A New Non-invasive Diagnostic Technique Based On Detection Of Exhaled Respiratory Pathogens.
Funder
National Health and Medical Research Council
Funding Amount
$179,300.00
Summary
We developed a special collection mask and showed that the breath of people with colds or flu contains a tiny amount of virus. Currently, diagnostic samples are collected by putting a tube into the airways - this is very uncomfortable. Our masks may provide a new and more comfortable way to diagnose lung infections. We want to build better masks and ways to detect viruses and bacteria to test out this method. This may create a new test that will improve diagnosis and treatment.
Oxidised Mannan As A Novel Adjuvant To Vaccinate Against Mucosal Infections
Funder
National Health and Medical Research Council
Funding Amount
$150,000.00
Summary
Most pathogens invade via the mucosal surfaces. However, current vaccines, which are delivered by injection, are poor at inducing mucosal immunity. An ideal vaccine would comprise a defined protein antigen combined with a suitable adjuvant which could be administered intranasally or orally. Protective antigens have been defined for a number of infections but suitable adjuvants have been elusive. We showed that mannan, a complex carbohydrate from yeast, oxidatively linked to protein antigens can ....Most pathogens invade via the mucosal surfaces. However, current vaccines, which are delivered by injection, are poor at inducing mucosal immunity. An ideal vaccine would comprise a defined protein antigen combined with a suitable adjuvant which could be administered intranasally or orally. Protective antigens have been defined for a number of infections but suitable adjuvants have been elusive. We showed that mannan, a complex carbohydrate from yeast, oxidatively linked to protein antigens can be used as an adjuvant for mucosal IgA and other classes of antibody. Given to mice intranasally, antigen coupled to mannan markedly enhanced production of IgA, IgG1 and IgG2a in serum, and IgA in lung, tears, vaginal secretions, saliva and gut. We have confirmed this for a number of known or putative protective antigens. In addition, both the Th1 and Th2 arms of the lymphocyte response were activated. We have demonstrated protection against P. gingivalis (cause of periodontitis and associated with premature birth and cardiovascular disease) in a mouse lesion model. However, before commercial interests will commit themselves, we need to demonstrate protection against viral infections and in other sites like lungs and gut. Three infection models where IgA has been shown to protect are already set up and can realistically produce results in 1 year. 1. Rotavirus is the major cause of severe infantile gastroenteritis in humans and animals world wide. The latest (live) vaccine was withdrawn because of side effects. We have established a model with Simian rotavirus causing an acute self-limiting disease in infant mice. Adult females will be immunised with mannan linked to killed virus preparations, mated and passive protection of their offspring will be assessed. Preliminary evidence links rotavirus infection with the onset of type 1 diabetes. If this is confirmed, there will be an opportunity to test the vaccine against diabetes. 2. Influenza: IN infection of mice with flu virus is a well established model. Mice will be immunised IN with mannan coupled to haemagglutinin-neuraminidase purified from egg-grown virus. They will be challenged IN with influenza virus and virus titrated in lung homogenates. Neutralising antibody in serum and lung washings will essayed. 3. Respiratory syncytial virus: RSV is the commonest cause of bronchiolitis and pneumonia in infants for which there have been unsuccessful attempts to produce a vaccine. F and G membrane glycoproteins have been shown to protect mice against IN infection, and they will be used coupled to mannan to vaccinate mice against intranasal challenge.Read moreRead less
Dynamic In Vivo Size & Shape Measurement Of The Human Upper Airway Using Endoscopic Long-range Optical Coherence Tomogra
Funder
National Health and Medical Research Council
Funding Amount
$184,250.00
Summary
This project will fund the construction of a clinically deployable prototype device to measure changes in upper airway size and shape in patients with obstructive sleep apnoea. We have recently developed and validated a technique based on endoscopic optical coherence tomography (OCT). Preliminary in vivo studies have been performed in the human upper airway and the results published. To our knowledge, this is the only such system world-wide capable of making these important measurements. The tec ....This project will fund the construction of a clinically deployable prototype device to measure changes in upper airway size and shape in patients with obstructive sleep apnoea. We have recently developed and validated a technique based on endoscopic optical coherence tomography (OCT). Preliminary in vivo studies have been performed in the human upper airway and the results published. To our knowledge, this is the only such system world-wide capable of making these important measurements. The technique has wide commercially applicability as it can be used to measure the internal dimensions of any hollow organ system.Read moreRead less
Mechanical Mobility Of The Thorax For Continuous Determination Of Lung Gas Volume
Funder
National Health and Medical Research Council
Funding Amount
$165,000.00
Summary
Percussion is a valuable clinical method for physical examination of parts of the body. A sharp tap (impulsive force) is applied to the body wall and the sound radiated in response is observed. This sound may be dull (over liver) or stony dull (pleural effusion), or resonant (over normal lung) or hyper-resonant (over bowel). While the variation in radiated sound is not fully understood, it is apparent that the presence of gas, which is highly compliant, increases mobility of the overlying tissue ....Percussion is a valuable clinical method for physical examination of parts of the body. A sharp tap (impulsive force) is applied to the body wall and the sound radiated in response is observed. This sound may be dull (over liver) or stony dull (pleural effusion), or resonant (over normal lung) or hyper-resonant (over bowel). While the variation in radiated sound is not fully understood, it is apparent that the presence of gas, which is highly compliant, increases mobility of the overlying tissue and allows it to resonate; where the sub-tissue is largely fluid, tissue mobility is low and the percussive sound is dull. Percussion is useful for examining the adult chest and lung, but cannot for example be applied in infant intensive care as only limited impulsive force can be used, and the adult finger, which is both a coupling device and sounding board, is too large. As well, percussion requires skill and quiet conditions. Accordingly, we developed a device to measure mobility of the chest and other tissues in real time. The VibroPulse applies a known low-level force to the body surface and records the resultant velocity induced in the surface. The force is generated by a vibrating mass set in motion by an electromagnetic motor driven by pseudo-random noise. Tissue mobility, defined as velocity-force, is derived simultaneously across the frequency range, providing an easily interpreted quantitative output unaffected by ambient noise. This proposal has two aims we can achieve in 1 year: (1) to continue evaluating VibroPulse sensitivity to tissue composition, using symmetrical percussive sites on the human chest and abdomen that are dull on one side and resonant on the other, and the chest of anaesthetised animals with experimentally induced pneumothorax and lung collapse, two life-threatening conditions for which percussion is a key diagnostic method, and (2) to engineer a small device from our bulky prototype that is suitable for clinical use, in infants and adults.Read moreRead less
Novel Silver Nanoparticle Coatings For The Prevention Of Infection Of Biomedical Implants And Devices
Funder
National Health and Medical Research Council
Funding Amount
$455,305.00
Summary
This project targets infections associated with implants and biomedical devices such as catheters, pacemaker leads, knee and hip implants, by the development and evaluation of coatings delivering antibacterial silver ions. The novel coating method is more uniform and reproducible and can be applied to a wide range of biomedical implants and devices. The novel coatings will be tested for antimicrobial effectiveness and safety using cell and tissue culture methods and animal clinical studies.
