Measurement and Prediction of Vulnerable Plaque Formation and Rupture. The major health problem of atherosclerosis, leading to large numbers of deaths from heart attacks and strokes worldwide, will be studied by a multidisciplinary team. Better understanding of how the disease evolves and its earlier detection will arise from this project, which will use synchrotron imaging and supercomputer prediction.
Noval design of a Bi-Ventricular Assist Device (BVAD) Centrifugal Heart Pump as an Implantable Total Artificial Heart. In Australia, 40%(50,797) of all deaths each year are related to heart disease and accounted for 12% (A$4Billion) of total recurrent health expenditure. This innovative research aims at developing a single biventricular assist device (BVAD) driven by a magnetically suspended double-sided centrifugal pump impeller. Current techniques require two implantable devices, thus preventi ....Noval design of a Bi-Ventricular Assist Device (BVAD) Centrifugal Heart Pump as an Implantable Total Artificial Heart. In Australia, 40%(50,797) of all deaths each year are related to heart disease and accounted for 12% (A$4Billion) of total recurrent health expenditure. This innovative research aims at developing a single biventricular assist device (BVAD) driven by a magnetically suspended double-sided centrifugal pump impeller. Current techniques require two implantable devices, thus preventing smaller patients from access to BVAD technology. The expected outcomes will be a significantly small and compact device and provide an alternative to open-heart transplantation, thus helping to alleviate the demand on donor hearts, as well as the strain on the Australian Heath Care System caused by cardiovascular disease.Read moreRead less
Approximately 7% of elderly men have an abdominal aortic aneurysm (AAA) and AAA rupture usually results in death. This research aims to improve the limitations in AAA risk assessment. Currently, the maximum diameter determines if the aneurysm is at risk of rupture. However, many small AAAs rupture and 75% of larger ones never burst. Using computer models generated from medical imaging can substantially improve the understanding of rupture risk, therefore, saving lives and reducing health care co ....Approximately 7% of elderly men have an abdominal aortic aneurysm (AAA) and AAA rupture usually results in death. This research aims to improve the limitations in AAA risk assessment. Currently, the maximum diameter determines if the aneurysm is at risk of rupture. However, many small AAAs rupture and 75% of larger ones never burst. Using computer models generated from medical imaging can substantially improve the understanding of rupture risk, therefore, saving lives and reducing health care costs.Read moreRead less
Optimizing blood flow in stented arteries: a fluid mechanics approach incorporating optical coherence tomography. Constriction in coronary arterial blood flow is a leading cause of death in Australia. Insertion of stents can rectify this problem but potentially lead to further complications. This project will use medical imaging data to construct computer models to study blood flow and particle motions in coronary arteries and improve stent designs.
The development of particle-depleted regions in dense suspensions of neutrally buoyant particles. We aim to measure the spatial variation of fluid speed and particle speed, and of particle concentration, across and along a pipe into which has been introduced a mixture of said particles and fluid. This problem has significance in mechanical and chemical engineering wherever particle/fluid mixtures are flowing. The expected outcomes are recognition of a major contribution to world research, as w ....The development of particle-depleted regions in dense suspensions of neutrally buoyant particles. We aim to measure the spatial variation of fluid speed and particle speed, and of particle concentration, across and along a pipe into which has been introduced a mixture of said particles and fluid. This problem has significance in mechanical and chemical engineering wherever particle/fluid mixtures are flowing. The expected outcomes are recognition of a major contribution to world research, as well as technological applications; one that motivates us is the blood shear in the bearings of a revolutionary Australian blood pump for cardiac assist that avoids both pivots and magnetic suspension for the single moving part.Read moreRead less
Optimising haemodynamics in complex stented arteries. This project aims to optimise the hemodynamics (blood flow) in coronary arteries with high curvatures and bifurcations. Experience has shown that the build-up of plaque — and the resulting occlusion of blood flow — tends to occur in these complex arterial regions. The most common therapeutic strategy is the insertion of a stent to prop open the artery. However, the nature of the geometry often leads to post-stenting complications such as rest ....Optimising haemodynamics in complex stented arteries. This project aims to optimise the hemodynamics (blood flow) in coronary arteries with high curvatures and bifurcations. Experience has shown that the build-up of plaque — and the resulting occlusion of blood flow — tends to occur in these complex arterial regions. The most common therapeutic strategy is the insertion of a stent to prop open the artery. However, the nature of the geometry often leads to post-stenting complications such as restenosis and thrombosis, ultimately resulting in negative outcomes. In this project, advanced research methods from fluid dynamics and optimisation and control will be used to potentially minimise these highly undesirable effects.Read moreRead less
