Emission Tomogrphy (PET) detection sub-module, the crucial component of PET scanners, that is small and extremely flexible. It is planned to utilize this module in the design of customized new commercial PET scanners ideal for diagnosing human brain and breast disorders. The development will proceed in collaboration with Insight Oceania-ADAC, Sydney. Insight Oceania-ADAC are very excited by the potential applications and future markets (Australia and overseas) of the newly developing PET detection sub-modules for dedicated PET scanners. Positron Emission Tomography (PET) is a functional imaging tool, which is able to quantify physiological and biochemical processes in vivo, using short-lived cyclotron-produced radiotracers. PET is emerging as an extremely important diagnostic procedure used in the early detection of cancers, neurological diseases and as an aid in treatment monitoring and drug development. The unique advantage of PET over anatomical imaging techniques, such as X-ray CT and MRI, arises from its ability to measure changes in tumour biology, at the molecular level, prior to anatomical changes in involved tissues, using trace amounts of a radiolabelled compound (radiotracer). The full potential of PET however, is not being completely utilized due to constraints within the current designs of PET scanners. When used to its full potential PET, in principle, would be an excellent diagnostic and treatment monitoring tool for breast cancer, brain tumours and other neurological conditions such as epilepsy, Alzheimer's, Parkinson's disease, post stress disorder, dementia, and depression. Lack of flexibility in current PET scanner designs to date has meant that no commercial human brain or breast imaging scanners exist. Pilot project data proved the feasibility of our new flexible PET detection module design.Read moreRead less