Tissue Engineering of Human Heart Valve Grown In Vitro. Tissue engineering (TE) of heart valves is a new approach to cultivate a functional heart valve from human autologous cells. This innovative study aims to develop the technology to transplant cells onto a 3D biocompatible valve scaffold that is capable of mimicking native valve. The work proposed is a ground breaking study that will encompass development of a new biomaterial, manufacture of scaffolds using the Fused Deposition Modelling ra ....Tissue Engineering of Human Heart Valve Grown In Vitro. Tissue engineering (TE) of heart valves is a new approach to cultivate a functional heart valve from human autologous cells. This innovative study aims to develop the technology to transplant cells onto a 3D biocompatible valve scaffold that is capable of mimicking native valve. The work proposed is a ground breaking study that will encompass development of a new biomaterial, manufacture of scaffolds using the Fused Deposition Modelling rapid prototyping process, hemodynamic optimisation and in vitro cell culture. This will advance our knowledge in cellular and scaffold technologies and may ultimately lead to the development of a TE heart valve.Read moreRead less
Intelligent Freeform Bio-fabrication for Customised Anatomical Structures for Reconstructive Surgery. This project contributes towards the ARC priority goal on advanced materials and frontier technologies by developing an intelligent freeform biofabrication facility to produce accurate anatomical biocompatible replica structures and implants for reconstructive surgery. The products, produced from patient's CT or MRI scan data, will contribute to complex surgical procedure planning and patient ed ....Intelligent Freeform Bio-fabrication for Customised Anatomical Structures for Reconstructive Surgery. This project contributes towards the ARC priority goal on advanced materials and frontier technologies by developing an intelligent freeform biofabrication facility to produce accurate anatomical biocompatible replica structures and implants for reconstructive surgery. The products, produced from patient's CT or MRI scan data, will contribute to complex surgical procedure planning and patient education. The proposed facility will be based on multifunctional freeform fabrication process supported by intelligent software tools and database of biocompatible materials. The prospective outcomes are likely to have an excellent commercial and patenting potential that may help Australia become a leader in biomanufacturing technology.Read moreRead less
Fluid dynamics and mechanical stress of tissue heart valves. Major problems with thrombo-embolic complications and leaflet failure and calcification still exist with bioprosthetic valves. Valves fabricated from polyether urethanes are efficient and can offer more resistance to calcification. No complete study on the haemodynamics and structure interactions is found in literature. Moreover, todate the effect of aortic wall motion on the blood flow has never been examined. A complete holistic ap ....Fluid dynamics and mechanical stress of tissue heart valves. Major problems with thrombo-embolic complications and leaflet failure and calcification still exist with bioprosthetic valves. Valves fabricated from polyether urethanes are efficient and can offer more resistance to calcification. No complete study on the haemodynamics and structure interactions is found in literature. Moreover, todate the effect of aortic wall motion on the blood flow has never been examined. A complete holistic approach to simulataneuosly simulating the fluid dynamics, the valve motion and the stress in a synthetic Polyether urethane valve is proposed. Cell adhesion study will also be carried out. The findings may yield to new insights into valve research.Read moreRead less
Rapid Development of Biocompatible Stent Grafts for Aortic Aneurysms. Weakening of the aorta may cause an aneurysm. The present technique of its treatment involves replacing the weakened portion of the aorta with a synthetic graft. Failure of this treatment often occurs due to non-compatibility of the stent graft with natural aorta. One possible reason for this is a mismatch between elastic natural aorta and the non-elastic artificial graft. The core component of our project is the selection and ....Rapid Development of Biocompatible Stent Grafts for Aortic Aneurysms. Weakening of the aorta may cause an aneurysm. The present technique of its treatment involves replacing the weakened portion of the aorta with a synthetic graft. Failure of this treatment often occurs due to non-compatibility of the stent graft with natural aorta. One possible reason for this is a mismatch between elastic natural aorta and the non-elastic artificial graft. The core component of our project is the selection and development of a suitable biomaterial and optimization of the stent design based on hemodynamics flow analysis and its fabrication with the Fused Deposition Modelling (FDM) process.Read moreRead less
Understanding the biomechanical effects of fixation strategies to improve the technology of fracture management. Severe limb trauma is the leading cause of disability to people of wage-earning age, and 150,000 Australians are hospitalised with fractures each year. Beyond the direct costs to the nation of $1000 million annually, temporary and permanent loss of limb functionality have a significant impact on productivity and quality of life. The computational models developed in this project will ....Understanding the biomechanical effects of fixation strategies to improve the technology of fracture management. Severe limb trauma is the leading cause of disability to people of wage-earning age, and 150,000 Australians are hospitalised with fractures each year. Beyond the direct costs to the nation of $1000 million annually, temporary and permanent loss of limb functionality have a significant impact on productivity and quality of life. The computational models developed in this project will address critical gaps in the knowledge of fracture healing and the influence of different fixation devices. The project outcomes will provide a basis for tailoring fixation technologies for more reliable outcomes and minimised risk of non-union and complications, and thereby reducing physical impairment and the socio-economic burden of fractures.Read moreRead less