Tissue Engineering of Human Heart Valve Grown In Vitro. Tissue engineering (TE) of heart valves is a new approach to cultivate a functional heart valve from human autologous cells. This innovative study aims to develop the technology to transplant cells onto a 3D biocompatible valve scaffold that is capable of mimicking native valve. The work proposed is a ground breaking study that will encompass development of a new biomaterial, manufacture of scaffolds using the Fused Deposition Modelling ra ....Tissue Engineering of Human Heart Valve Grown In Vitro. Tissue engineering (TE) of heart valves is a new approach to cultivate a functional heart valve from human autologous cells. This innovative study aims to develop the technology to transplant cells onto a 3D biocompatible valve scaffold that is capable of mimicking native valve. The work proposed is a ground breaking study that will encompass development of a new biomaterial, manufacture of scaffolds using the Fused Deposition Modelling rapid prototyping process, hemodynamic optimisation and in vitro cell culture. This will advance our knowledge in cellular and scaffold technologies and may ultimately lead to the development of a TE heart valve.Read moreRead less
Fluid dynamics and mechanical stress of tissue heart valves. Major problems with thrombo-embolic complications and leaflet failure and calcification still exist with bioprosthetic valves. Valves fabricated from polyether urethanes are efficient and can offer more resistance to calcification. No complete study on the haemodynamics and structure interactions is found in literature. Moreover, todate the effect of aortic wall motion on the blood flow has never been examined. A complete holistic ap ....Fluid dynamics and mechanical stress of tissue heart valves. Major problems with thrombo-embolic complications and leaflet failure and calcification still exist with bioprosthetic valves. Valves fabricated from polyether urethanes are efficient and can offer more resistance to calcification. No complete study on the haemodynamics and structure interactions is found in literature. Moreover, todate the effect of aortic wall motion on the blood flow has never been examined. A complete holistic approach to simulataneuosly simulating the fluid dynamics, the valve motion and the stress in a synthetic Polyether urethane valve is proposed. Cell adhesion study will also be carried out. The findings may yield to new insights into valve research.Read moreRead less
Determination of Conductivity Values for Anisotropic Tissue. Well established mathematical models governing the electrical potential in biological tissue can be combined with measurements of the electric potential on the surface of the tissue to provide insight into subsurface tissue damage. However, before such observations can be convincingly accepted, reliable values for the tissue conductivity must be obtained. The aim of this project is to develop mathematical techniques to calculate the co ....Determination of Conductivity Values for Anisotropic Tissue. Well established mathematical models governing the electrical potential in biological tissue can be combined with measurements of the electric potential on the surface of the tissue to provide insight into subsurface tissue damage. However, before such observations can be convincingly accepted, reliable values for the tissue conductivity must be obtained. The aim of this project is to develop mathematical techniques to calculate the conductivity values so that one can apply the equations to solve problems of potential distribution and proceed to accurately simulate electrical potential distributions in damaged tissue. More accurate and reliable conductivity values will allow a better understanding of the way electric current moves through the heart which, in turn, will result in more efficient defibrillators and better diagnosis of abnormal function.Read moreRead less
Rapid Development of Biocompatible Stent Grafts for Aortic Aneurysms. Weakening of the aorta may cause an aneurysm. The present technique of its treatment involves replacing the weakened portion of the aorta with a synthetic graft. Failure of this treatment often occurs due to non-compatibility of the stent graft with natural aorta. One possible reason for this is a mismatch between elastic natural aorta and the non-elastic artificial graft. The core component of our project is the selection and ....Rapid Development of Biocompatible Stent Grafts for Aortic Aneurysms. Weakening of the aorta may cause an aneurysm. The present technique of its treatment involves replacing the weakened portion of the aorta with a synthetic graft. Failure of this treatment often occurs due to non-compatibility of the stent graft with natural aorta. One possible reason for this is a mismatch between elastic natural aorta and the non-elastic artificial graft. The core component of our project is the selection and development of a suitable biomaterial and optimization of the stent design based on hemodynamics flow analysis and its fabrication with the Fused Deposition Modelling (FDM) process.Read moreRead less