ORCID Profile
0000-0001-8566-3548
Current Organisations
Deakin University
,
Korea Atomic Energy Research Institute
Does something not look right? The information on this page has been harvested from data sources that may not be up to date. We continue to work with information providers to improve coverage and quality. To report an issue, use the Feedback Form.
Publisher: Elsevier BV
Date: 06-1997
Publisher: IOP Publishing
Date: 07-1997
Publisher: Elsevier BV
Date: 09-2023
Publisher: Elsevier BV
Date: 09-2008
Publisher: Optica Publishing Group
Date: 03-1997
DOI: 10.1364/AO.36.001482
Abstract: Titanium oxide thin film, fabricated with tetraisopropyltitanate and oxygen by electron cyclotron resonance-plasma-enhanced chemical vapor deposition, is investigated as a potential candidate for the antireflective layer in KrF excimer laser (248-nm) lithography. The oxygen flow-rate dependence of the optical properties such as the refractive index (n) and the extinction coefficient (k) of the film at the 248-nm wavelength has been characterized, and the films with the expected combinations of n and k values for the antireflective layer have been deposited. Simulation results indicate that reflectance values of less than 4% and as low as 1.2% can be reached at the interface between the photoresist and the film postulating the structures of the photoresist/300-A TiO(x) film/c-Si substrate and the W-Si substrate, respectively, by selected proper combinations of n and k values. Moreover the reflectance can be further reduced to almost zero by changing the film thickness. Thus it is found that titanium oxide thin films can be used as the bottom antireflective layer in KrF excimer laser lithography.
Publisher: Oxford University Press (OUP)
Date: 17-06-2022
Abstract: Wearable cameras offer an innovative way to discover new insights into the lived experience of people with cardiovascular conditions. Wearable cameras can be used alone or supplement more traditional research methods, such as interviews and participant observations. This paper provides an overview of the benefits of using wearable cameras for data collection and outlines some key considerations for researchers and clinicians interested in this method. We provide a case study describing a study design using wearable cameras and how the data were used.
Publisher: Elsevier BV
Date: 10-2004
Publisher: BMJ
Date: 06-2022
DOI: 10.1136/OPENHRT-2021-001949
Abstract: This review aimed to compare the relative effectiveness of different exercise-based cardiac rehabilitation (ExCR) delivery modes (centre-based, home-based, hybrid and technology-enabled ExCR) on key heart failure (HF) outcomes: exercise capacity, health-related quality of life (HRQoL), HF-related hospitalisation and HF-related mortality. Randomised controlled trials (RCTs) published through 20 June 2021 were identified from six databases, and reference lists of included studies. Risk of bias and certainty of evidence were evaluated using the Cochrane tool and Grading of Recommendations Assessment, Development and Evaluation, respectively. Bayesian network meta-analysis was performed using R. Continuous and binary outcomes are reported as mean differences (MD) and ORs, respectively, with 95% credible intervals (95% CrI). One-hundred and thirty-nine RCTs (n=18 670) were included in the analysis. Network meta-analysis demonstrated improvements in VO 2 peak following centre-based (MD (95% CrI)=3.10 (2.56 to 3.65) mL/kg/min), home-based (MD=2.69 (1.67 to 3.70) mL/kg/min) and technology-enabled ExCR (MD=1.76 (0.27 to 3.26) mL/kg/min). Similarly, 6 min walk distance was improved following hybrid (MD=84.78 (31.64 to 138.32) m), centre-based (MD=50.35 (30.15 to 70.56) m) and home-based ExCR (MD=36.77 (12.47 to 61.29) m). Incremental shuttle walk distance did not improve following any ExCR delivery modes. Minnesota living with HF questionnaire improved after centre-based (MD=−10.38 (−14.15 to –6.46)) and home-based ExCR (MD=−8.80 (−13.62 to –4.07)). Kansas City Cardiomyopathy Questionnaire was improved following home-based ExCR (MD=20.61 (4.61 to 36.47)), and Short Form Survey 36 mental component after centre-based ExCR (MD=3.64 (0.30 to 6.14)). HF-related hospitalisation and mortality risks reduced only after centre-based ExCR (OR=0.41 (0.17 to 0.76) and OR=0.42 (0.16 to 0.90), respectively). Mean age of study participants was only associated with changes in VO 2 peak. ExCR programmes have broader benefits for people with HF and since different delivery modes were comparably effective for improving exercise capacity and HRQoL, the selection of delivery modes should be tailored to in iduals’ preferences.
Location: Korea, Republic of
Location: United States of America
No related grants have been discovered for Byung-Hyuk Jun.