In Vitro Study of Hemodynamic Stresses and Endothelialization of Artificial Coronary Arteries. Restenosis (recurrence of the disease) is a major problem in the case of patients undergoing artificial artery by-pass surgery. Ideally the design for manufacturing the scaffold for cell adhesion of the artery should factor in hemodynamic forces and optimised geometry to withstand the hemodynamic stresses and other forces. This project aims to investigate the material for manufacturing the artificial a ....In Vitro Study of Hemodynamic Stresses and Endothelialization of Artificial Coronary Arteries. Restenosis (recurrence of the disease) is a major problem in the case of patients undergoing artificial artery by-pass surgery. Ideally the design for manufacturing the scaffold for cell adhesion of the artery should factor in hemodynamic forces and optimised geometry to withstand the hemodynamic stresses and other forces. This project aims to investigate the material for manufacturing the artificial artery using Fused Deposition Modeling and to develop methods for the establishment of endothelium on the artificial artery, concluding a restenosis-free solution for by-pass surgery. The knowledge gained through this work would be applicable to the design of other prosthetic devices.Read moreRead less
Direct measurement of the kinetics of trans-femoral amputee gait during activities of daily living. This project involves the use of a novel technique to accurately measure the loads placed upon the lower limbs of above-knee amputees. Included in the subject group will be a number of amputees fitted with an artificial leg fitted directly into the bone. The ability to monitor a range of activities is possible by the use of a wireless telemetry system. The outcomes of this work will benefit ampute ....Direct measurement of the kinetics of trans-femoral amputee gait during activities of daily living. This project involves the use of a novel technique to accurately measure the loads placed upon the lower limbs of above-knee amputees. Included in the subject group will be a number of amputees fitted with an artificial leg fitted directly into the bone. The ability to monitor a range of activities is possible by the use of a wireless telemetry system. The outcomes of this work will benefit amputees around the world, as well as clinicians and companies who are dedicated to developing significant improvements in the functional abilities of subjects who have suffered amputation.Read moreRead less
Innovative approach to design a new osseointegrated implant for transfemoral amputees with better resistance to fractures. Transfemoral amputees fitted with an osseointegrated implant are experiencing numerous valuable benefits compare to their previous method conventional attachment. However, 40% of them present an early loosening of the implant or ruptures of the abutment. These problems are related to the load regime acting on the fixation system during post-operative rehabilitation and daily ....Innovative approach to design a new osseointegrated implant for transfemoral amputees with better resistance to fractures. Transfemoral amputees fitted with an osseointegrated implant are experiencing numerous valuable benefits compare to their previous method conventional attachment. However, 40% of them present an early loosening of the implant or ruptures of the abutment. These problems are related to the load regime acting on the fixation system during post-operative rehabilitation and daily life activities. In this project, the direct measurement of the actual load applied on the abutment during:
· the load bearing exercises is essential to refine the post- operative rehabilitation program.
· every-day activities is crucial to improve the design and
testing of the implants and abutments.Read moreRead less
Design and Fabrication of an Engineered Bone Graft System (EBGS) by combining a composite scaffold and growth factor delivery system. The lifetime risk for long bone fractures in Caucasians over the age of 50 is 17% for women and 6% for men. The prevalence of age-related fractures - and with it higher mortality rates due to complications following bone fractures - is therefore bound to increase over the coming decades. There is clearly a great need for therapies that take age-related changes in ....Design and Fabrication of an Engineered Bone Graft System (EBGS) by combining a composite scaffold and growth factor delivery system. The lifetime risk for long bone fractures in Caucasians over the age of 50 is 17% for women and 6% for men. The prevalence of age-related fractures - and with it higher mortality rates due to complications following bone fractures - is therefore bound to increase over the coming decades. There is clearly a great need for therapies that take age-related changes into consideration, in particular the diminishing capacity of bone to heal with age. In an effort to address the therapeutic challenges of providing bone grafts, we aim to mesh two leading-edge technologies to design and fabricate an Engineered Bone Graft System (EBGS) system. Read moreRead less
Linkage Infrastructure, Equipment And Facilities - Grant ID: LE0668506
Funder
Australian Research Council
Funding Amount
$150,000.00
Summary
A Multi-Axis Biomaterials Testing Facility. Damage to bones and joints, due to injury or diseases such as osteoporosis and arthritis, is a major cause of disability and cost to the nation. Australia's ageing population contributes not only to an increasing incidence of such conditions, but also to more patients out-living implants such as replacement joints. In 2001-2, Australia spent over $800 million on joint replacement. Because over 11% of procedures are revisions of failed implants, even sm ....A Multi-Axis Biomaterials Testing Facility. Damage to bones and joints, due to injury or diseases such as osteoporosis and arthritis, is a major cause of disability and cost to the nation. Australia's ageing population contributes not only to an increasing incidence of such conditions, but also to more patients out-living implants such as replacement joints. In 2001-2, Australia spent over $800 million on joint replacement. Because over 11% of procedures are revisions of failed implants, even small improvements in implant life represent significant cost savings. By accurately simulating conditions within the body, this biomechanical testing facility will lead to new developments in implant designs and materials, in turn improving quality of life, productivity and treatment costs.Read moreRead less