Development And Application Of A Pressure-sensing Electropalatograph For The Assessment And Treatment Of Speech Disorder
Funder
National Health and Medical Research Council
Funding Amount
$200,750.00
Summary
A multidisciplinary team of researchers aim to develop a unique, advanced, computer-based speech device that speech pathologists can use to assess and treat a variety of speech disorders. The device will record the location, timing and pressure of tongue contacts against the roof of the mouth (palate) during speech using innovative sensors embedded in an artificial plate placed over the roof of the mouth. State-of-the-art 3D graphics will be used to display tongue-to-palate contacts to both spee ....A multidisciplinary team of researchers aim to develop a unique, advanced, computer-based speech device that speech pathologists can use to assess and treat a variety of speech disorders. The device will record the location, timing and pressure of tongue contacts against the roof of the mouth (palate) during speech using innovative sensors embedded in an artificial plate placed over the roof of the mouth. State-of-the-art 3D graphics will be used to display tongue-to-palate contacts to both speech pathologist and patient.Read moreRead less
The Development Of A Cross-strain And Cross-subtype Pre Pandemic Influenza Vaccine Using Savine Technology
Funder
National Health and Medical Research Council
Funding Amount
$159,500.00
Summary
The flu vaccines in use today work by inducing antibodies to surface proteins. Flu causes disease every year but occasionally a new strain arises that is distincly differnet from previous strains and can cause wides spread disease and deaths worldwide. Our new approach is to increase the level of T cells that can recognise and kill flu infected cells from all flu strains.
Development Of Novel Methods For Non-invasive Measurement Of Cardiac Output And Lung Volume During Anaesthesia
Funder
National Health and Medical Research Council
Funding Amount
$257,970.00
Summary
In Australia approximately 2 million anaesthetic procedures are performed annually. Approximately one patient in 20,000 dies during or shortly after an anaesthetic from complications related to the anaesthetic itself, and as many as one in 170 suffers severe complications. Mortality and severe morbidity are often ultimately associated with lack of oxygen in the tissues. Oxygen is transported from the lungs to the tissues by the blood. The oxygen content of arterial blood is monitored by pulse ox ....In Australia approximately 2 million anaesthetic procedures are performed annually. Approximately one patient in 20,000 dies during or shortly after an anaesthetic from complications related to the anaesthetic itself, and as many as one in 170 suffers severe complications. Mortality and severe morbidity are often ultimately associated with lack of oxygen in the tissues. Oxygen is transported from the lungs to the tissues by the blood. The oxygen content of arterial blood is monitored by pulse oximetry during every anaesthetic, but blood flow is not. Cardiac output is measured in only a very small proportion of anaesthetised patients using intravenous catheters that pass through the heart to the lungs. This procedure is invasive and is associated with significant morbidity and mortality. At present there is no easy way to monitor cardiac output non-invasively during anaesthesia. Our proposed research project, currently underway in conjunction with an industrial partner, is aimed at the development of a reliable, rapidly repeating, non-invasive method for monitoring total cardiac output and lung volume in every patient who has an anaesthetic. The purpose of the new monitor is to ensure that potential problems with oxygen supply to the tissues are detected and corrected promptly. Our new monitoring technique is computer-controlled, can function without intervention by the anaesthetist and has very few side-effects. It can be added to any anaesthetic machine. Such a measurement technique is likely to have an impact on anaesthesia similar to that of pulse oximetry in the 1980's, and, if suitably adapted, is likely to find applications in other fields, such as intensive care, sports medicine, the respiratory function laboratory and in veterinary medicine.Read moreRead less
Ocular Implant For The Treatment Of Bacterial Endophthalmitis
Funder
National Health and Medical Research Council
Funding Amount
$483,446.00
Summary
We seek to develop an ocular implant for the treatment of bacterial endophthalmitis. The implant will be a small device that can be administered directly to the affected ocular cavity to release an antibiotic in a controlled manner to clear any infection. The implant will erode and leave no residue. It will be produced from a novel drug-polymer conjugate technology that allows polymer devices that comprise >50% drug to be made.